2:1 and 4:1 Wide Input Voltage Ranges ECONOLINE Features 1kVDC, 2kVDC & 3kVDC Isolation DC/DC-Converter UL94V-0 Package Material Regulated with 3 year Warranty Continuous Short Circuit Protection Low Noise Converters No External Capacitor needed Efficiency to 83 % High power-density, an industrial temperature range of -40C to +85C and extra features Description like Remote-On-Off- control are just some of the characteristics of this converter, ideal for 2 Watt highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV by choosing option/H2 or/H3 in which case it is also ideal for medical applications which SIP8 Isolated additionally require EN-60601-1 certification. Selection Guide 5V, 12V, 24V and 48V Input Types Single & Dual Part Number Input Rated Output Output Current Efficiency Max Voltage Range Voltage at Full Load typ. Capacitive Output SIP8 (VDC) (VDC) (mA) (%) Load RS-xx3.3S (H2/H3) 4.5-9, 9-18 3.3 500 68-69 4700F 18-36, 36-72 70-73 RS-xx05S (H2/H3) 4.5-9, 9-18 5 400 73-75 1000F 18-36, 36-72 78 RS-xx09S (H2/H3) 4.5-9, 9-18 9 222 74-78 1000F 18-36, 36-72 81 RS-xx12S (H2/H3) 4.5-9, 9-18 12 166 75-80 1000F 18-36, 36-72 83 RoHS RS-xx15S (H2/H3) 4.5-9, 9-18 15 134 75-80 1000F 2011/65/EU 6/6 E-224736 18-36, 36-72 83 RS-xx3.3D (H2/H3) 4.5-9, 9-18 3.3 250 68-69 2200F UL-60950-1 Certified 18-36, 36-72 70-73 EN-60950-1 Certified RS-xx05D (H2/H3) 4.5-9, 9-18 5 200 73-75 680F EN-60601-1 Certified* 18-36, 36-72 78 (*/H suffix) RS-xx09D (H2/H3) 4.5-9, 9-18 9 111 74-78 680F 18-36, 36-72 81 RS-xx12D (H2/H3) 4.5-9, 9-18 12 83 75-80 680F RS 18-36, 36-72 83 RS-xx15D (H2/H3) 4.5-9, 9-18 15 67 75-80 680F 18-36, 36-72 83 RS-xx3.3SZ (H2/H3) 9-36 3.3 500 75 4700F Derating-Graph 18-72 75 RS-xx05SZ (H2/H3) 9-36 5 400 80 1000F (Ambient Temperature) 18-72 80 RS-S(Z) D(Z) RS-xx09SZ (H2/H3) 9-36 9 222 80 1000F 18-72 80 RS-xx12SZ (H2/H3) 9-36 12 166 83 1000F G G 18-72 83 RS-xx15SZ (H2/H3) 9-36 15 134 84 1000F 18-72 84 RS-xx3.3DZ (H2/H3) 9-36 3.3 250 73 2200F 18-72 73 RS-xx05DZ (H2/H3) 9-36 5 200 77 680F . 18-72 77 RS-xx09DZ (H2/H3) 9-36 9 111 80 680F 18-72 80 2:1 Input 4:1 Input RS-xx12DZ (H2/H3) 9-36 12 83 81 680F (RS-S/D) (RS-SZ/DZ) 18-72 81 xx = 4.5-9Vin = 05 xx = 9-36Vin = 24 RS-xx15DZ (H2/H3) 9-36 15 67 83 680F xx = 9-18Vin = 12 xx = 18-72Vin = 48 18-72 83 xx = 18-36Vin = 24 xx = 36-72Vin = 48 No suffix is standard isolation (1kVDC) e.g, RS-0505S *add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3 E-126 REV: 2/2017 www.recom-power.com RS Detailed Information see Application Notes chapterMTB RS-S D(Z) ECONOLINE DC/DC-Converter Series Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up time unless otherwise specified) A Input Voltage Range 2:1 and 4:1 Output Accuracy 2% typ. Line Voltage Regulation 0.5% max. Load Voltage Regulation 20%-100% Load 0.5% max. (2) Minimum Load 10% Output Ripple and Noise (20MHz limited) 50mVp-p max. Switching Frequency Full Load 100kHz min. / 300kHz max. Efficiency at Full Load See Selection Guide Quiescent Current RS-05xxS D 40mA typ. Nominal input Voltage RS-12xxS D 32mA typ. (Standard, /H2 and /H3) RS-24xxS D, SZ DZ 25mA typ. RS-48xxS D, SZ DZ 15mA typ. Isolation Voltage Standard (tested for 1 second) 1000VDC (rated for 1 minute**) 500VAC / 60Hz /H2 Version (tested for 1 second) 2000VDC (rated for 1 minute**) 1000VAC / 60Hz /H3 Version (tested for 1 second) 3000VDC (rated for 1 minute**) 1500VAC / 60Hz Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max. /H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max. Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max. /H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max. Standard 4:1 Single/Dual 200pF max. /H2 and /H3 4:1 Single/Dual 30pF max Isolation Resistance 1G min. Short Circuit Protection Continuous Operating Temperature Range 2:1 40C to +85C (No Derating) 4:1 40C to +75C Storage Temperature Range 55C to +125C Relative Humidity 95% RH Package Weight 4.7g Packing Quantity 22 pcs per Tube 3 MTBF (+25C) using MIL-HDBK 217F 1398 x 10 hours 3 (+85C) using MIL-HDBK 217F 210 x 10 hours Certifications EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013 EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment UL General Safety Report: E224736-A35 UL60950-1, 2nd Edition 2014 CSA C22.2 60950-1-07, 2nd Edition 2014 **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. Notes Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter Note 2: The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions will not damage these devices however, they may not meet all listed specifications. www.recom-power.com REV: 2/2017 E-127