Compliant with DALI Standard Features (IEC62386 Part 102 & Part 206) LIGHTLINE Screw-less Connectors, Easy to Install DALI DALI-Converter AC/DC Selectable Output for DC 0-10V / DC 1-10 / PWM Converter Built-in Relay to Turn ON/OFF Driver with 5 year Warranty Completely (Zero Standby Current) Over Voltage and Short Circuit Protection Description The RELI-DA01/R is a DALI to analog control signal interface which is compliant with the DALI IEC62386 (1) standard and listed on the agDALI website.. The output is selectable between 0-10V and 1-10V or PWM and 1.6 Watt is compatible with all RECOM dimmable LED drivers as well as other manufacturers products. The output can control several LED drivers, allowing the lighting in a whole room or office to be dimmed with just one DALI DALI- address. A built-in relay can be used to switch off the LED drivers under software control to give zero no-load consumption. The interface is universal AC powered (110VAC, 230VAC or 277VAC). Converter Selection Guide Part Input Power DALI Bus DALIDimming Number Voltage Consumption Power Consumption Standard Output (VAC) (W) (mA) IEC62386 RELI-DA01/R 90-290 1.6 typ. 2 max. Part-102 DC 0-10V Part-206 DC 1-10V (1) or PWM RoHS 2011/65/EU Note1: PWM output is not included in the IEC62386 standard 6/6 IEC 62386-102 Compliant Specifications (measured at T = 25C and nominal input voltage) A IEC 62386-206 Compliant Input Voltage Range 90-290VAC, 50/60Hz EN55015 Certified Power Consumption 1.6W typ. / 3W max. EN61347 Certified EN61547 Certified DALI Bus Current Consumption 2mA max. Suitable Electric Wire 22 AWG - 16 AWG PWM Frequency 500Hz typ. RELI-DA01/R PWM High Level Voltage 9.5VDC min. / 10VDC typ. / 10.5VDC max. PWM Low Level Voltage 0VDC typ. PWM Output Current Sourcing (mA) -60mA min. / 60mA max. DC 0/1-10V Output Accuracy 3% DC Output Current Sourcing (mA) -5mA min. / 60mA max. DALI Standard IEC62386 Part-102 & Part-206 Short Circuit Protection (Dimming Output) cont., current limited to 240mA Over Voltage Protection (DALI connector) 24V Zener Diode clamp Operating Temperature Range Ambient Temperature -20 to +40C (free air convenction) Case Temperature 46C Relay Switch 1 Channel, 2A cont. / 70A inrush handling IP Rating IP20 Dimensions 150 x 40 x 28mm Weight 100g 10% Safety Standards (100-240VAC) Report: P201311017 EN61347-1, 2nd Edition EN61347-2-11, 1st Edition EMC Emmission Report: HA140050 IEC61000-3-2, 3 EN55015 EMC Immunity IEC61000-4-2,3,4,5,6, 8, 11 Class A EN61547 MTBF (+25C) using MIL-HDBK 217F 200 x 10 hours min. Refer to Application Notes L-72 REV: 0/2015 www.recom-power.comRELI-DA01/R RELI-DA01/R LIGHTLINE AC/DC-Converter Series Typical Characteristics DALI Declaration for Factory Variables (for Part 102) Variable Default Value Reset Value Range of Validity Actual Dim Level 254 254 0, Min Level - Max Level Power on Level 254 254 0 - 255 (Mask) System Failure Level 254 254 0 - 255 (Mask) Min Level Physical Min Level Physical Min Level Physical Min Level - Max Level Max Level 254 254 Min Level - 254 Fade Rate 7 (45 steps/s) 7 (45 steps/s) 1-15 Fade Time 0 (no fade) 0 (no fade) 0-15 Short Address 255 (Mask) no change 0-63 255 (Mask) Search Address FF FF FF FF FF FF 00 00 00 - FF FF FF Random Address FF FF FF FF FF FF 00 00 00 - FF FF FF Group 0-7 0000 0000 (no group) 0000 0000 (no group) 0 - 255 Group 8-15 0000 0000 (no group) 0000 0000 (no group) 0 - 255 Group 0-15 255 (Mask) 255 (Mask) 0 - 255 (Mask) Status Information 1xx0 xxxx 0x10 0xxx 0 - 255 Version Number 1 no change Factory-defined x = actual value depend on the operation status DALI Declaration for Factory Variables (for Part 206) Variable Default Value Reset Value Received Command Range of Validity Dimming Curve 0 No change 0 0-1 (2 - 255 reserved) Converter Features 0011 a101 No change 0011 a101 53 61 Failure Status 0000 0000 No change 0000 0000 0 - 255 Converter Status 0000 0000 No change 0000 0000 0 - 255 Extended Version Number 1 No change 1 Factory-defined Device Type 5 No change 5 Factory-defined Physical min Level 1 No change 1 1-253 a = 0 Relay Function dissabled a = 1 Relay Function enabled DALI Command Set The RELI-DA01/R has been accepted by agDALI as conforming to the DALI standard for Control Gear (IEC 62386-102) and Device Type 5 (IEC 62386-206). It supports all relevant commands of the defined command set. Command Number Command Name Function - DIRECT ARC POWER set directly the light level 0 OFF switch off the light 1 UP dim up the light 2 DOWN dim down the light 5 RECALL MAX recall the maximum light level 6 RECALL MIN recall the minimum light level Not supported commands include the QUERY LAMP FAILURE and the QUERY LAMP POWER ON. Additionally the features to disable the Relay Switch, set the output to PWM, change the PWM from active- high to active-low are additional and not tested by DALI (refer to the RELI-DA01/R instruction manual). www.recom-power.com REV: 0/2015 L-73