2:1 and 4:1 Wide Input Voltage Ranges ECONOLINE Features 1kVDC, 2kVD or 3kVDC Isolation DC/DC-Converter UL94V-0 Package Material Regulated Certified for Medical Applications with 3 year Warranty Continuous Short Circuit Protection Converters Low Noise No External Capacitor needed Efficiency to 83 % High-power-density, an industrial temperature range of -40C to +85C and extra features like Description On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option/H2 or/H3 in which case it is also ideal for medical applications which additionally require EN-60601- 1 Watt 1 certification. The standard version offers 2:1 input voltage range, while the Z version features 4:1 input voltage range, which includes an input voltage range covering both 5V and 12V supplies. SIP8 Isolated Selection Guide Part Number Input Rated Output Output Current Efficiency Max Single & Dual Voltage Range Voltage typ. Capacitive (1) SIP8 (VDC) (VDC) (mA) (%) Load Output RSO-xx3.3S* 4.5-9**, 9-18 3.3 300 68-72 3300F 18-36, 36-72 70 RSO-xx05S* 4.5-9**, 9-18 5 200 73-75 1200F 18-36, 36-72 75-78 RSO-xx09S* 4.5-9**, 9-18 9 111 74-78 680F 18-36, 36-72 78-81 RSO-xx12S* 4.5-9**, 9-18 12 83 75-80 680F 18-36, 36-72 80-83 RSO-xx15S* 4.5-9**, 9-18 15 67 75-80 680F RoHS 18-36, 36-72 80-83 2011/65/EU 6/6 RSO-xx3.3D* 4.5-9**, 9-18 3.3 150 68-72 1500F 18-36, 36-72 70 EN-60950-1 Certified RSO-xx05D* 4.5-9**, 9-18 5 100 73-75 470F EN-60601-1 Certified* 18-36, 36-72 75-76 (*/H suffix) RSO-xx09D* 4.5-9**, 9-18 9 56 74-78 470F 18-36, 36-72 78 RSO-xx12D* 4.5-9**, 9-18 12 42 75-79 330F RSO 18-36, 36-72 79-80 RSO-xx15D* 4.5-9**, 9-18 15 34 75-79 330F 18-36, 36-72 79-80 RSO-xx3.3SZ* 9-36 3.3 300 68-70 3300F Derating-Graph 18-72 70 RSO-xx05SZ* 4.5-18**, 9-36 5 200 73-78 1200F (Ambient Temperature) 18-72 75 RSO-xx09SZ* 4.5-18**, 9-36 9 111 75-81 680F 18-72 78 RSO-xx12SZ* 4.5-18**, 9-36 12 83 77-83 680F I I 18-72 80 RSO-xx15SZ* 4.5-18**, 9-36 15 67 78-83 680F 18-72 80 RSO-xx3.3DZ* 9-36 3.3 150 70-74 1500F 18-72 70 RSO-xx05DZ* 4.5-18**, 9-36 5 100 73-77 470F . 18-72 75 RSO-xx09DZ* 4.5-18**, 9-36 9 56 74-78 470F 18-72 78 RSO-xx12DZ* 4.5-18**, 9-36 12 42 75-80 330F 2:1 Input 4:1 Input 18-72 80 (RS0-S/D) (RSO-SZ/DZ) RSO-xx15DZ* 4.5-18**, 9-36 15 34 75-80 330F xx = 4.5-9Vin = 05 xx = 4.5-18Vin = 12 18-72 80 xx = 9-18Vin = 12 xx = 9-36Vin = 24 No suffix is standard isolation (1kVDC) e.g, RSO-0505S xx = 18-36Vin = 24 xx = 18-72Vin = 48 *add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3 xx = 36-72Vin = 48 ** derate to 75% if Vin<5V, 12V 4:1 input also requires an external 10F input capacitor. Refer to Application Notes www.recom-power.com REV: 0/2015 E-123 RSO-S D(Z) ECONOLINE DC/DC-Converter Series Specifications (Core Operating Area) measured at T = 25C, nominal input voltage, full load and after warm-up time unless otherwise specified A Input Voltage Range 2:1 and 4:1 Output Voltage Accuracy 2% typ. Line Voltage Regulation 2:1 0.2% max. 4:1 0.5% max. Load Voltage Regulation 2:1 0.4% max. (10% to 100% full load) 4:1 0.5% typ. (2) Minimum Load 10% RSO-24xxS Output Ripple and Noise (20MHz limited) 50mVp-p max. Operating Frequency 2:1 200kHz min. / 500kHz max. 3 + +4 % & 4:1 100kHz min. / 800kHz max. Efficiency at Full Load See Selection Guide / Quiescent Current RSO-05xxS D, SZ DZ 40mA typ. Nominal input Voltage RSO-12xxS D, SZ DZ 32mA typ. (Standard, /H2 and /H3) RSO-24xxS D, SZ DZ 25mA typ. RSO-48xxS D, SZ DZ 15mA typ. CTRL Pin drive current /see Notes) 3mA typ, 6mA max. * + Quiescent Input Current when Converter is OFF 10mA max. Isolation Voltage Standard (tested for 1 second) 1000VDC (rated for 1 minute**) 500VAC / 60Hz /H2 Version (tested for 1 second) 2000VDC (rated for 1 minute**) 1000VAC / 60Hz /H3 Version (tested for 1 second) 3000VDC (rated for 1 minute**) 1500VAC / 60Hz RSO-1205SZ Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max. 3 + +4 % & Isolation Capacitance /H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max. Isolation Capacitance Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max. F Isolation Capacitance /H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max. Isolation Capacitance Standard 4:1 Single/Dual 200pF max. Isolation Capacitance /H2 and /H3 4:1 Single/Dual 30pF max. Isolation Resistance >1G min. Short Circuit Protection Continuous Operating Temperature Range (free air convection) -40C to +85C (see Graph) * + Storage Temperature Range -55C to +125C Relative Humidity 95% RH Package Weight 4.7g Packing Quantity 22 pcs per Tube 3 MTBF (+25C) using MIL-HDBK 217F 1685 x 10 hours Detailed Information see **Any data referred to in this datasheet are of indicative nature and Application Notes chapterMTB 3 based on our practical experience only. For further details, please (+85C) using MIL-HDBK 217F 254 x 10 hours refer to our Application Notes. Certifications EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + A11:2009+A1:2010+A12:2011 EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment Notes Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter Note 2: The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions will not damage these devices however, they may not meet all listed specifications. E-124 REV: 0/2015 www.recom-power.com RS0 3 + +4 3 + +4