C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r 12:1 ultra wide input voltage range Features 3kVAC/1 minute reinforced insulation High efficiency over entire input voltage range DC/DC Converter -40C to +68C temperature range without Regulated cooling or derating Output voltage sense and trim Converter RP60Q-RUW CE marked Description 60 Watt 3 The quarter brick RP60Q series DC/DC converter is designed for railway rolling stock and high voltage Quarter battery applications. It has a 12:1 input voltage range to cover all input voltages from nominal 24VDC up to 110VDC in a single product (including EN50155 transients) and offers isolated and Brick regulated 5V, 12V, 15V, 24V or 48VDC outputs with sense and trim pins. The converter has a consistently high efficiency over the entire input voltage range and has an operating temperature range from -40C to +68C without forced air cooling or derating. The case is fitted with threaded Single Output inserts for secure mounting in high shock and vibration environments. The converter is CE marked and comes with a three year warranty. Selection Guide Part Number Nom. Input Output Output Efficiency Max. Capacitive (1) (2) Voltage Range Voltage Current typ. Load VDC VDC A % F (3,4) RP60Q-11005SRUW/N 16-160 5 12 90 24000 22++ RoHSRoHS REACHREACH (3,4) compliantcompliant compliantcompliant RP60Q-11012SRUW/N 16-160 12 5 89 4200 10 from 1010 from 10 (3,4) RP60Q-11015SRUW/N 16-160 15 4 90 2700 (3,4) RP60Q-11024SRUW/N 16-160 24 2.5 90 1100 (3,4) RP60Q-11048SRUW/N 16-160 48 1.25 89 260 Notes: E196683 Note1: Efficiency is tested at 48Vin and full load at +25C ambient IEC/EN62368-1 certified Note2: Max. Cap Load is tested at nominal input and full resistive load UL62368-1 certified CAN/CSA-C22.2 No. 62368-1 certified EN50155 certified Model Numbering EN55032 compliant EN55024 compliant CE marked RP60Q- SRUW/N- (4) Output Power Heat-sink Option (3) Quarter Brick Size CTRL Logic nom. Input Voltage Railway Ultra Wide Input nom. Output Voltage Single REF DESIGN available Notes: Note3: standard part is with suffix /N for negative logic (0=ON, 1=OFF) or add suffix /P for positive logic (1=ON, 0=OFF) (5) for more details refer to ON/OFF CTRL RP60Q-RUW DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi-Type Input Voltage Range 16VDC 110VDC 160VDC Input Surge Voltage < 1s nom. Vin = 110VDC 185VDC DC-DC ON 14VDC Under Voltage Lockout (ULVO) nom. Vin = 110VDC DC-DC OFF 10VDC 11VDC 12VDC Vin = 16VDC 4.2A 5.2A Input Current Range Vin = 110VDC 0.6A Vin = 160VDC 0.45A Quiescent Current nom. Vin = 110VDC 10mA Output Voltage Trimming refer to OUTPUT VOLTAGE TRIMMING -20% +10% Minimum Load 0% Start-up Time constant resistive load 75ms 100ms Rise Time 40ms DC-DC ON Open or 3VDC < V < 12VDC CTRL Positive Logic (5) DC-DC OFF Short or 0VDC < V < 1.2VDC ON/OFF CTRL CTRL refer to ON/OFF CTRL DC-DC ON Short or 0VDC < V < 1.2VDC CTRL Negative Logic DC-DC OFF Open or 3VDC < V < 12VDC CTRL Input Current of CTRL pin drive current I -0.5mA 1mA CTRL Standby Current DC-DC OFF I 3mA In Internal Operating Frequency 180kHz 5Vout 75mVp-p 12, 15Vout 100mVp-p (6) Output Ripple and Noise measured at 20MHz BW 24Vout 200mVp-p 48Vout 300mVp-p (7) Remote Sense refer to REMOTE SENSE 10% Notes: Note5: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin Note6: Measurements are made for 5Vout with a 1F/25V X7R MLCC and a 22F/25V E-Cap for 15Vout with a 22F/25V X7R MLCC, for 24Vout with a 4.7F/50V X7R MLCC and for 48Vout with a 2.2F/100V X7R MLCC Note7: If not used connect Remote Sense pins to corresponding output pins RP60Q-11005SRW Efficiency vs. Output Load Efficiency vs. Input Voltage 100 100 90 90 80 80 70 70 60 60 50 50 40 40 24Vin 30 30 36Vin 100% load 20 20 48Vin 50% load 72Vin 10 10 25% load 110Vin 0 0 0 10 20 30 40 50 60 70 80 90 100 16 30 55 70 85 100 115 130 145 160 Output Load % Input Voltage VDC continued on next page www.recom-power.com REV.: 2/2020 PB-2 Efficiency % Efficiency %