D C C S S a O O R R L w E E M M p T T P P O R R a L L p R I I E E A A H r V V l N N A N N i T T E r Wide input range 85-264VAC Features Standby mode optimized PSU (ENER Lot 6) Ultra-high efficiency over entire load range AC/DC Converter Operating temperature range: -40C to +85C Regulated Class II installations (without FG) EMC compliant without external components Converter RAC15-KRAC No load power consumption 40mW typ. Description 15 Watt 3 The RAC15-K series are highly efficient PCB-mount power conversion modules with ultra-low 2 x 1 energy losses especially in light load conditions, making them a benchmark for always-on and standby mode operations, which are typically coming along with IoT and smart applications. The power supply Single Output units cover worldwide mains input range of 85VAC up to 264VAC and come with international safety certifications for industrial, AV and ITE as well as household standards. These AC/DC modules operate in a temperature range of -40C to +85C and offer fully protected single or dual outputs as well as EMC class B compliance without the need of any external components. Selection Guide Part Input Output Output Efficiency Max. Capacitive (1) (2) Number Voltage Range Voltage Current typ Load VAC VDC mA % F RAC15-05SK 85-264 5 3000 84 10000 RAC15-12SK 85-264 12 1250 86 8000 22++ ERP RoHSRoHS REACHREACH compliant RAC15-15SK 85-264 15 1000 86 1500 compliantcompliant compliantcompliant 10 from 1010 from 10 LOT6 RAC15-24SK 85-264 24 615 85 1000 Notes: CERTIFIED Note1: Efficiency is tested at 230VAC input and constant resistive load at +25C ambient EN-60335-1 E224736 Note2: Max Cap Load is tested at nominal input and full resisitive load Model Numbering IEC/EN62368-1 certified UL62368-1 certified RAC15- SK CAN/CSA-C22.2 No. 62368-1-14 certified IEC/EN60335 certified nom. Output Power Single IEC/EN61558-1 certified Output Voltage IEC/EN61558-2-16 certified IEC/EN61204-3 compliant EN55032/14 compliant EN55024 compliant Ordering Examples: CB Report RAC15-05SK 5Watt 5Vout Single Output Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi type nom. Vin = 230VAC 85VAC 230VAC 264VAC (3,4) Input Voltage Range 120VDC 370VDC 115VAC 400mA Input Current 230VAC 350mA 115VAC 20A Inrush Current cold start at +25C 230VAC 40A continued on next page www.recom-power.com REV.: 5/2020 PA-1 O O a P P E a C C S R R n O O Y M M n U D D O O c U U t C C O C C e E E y T T R R H s S SRAC15-K AC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. No Load Power Consumption 230VAC 40mW 0.5W 0.3W ErP Lot 6 Standby Mode Conformity (Output Load Input Power = 1.0W 0.7W Capability) 2.0W 1.6W Input Frequency Range AC Input 47Hz 63Hz Minimum Load 0% 115VAC 0.6 Power Factor 230VAC 0.5 Start-up Time 150ms Rise Time 40ms 115VAC 15ms Hold-up Time 230VAC 90ms Internal Operating Frequency 100kHz (5) Output Ripple and Noise 20MHz BW 100mVp-p Notes: Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to Line Derating Note5: Measurements are made with a 1.0F MLCC across output (low ESR) Efficiency vs. Load RAC15-05SK RAC15-12SK 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 115VAC 115VAC 20 20 230VAC 230VAC 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % REGULATIONS Parameter Condition Value Output Accuracy 2.0% typ. Line Regulation low line to high line 1.0% typ. (6) Load Regulation 10% to 100% load 1.0% typ. 25% load step change 4.0% max. Transient Response recovery time 500s typ. Notes: Note6: Operation below 10% load will not harm the converter, but specifications may not be met continued on next page www.recom-power.com REV.: 5/2020 PA-2 Efficiency % Efficiency %