2:1 and 4:1 Wide Input Voltage Ranges
ECONOLINE
Features
1kVDC, 2kVDC & 3kVDC Isolation
DC/DC-Converter
UL94V-0 Package Material
Regulated
with 3 year Warranty
Continuous Short Circuit Protection
Low Noise
Converters
No External Capacitor needed
Efficiency to 83 %
High power-density, an industrial temperature range of -40C to +85C and extra features
Description
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
2 Watt
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by choosing option/H2" or/H3" in which case it is also ideal for medical applications which
SIP8 Isolated
additionally require EN-60601-1 certification.
Selection Guide 5V, 12V, 24V and 48V Input Types
Single & Dual
Part Number Input Rated Output Output Current Efficiency Max
Voltage Range Voltage at Full Load typ. Capacitive
Output
SIP8 (VDC) (VDC) (mA) (%) Load
RS-xx3.3S (H2/H3) 4.5-9, 9-18 3.3 500 68-69 4700F
18-36, 36-72 70-73
RS-xx05S (H2/H3) 4.5-9, 9-18 5 400 73-75 1000F
18-36, 36-72 78
RS-xx09S (H2/H3) 4.5-9, 9-18 9 222 74-78 1000F
18-36, 36-72 81
RS-xx12S (H2/H3) 4.5-9, 9-18 12 166 75-80 1000F
18-36, 36-72 83
RoHS
RS-xx15S (H2/H3) 4.5-9, 9-18 15 134 75-80 1000F
2011/65/EU
6/6
E-224736
18-36, 36-72 83
RS-xx3.3D (H2/H3) 4.5-9, 9-18 3.3 250 68-69 2200F
UL-60950-1 Certified
18-36, 36-72 70-73
EN-60950-1 Certified
RS-xx05D (H2/H3) 4.5-9, 9-18 5 200 73-75 680F
EN-60601-1 Certified*
18-36, 36-72 78
(*/H suffix)
RS-xx09D (H2/H3) 4.5-9, 9-18 9 111 74-78 680F
18-36, 36-72 81
RS-xx12D (H2/H3) 4.5-9, 9-18 12 83 75-80 680F
RS
18-36, 36-72 83
RS-xx15D (H2/H3) 4.5-9, 9-18 15 67 75-80 680F
18-36, 36-72 83
RS-xx3.3SZ (H2/H3) 9-36 3.3 500 75 4700F
Derating-Graph
18-72 75
RS-xx05SZ (H2/H3) 9-36 5 400 80 1000F (Ambient Temperature)
18-72 80
RS-S(Z)_D(Z)
RS-xx09SZ (H2/H3) 9-36 9 222 80 1000F
18-72 80
RS-xx12SZ (H2/H3) 9-36 12 166 83 1000F
G
G
18-72 83
RS-xx15SZ (H2/H3) 9-36 15 134 84 1000F
!
18-72 84
RS-xx3.3DZ (H2/H3) 9-36 3.3 250 73 2200F
18-72 73
RS-xx05DZ (H2/H3) 9-36 5 200 77 680F
.
18-72 77
RS-xx09DZ (H2/H3) 9-36 9 111 80 680F
18-72 80
2:1 Input 4:1 Input
RS-xx12DZ (H2/H3) 9-36 12 83 81 680F
(RS-S/D) (RS-SZ/DZ)
18-72 81
xx = 4.5-9Vin = 05 xx = 9-36Vin = 24
RS-xx15DZ (H2/H3) 9-36 15 67 83 680F
xx = 9-18Vin = 12 xx = 18-72Vin = 48
18-72 83
xx = 18-36Vin = 24
xx = 36-72Vin = 48
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-126 REV: 2/2017 www.recom-power.com
RS
Detailed Information see
Application Notes chapterMTB
RS-S_D(Z)
ECONOLINE
DC/DC-Converter
Series
Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up time unless otherwise specified)
A
Input Voltage Range 2:1 and 4:1
Output Accuracy 2% typ.
Line Voltage Regulation 0.5% max.
Load Voltage Regulation 20%-100% Load 0.5% max.
(2)
Minimum Load 10%
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Switching Frequency Full Load 100kHz min. / 300kHz max.
Efficiency at Full Load See Selection Guide
Quiescent Current RS-05xxS_D 40mA typ.
Nominal input Voltage RS-12xxS_D 32mA typ.
(Standard, /H2 and /H3) RS-24xxS_D, SZ_DZ 25mA typ.
RS-48xxS_D, SZ_DZ 15mA typ.
Isolation Voltage Standard (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
/H2 Version (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
/H3 Version (tested for 1 second) 3000VDC
(rated for 1 minute**) 1500VAC / 60Hz
Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max.
/H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max.
Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max.
/H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max.
Standard 4:1 Single/Dual 200pF max.
/H2 and /H3 4:1 Single/Dual 30pF max
Isolation Resistance 1G min.
Short Circuit Protection Continuous
Operating Temperature Range 2:1 40C to +85C
(No Derating) 4:1 40C to +75C
Storage Temperature Range 55C to +125C
Relative Humidity 95% RH
Package Weight 4.7g
Packing Quantity 22 pcs per Tube
3
MTBF (+25C) using MIL-HDBK 217F 1398 x 10 hours
}
3
(+85C) using MIL-HDBK 217F 210 x 10 hours
Certifications
EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety Report: E224736-A35 UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com REV: 2/2017 E-127