8W DIP24 Package ECONOLINE Features 2KVDC and 3kVDC Isolation Options DC/DC-Converter 2:1 and 4:1 Versions with 3 year Warranty Continuous Short Circuit Protection Regulated (power limiting) Converters Synchronous Rectification on 3.3, 5V outputs Full SMD internal design Through Hole or SMD Pinning Options Remote Control Pin Efficiency to 87% 8 Watt The REC8-xxxxSRW/DRW-series offer single and dual regulated outputs in a DIP24 package with DIP24 & SMD Description 2kV or 3kV isolation options and are suitable for higher power industrial or medical applications. Remote on/off control is standard and SMD pinning is offered with the /SMD option. Single & Dual The converters can deliver 150% rated power for short periods of time to cope with applications with large capacitive loads or high start up currents. Output Selection Guide Part Input Output Output Efficiency Max. Number Voltage Voltage Current Capacitive (VDC) (VDC) (mA) (%) Load REC8-xx3.3SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 3.3 1600 83-85 2200F REC8-xx05SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 5 1600 85-87 2200F REC8-xx12SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 12 666 84-86 470F REC8-xx15SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 15 533 84-86 220F RoHS 2011/65/EU REC8-xx05DRW/H*/A/M 9-18, 18-36, 36-75 5 800 84 1000F 6/6 E-224736 REC8-xx12DRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 12 333 84-86 220F REC8-xx15DRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 15 267 84-86 100F EN-60950-1 Certified REC8-xx3.3SRWZ/H*/A/M 9-36, 18-75 3.3 1600 84 2200F UL-60950-1 Certified EN-60601-1 Certified REC8-xx05SRWZ/H*/A/M 9-36, 18-75 5 1600 86 2200F REC8-xx12SRWZ/H*/A/M 9-36, 18-75 12 666 85 470F REC8-xx15SRWZ/H*/A/M 9-36, 18-75 15 533 85 220F REC8 REC8-xx05DRWZ/H*/A/M 9-36, 18-75 5 800 83 1000F REC8-xx12DRWZ/H*/A/M 9-36, 18-75 12 333 85 220F REC8-xx15DRWZ/H*/A/M 9-36, 18-75 15 267 85 100F * Standard is /H2 for 2kVDC isolation, 2:1 4:1 use /H3 for 3kVDC Isolation (not SMD) xx = 4.5-9Vin = 05, xx = 9-36Vin = 24, * add suffix /SMD for SMD package, e.g. xx = 9-18Vin = 12, xx = 18-75Vin = 48 REC8-2405SRW/H2/A/M/SMD xx = 18-36Vin = 24, xx = 36-75Vin = 48 Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up) A Input Voltage Range 2:1 & 4:1 Input Filter PI Network Output Voltage Accuracy 1.5% max. Line Voltage Regulation (VL to VH at full load) 0.5% max. Load Voltage Regulation Single 0.5% max. (25% to 100% full load ) Dual 1.2% max. Cross Regulation (100%: 25% to 100% full load ) 5% max. Output Ripple and Noise (with 100n output capacitor and 20MHz BW) 50mVp-p max. Start-up time 300ms typ. Operating Frequency (Full Load) 330kHz typ. Efficiency at Full Load see Selection Guide Minimum Load 0% Refer to Application Notes continued on next page E-160 REV: 0/2015 www.recom-power.comREC8 REC8-S DRW(Z)/H*/A/M ECONOLINE DC/DC-Converter Series Specifications cont. (measured at T = 25C, nominal input voltage, full load and after warm-up) A Input Surge Voltage (100ms max.) 5V Input 15VDC Derating-Graph 12V Input 36VDC 24V Input 50VDC (Ambient Temperature) 48V Input 100VDC 2:1 Converters Isolation Voltage H2-Suffix and SMD (tested for 1 second) 2000VDC (rated for 1 minute**) 1000VAC / 60Hz H3-Suffix (tested for 1 second) 3000VDC I ** O (rated for 1 minute**) 1500VAC / 60Hz Isolation Capacitance 1200pF typ. I , A , Isolation Resistance 1 G min. Overload Protection 150% typ. Short Circuit Protection Continuous, Auto Restart Operating Temperature Range 4:1 -40C to +71C (see Graph) 2:1- Vin=5V -40C to +71C (see Graph) (free air convection) 2:1 - All Others -40C to +85C (see Graph) . Remote On/Off DC/DC ON Open or 3.5V<Vr<12V DC/DC OFF Short or 0V<Vr<1.2V Storage Temperature Range -55C to +105C 4:1 Converters Temperature Coefficient 0.05% max. Relative Humidity 95% RH max. I Case Material Nickel Plated Metal with Non-Conductive Base Thermal Impedance Natural convection 12C/W Maximum Case Temperature 100C Vibration 10-55Hz, 2G, 30mins along X,Y & Z Package Weight 18g Packing Quantity 15 pcs per Tube 3 MTBF (+25C) using MIL-HDBK 217F 1200 x 10 hours . Detailed Information see 3 Application Notes chapterMTB (+71C) using MIL-HDBK 217F >300 x 10 hours Certifications EN General Safety Report: SPCLVD1211033-2 EN60950-1:2006 +A12:2011 UL General Safety Report: E224736 UL 60950-1 1st Ed. **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. C22.2 No. 60950-1-03 For further details, please refer to our Application Notes. EN Medical Safety Report: MDD12060585 + RM1206085 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment Typical Characteristics REC8-1205SRW/H2/A/M (/SMD) REC8-1212SRW/H2/A/M (/SMD) 3 + +4 % & ) * , 3 + +4 , 7 , * / . . . . . / * + 7 , * , Note: Refer to Application Notes for EMC Class B Filter suggestion www.recom-power.com REV: 0/2015 E-161 3 + +4 3 + +4