Industry standard pinout Features 1kVDC/1s or 2kVDC/1s basic isolation DC/DC Converter UL94V-0 package material Optional continuous short circuit protection Unregulated Fully encapsulated Converters Efficiency up to 87% ROL Description 0.5 Watt The ROL DC/DC converters are typically used in general purpose low power isolation and voltage SIP4 matching applications, and feature a full industrial operating temperature range of -40C to +85C without derating. Single Output Selection Guide Part nom. Input Output Output Efficiency max. Capacitive (1) (2) Number Voltage Voltage Current typ. Load VDC VDC mA % F (3,4) ROL-xx05S 5, 12 5 100 78-82 470 (3,4) ROL-xx12S 5, 12 12 42 80-86 150 (3,4) ROL-xx15S 5, 12 15 33 80-87 150 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1 s without damage to the converter Model Numbering E358085 ROL- S/ (3) Protection Input Voltage UL60950-1 certified (4) Isolation Option Output Voltage CAN/CSA-C22.2 No. 60950-1-03 certified IEC60950-1 certified Single EN60950-1 certified Notes: Note3: standard part is without continuous short circuit protection add suffix /P for continuous short circuit protection Note4: add suffix /H for 2kVDC isolation or add suffix /HP for continuous short circuit protection and 2kVDC isolation Ordering Examples: ROL-1205S/P: 12V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection ROL-0505S/HP: 5V Input Voltage, 5V Output Voltage, Single Output with 2kVDC Isolation and continuous short circuit protection www.recom-power.com REV.: 1/2018 ECO-1ROL DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 10% (5) Minimum Load 0% Internal Operating Frequency 20kHz 54kHz Output Ripple and Noise 20MHz BW 100mVp-p Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Efficiency vs. Load ROL-0505S ROL-0515S 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % REGULATIONS Parameter Condition Value Output Accuracy 5.0% max. Line Regulation low line to high line 1.2% of 1.0% Vin typ. Load Regulation 10% to 100% load 4.0% typ. / 10.0% max. Deviation vs. Load ROL-0505S ROL-0515S 25 25 20 20 15 15 10 10 5 5 0 0 -5 -5 -10 -10 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % www.recom-power.com REV.: 1/2018 ECO-2 Deviation % Efficiency % Deviation % Efficiency %