Household, medically and ITE certified Features Class II installations (without FG) AC/DC Converter IP68 waterproof encapsulation Long life components, rugged module Regulated Energy Efficiency Level VI Converter Cable and connector modifications on request RACM18-ER/W Description 18 Watt The RACM18-ER/W series comprises highly reliable power conversion modules in a potted IP68 Wired certified, waterproof encapsulation to fit into flush mount wall installations. All versions are covered by multiple certifications for household, medical and ITE safety standards as well. With a certified operation up to 5000m altitude and a temperature range from -20C up to +80C the modules Round Shape are designed to power sanitary, healthcare, smart building, automation and household applications. Without the need for any external components they are ready to connect and forget. Single Output Selection Guide Part Input Output Output Efficiency (1) (2) Number Voltage Range Voltage Current typ. VAC VDC A % (3) RACM18-05SER/W 90-264 5 2.5 81 (3) RACM18-12SER/W 90-264 12 1.5 82 (3) RACM18-24SER/W 90-264 24 0.75 83.5 Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25C ambient IP68 R C US REBA VEBA Model Numbering 2MOPP 280VAC RACM18- SER/W IEC/EN60950-1 certified (3) UL60950-1 certified Output Power Wired Connection ANSI/AAMI ES60601-1 certified Output Voltage Single IEC/EN60601-1 certified IEC/EN60335-1 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified Notes: IEC/EN60601-1-2 certified Note3: Other connection types on reqeuest EN55024/32 certified EN55014-1 (-2) certified CISPR32 certified IEC60529 certified www.recom-power.com REV.: 2/2018 MED-1RACM18-ER/W AC/DC Converter Series Specifications (measured ta= 25C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi type Input Voltage Range 90VAC 230VAC 264VAC 115VAC 500mA Input Current 230VAC 150mA 115VAC 24A Inrush Current 230VAC 46A No load Power Consumption 40mW 75mW Input Frequency Range 47Hz 63Hz Minimum Load 0% 0.46 Power Factor 115VAC 180ms Start-up Time 230VAC 200ms Rise Time 115VAC/230VAC 15ms 115VAC 15ms Hold-up Time 230VAC 65ms Internal Operating Frequency 100% load at nominal Vin 100kHz 20MHz BW 140mVp-p Output Ripple and Noise Efficiency vs. Load RACM18-12SER/W RACM18-24SER/W 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 85VAC 85VAC 20 20 115VAC 115VAC 10 10 230VAC 230VAC 264VAC 264VAC 0 0 0 25 50 75 100 0 25 50 75 100 Output Load % Output Load % REGULATIONS Parameter Condition Value Output Accuracy 3.0% max. Line Regulation low line to high line 1.0% max. Load Regulation 0% to 100% load 1.0% max. Transient Response 100% load step change 3.0% max. continued on next page www.recom-power.com REV.: 2/2018 MED-2 Efficiency % Efficiency %