D C C S S O a O R R L w E E M M p T T P P O R R a L L p R I I E E A A H r V V l N N A N N i T T r E Universal input 85-305VAC Features 4W PCB mount package <75mW No load power consumption AC/DC Converter Ultra low profile, compact size Regulated -40C to +85C Operating temperature Continuous SCP, OCP, OVP Converter RAC04-GA IEC/EN/UL60950 & EN60335-1 certified, EN55032 Class A Description 4 Watt 3 The RAC04-GA series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board Single level industrial applications. They feature universal AC input voltage range, regulated and short-circuit -proof isolated DC outputs, low standby power consumption and -40C to +85C operating temperature Output range. The RAC04-GA have a built-in Class A / FCC Part 15 EMC filter, are certified to IEC/EN/UL60950-1 and EN60335 and are certified to IEC/EN/UL62368 and EN61558 safety standards and come with a EMC Class A three year warranty. Selection Guide Part Input Output Output Efficiency Max. Capacitive (1) (2) Number Voltage Range Voltage Current typ Load VAC VDC mA % F RAC04-05SGA 85-305 5 800 72 1500 RAC04-09SGA 85-305 9 440 77 1000 RAC04-12SGA 85-305 12 330 78 500 RAC04-24SGA 85-305 24 170 80 150 2+ RoHS REACH ERP compliant compliant compliant 10 from 10 On Request RAC04-3.3SGA 85-305 3.3 1210 70 2000 RAC04-15SGA 85-305 15 270 78 200 E196683 Notes: Note1: Efficiency is tested at 230VAC and full load at +25C ambient CERTIFIED EN-60335-1 Note2: Max. Cap. Load is tested at nominal input and full resistive load UL60950-1 certified IEC/EN60950-1 certified UL62368-1 certified IEC/EN62368-1 certified Model Numbering EN61558-1 certified EN61558-2-16 certified EN60335-1 certified CB Report RAC04- SGA nom. Output Power EMC Class A Single nom. Output Voltage Ordering Examples: RAC04-12SGA 12Vout Single Output EMC Class A www.recom-power.com REV.: 6/2020 PA-1 O O a P P E a C C S R R n O O Y M M n U D D c O O U U t O C C C C e E E y T T R R H s S SRAC04-GA AC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi-type 85VAC 305VAC (3,4) Input Voltage Range nom. Vin = 230VDC 120VDC 430VDC 115VAC 85mA Input Current 230VAC 55mA 115VAC 10A Inrush Current cold start at 25C 230VAC 20A No load Power Consumption 75mW Input Frequency Range AC Input 45Hz 65Hz Minimum Load 0% 115VAC 0.55 Power Factor 230VAC 0.42 Start-up Time 115VAC, 230VAC 30ms 1s 115VAC 5ms Hold-up time 230VAC 40ms Internal Operating Frequency 100% load at nominal Vin 65kHz 5Vout 100mVp-p 9Vout 120mVp-p 0C to 85 C 12Vout 150mVp-p 24Vout 240mVp-p (5) Output Ripple and Noise 20MHz BW 5Vout 200mVp-p 9Vout 250mVp-p -30 C to 0 C 12Vout 250mVp-p 24Vout 300mVp-p Notes: Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to Line Derating Note5: Measurements are made with a 12 twisted pair-wire with a 0.1F and 10F parallel capacitor across output (low ESR) Efficiency vs. Load RAC04-05SGA RAC04-12SGA 100 100 90 90 80 80 70 70 60 60 50 50 115Vin 115Vin 40 230Vin 40 230Vin 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % www.recom-power.com REV.: 6/2020 PA-2 Efficiency % Efficiency %