60W Class II AC-DC LED Power Supply Features LIGHTLINE Constant Current Operation AC/DC-Converter Power Factor Corrected LED DRIVER Universal Input Voltage Range with 5 year Warranty User Adjustable Current Limit (/OF) Thermal Feedback Dimming (/TOF) Waterproof Enclosure (/IP67) cUL/UL8750 Certified, CE Marked Class 2 Power Unit UL1310 High Efficiency 60 Watt PFC Long 5 Year Warranty Single Output Description The RACD60 is a compact universal input voltage 60W constant current power module suitable for driving high power LEDs. The RACD60 series have active power factor correction, universal input voltage range and are fully protected against output short circuit, overload and over-temperature. Three versions are available: a low cost open-frame with either internal (/OF) or external user-adjustable current limit (/TOF), and a sealed IP67 potted version (/IP67) with factory set output currents for outdoor or high humidity applications. The LED driver is a class II power supply with CSA, UL and CE certifications and comes with a five year warranty. Selection Guide Part Output Output Factory Set Efficiency Output Number Voltage Range Current Range Current (230VAC) Power (min - max)** (min - max) Limit Typ. Range RACD60-700* 38 - 54V 700 - 1100mA 0.7A 89% 27-60W RACD60-1050* 38 - 54V 700 - 1100mA 1.0A 89% 27-60W E340696 RACD60-1400* 21 - 28V 1400 - 2140mA 1.4A 89% 30-60W RoHS RACD60-2100* 21 - 28V 1400 - 2140mA 2.1A 89% 30-60W 2011/65/EU 6/6 RACD60-2400* 17 - 24V 2150 - 2500mA 2.4A 87% 30-60W UL 8750 Certified RACD60-4200* 11 - 13.5V 3570 - 4200mA 4.2A 85% 40-60W cUL 8750 Certified* * use suffix /OF for open frame version (standard) - output current limit adjustable with on-board trimmer EN 61347 Certified * use suffix /TOF for open frame version with thermal feedback - output current limit externally adjustable. * use suffix /IP67 for waterproof potted version - fixed output currents only ** adjustable output current range at potentiometer (only /OF types) ordering examples: RACD60 RACD60-700/OF= open frame, adustable current limit preset to 700mA. RACD60-1050/TOF=open frame,1050mA, adjustable 700-1050mA with ext. voltage or PWM signal. RACD60-1400/IP67 = enclosed IP67 waterproof, non-adjustable 1400mA output. Note: all currents within range are available - use RACD60-xxxx/IP67 where xxxx is the desired fixed current * except 700mA/1100mA Versions e.g. RACD60-900/IP67 = enclosed IP67 waterproof, non-adjustable 900mA output. Specifications (typical at 25C and after warm up time unless otherwise specified ) Input Voltage Derating (Ta=25C) Input Voltage Range All Versions 90-264VAC Rated Power 60 Watts max. Input Frequency Range All Versions 50/60 Hz Power Factor Correction Full Load, 115VAC/230VAC > 0.9 THD Full Load, 115VAC 17% max. Full Load, 230VAC 20% max. Input Current (full load) 115VAC/230VAC 0.8A / 0.4A max. Inrush Current (cold start) 115VAC/230VAC 25A / 50A max. Leakage Current 230VAC/63Hz <0.7mA max. Input Fuse Built-in 3.15A Slow Blow ) % Output Current Accuracy Full load 5% Note: Output Current Adjust Preset Potentiometer (/OF) 75% to 100% approx. All LED Drivers may not be used without a External Voltage (/TOF) load. They must be switched on the primary Line Voltage Regulation LL to HL at Full Load 4% typ. side only. Noncompliance may damage the Load Voltage Regulation 60% to 100% Load 5% typ. LED or reduce its lifetime. Minimum Load Current see table Operating Frequency All Versions 65kHz typ. Refer to Application Notes continued on next Page L-50 REV: 0/2015 www.recom-power.com 8 2 RACD60 RACD60 LIGHTLINE AC/DC-Converter Series (typical at 25C and after warm up time unless otherwise specified ) Specifications Efficiency at Full Load see Selection Guide Isolation Voltage (60Hz RMS) input to output 3.75kVAC / 1 minute input to filter ground 1880VAC / 1 minute output to filter ground 500VAC / 1 minute Temperature Coefficient All Versions 0.02%/C typ. Overload Protection All Versions 105% typ. Short Circuit Protection Continuous, Hiccup, Automatic Restart Open Circuit Output Voltage 4200mA 19VDC (Zener Diode Clamp) 2400mA 25VDC Typical Values 2100mA/1400mA 29VDC 1050mA/700mA 55VDC Output Current Adjust (/TOF only) External Voltage (1-10V) 10.5V max. External PWM (10V) 300Hz max. Operating Temperature Range free air convection, with derating -30C to +70C (refer to derating graphs) Case temperature (/IP67) 85C max. Storage Temperature Range -40C to +85C Humidity non-condensing 95% RH max. Environmental Protection Open Frame (/OF, /TOF) Indoor Use Only Potted Version (/IP67) IP67 PCB Material Plastic Resin with Fibreglass (UL94V-0) Weight Open Frame (/OF, /TOF) 165g Potted Version (/IP67) 200g Packing Quantity 1pc EMC EN 55015, EN61347-1, EN61347-2-13 Harmonics Certified to meet EN 61000-3-2 (Class C, Full load) and EN 61000-3-3 MTBF (using MIL-HDBK-217F, 25C) 583 x 10 hours Safety Standards LED Lighting Safety Report: E34696 UL8750 LED Lighting Safety (Canada) Report: E34696 cUL8750 Class 2 Power Supply Safety Report: E34696 UL1310 Extra Low-Voltage Class 2 Output Report: E34696 CSA C22.2 No. 223-M91 LED equipment for lighting application Report: E34696 CSA C22.2 No. 250.13-12 CE LVD Directive -all models EN61347 Input/Output Connections /OF Pin Header (suitable matching connector JST VHR or similar) . /IP67 340mm Cable 20mm /TOF Output Current Adjustment ( 4 5 / The /TOF offers the possibility to derate the output current with an external voltage or PWM signal. 4 5 / Thermal feedback derating is an effective way to reduce the ( LED current at high temperatures to avoid over-stressing 4 5 / 4 5 / the LED. 6 :E 0 G 8 6 621 6 6: ) % 8<B 5 -..J 4. : 0 2 - 01 -( 5.J 7 : - : ( 7 7 & 2: ( ( & 95B + + 4. ( -.5. ) 7 -5 & -..= % 5B * -. 7 ( I -,33=+ 5 35 5 55 45 95 A5 K5 -.5 :7 ( : %B * www.recom-power.com REV: 0/2015 L-51 , 9