Reinforced insulation for 250VAC working voltage Features Clearance and creepage distance: 8mm DC/DC Converter 5kVAC I/P to O/P 2MOPP isolation 2A patient leakage current Regulated Industry standard pinout Converter 2:1 and 4:1 wide input range REM10 Description 10 Watt The REM10 series of medical grade regulated DC/DC converters features reinforced 5kVAC/1 minute 2:1 & 4:1 isolation with low 2A leakage and are 60601-1 3rd Ed. certified for 250VAC continuous working. The compact DIP24 package offers tightly regulated single and dual outputs, even under no-load DIP24 conditions. The outputs are short circuit and overload protected. The converters are available in two different pinning options and optionally with an external control pin for standby consumption as low as 12.5mW. The converters are fully certified to CB, IEC/EN and ANSI/AAMI standards and carry UL mark. Single and Dual Selection Guide Output Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. Load VDC VDC mA % F (3,4) REM10-xx3.3S/ 5 / 12 / 24 / 48 3.3 2500 80 / 83 / 83 / 82.5 3000 (3,4) REM10-xx05S/ 5 / 12 / 24 / 48 5 2000 84 / 85.5 / 86.5 / 86.5 2500 (3,4) REM10-xx12S/ 5 / 12 / 24 / 48 12 830 86.5 / 88 / 89 / 89 430 (3,4) REM10-xx15S/ 5 / 12 / 24 / 48 15 670 87 / 89 / 89 / 89 350 (3,4) REM10-xx24S/ 5 / 12 / 24 / 48 24 416 85.5 / 89 / 89 / 88. 125 (3,4) REM10-xxx05D/ 5 / 12 / 24 / 48 5 1000 83 / 84 / 85 / 85 1440 (3,4) REM10-xx12D/ 5 / 12 / 24 / 48 12 416 85.5 / 89 / 89 / 88 250 ERP compliant (3,4) REM10-xx15D/ 5 / 12 / 24 / 48 15 333 86.5 / 88 / 89 / 88 180 (3,4) REM10-xx3.3SW/ 24 / 48 3.3 2500 83 / 82.5 3000 (3,4) REM10-xx05SW/ 24 / 48 5 2000 86.5 / 86.5 2500 (3,4) REM10-xx12SW/ 24 / 48 12 830 89 / 89 430 E314885 (3,4) REM10-xx15SW/ 24 / 48 15 670 89 / 89 350 (3,4) REM10-xx24SW/ 24 / 48 24 416 89 / 88.5 125 (3,4) REM10-xx05DW/ 24 / 48 5 1000 85 / 85 1440 (3,4) REM10-xx12DW/ 24 / 48 12 416 89 / 88 250 2MOPP (3,4) REM10-xx15DW/ 24 / 48 15 333 88 / 88 180 250VAC Model Numbering IEC/EN60601-1 certified CSA/CAN C22.2 60601-01 certified REM10- / ANSI/AAMI ES60601-1 certified (4) Output Power CTRL Option EN55011 certified (1) (3) Input Voltage Pinning (2) Output Voltage Input Type Single or Dual Notes: Note1: for 4:1 Input Voltage Type add W, see Note 2. 2:1 nom. Vin 4:1 W nom. Vin xx= 4.5-9 Vin = 05 xx= 9-36Vin = 24 xx= 9-18Vin = 12 xx= 18-75Vin = 48 xx= 18-36Vin = 24 xx= 36-75Vin = 48 Note2: Blank for Standard 2:1 Input Voltage Range W suffix for 4:1 Input Voltage Range Note3: A suffix for A pinning C suffix for C pinning, for more details refer to Package Style and Pinning Note4: CTRL suffix for control pin option, for A pinning only, for C pinning not available Examples: REM10-0512D/A = 2:1 Input, 4.5-9Vin, 12Vout, pinout A, without control pin REM10-1215S/C = 2:1 Input, 9-18Vin, 15Vout, pinout C, without control pin REM10-4815SW/A/CTRL = 4:1 Input, 36-75Vin, 15Vout, pinout A with control pin REM10-243.3SW/C = 4:1 Input, 9-36Vin, 3.3Vout, pinout C, without control pin www.recom-power.com REV.: 11/2019 MED-1REM10 DC/DC Converter Series Specifications (measured Ta= 25C, nominal input voltage, full load and after warm-up) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 5Vin nom. 16VDC 12Vin nom. 25VDC 2:1 input 24Vin nom. 50VDC Absolute Maximum Input Voltage 48Vin nom. 100VDC ( 3sec max.) 24Vin nom. 50VDC 4:1 input 48Vin nom. 100VDC 5Vin nom. 4VDC 4.5VDC 12Vin nom. 8VDC 9VDC 2:1 input 24Vin nom. 16VDC 18VDC Under Voltage Lockout 48Vin nom. 33VDC 36VDC 24Vin nom. 8VDC 9VDC 4:1 input 48Vin nom. 16VDC 18VDC Start-up Time constant resistive load, Power up or Remote ON/OFF 30ms DC-DC ON Open or 0-1.2VDC Remote ON/OFF (referenced to -Vin Pin) DC-DC OFF 2.2-12VDC Current of CTRL Pin -0.5mA 1mA Remote OFF Input Current 2.5mA Internal Operating Frequency 270kHz 300kHz 330kHz 10F/25V X7R MLCC for 3.3, 5Vout 30mVp-p Output Ripple and Noise 10F/25V X7R MLCC for 12, 15Vout 40mVp-p (20MHz BW limited) 4.7F/50V X7R MLCC for 24Vout 50mVp-p Efficiency vs. Load REM10-1212D 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Load % REGULATIONS Parameter Condition Type Value Output Accuracy 1.0% Line Regulation Single 0.2% low line to high line Dual 0.5% Single 0.2% Load Regulation no load to full load Dual 1.0% Cross Regulation asymmetrical load 25% / Full Load only Dual Output 5.0% Transient Response 25% load step change 250s www.recom-power.com REV.: 11/2019 MED-2 Efficiency %