1:1 Input Range ECONOLINE Features Efficiency up to 84% DC/DC-Converter 2kVDC and 3kVDC Isolation Option Unregulated Approved for Medical Applications Converters -40C to +90C Operating Temperature Range 2W SMD Package Selection Guide Part Isolation Input Output Output Capacitive Number Voltage Voltage Voltage Current Efficiency Load (1) SMD (kV) (VDC) (VDC) (mA) (max.) (max.) 2 Watt SMD RTM-0505S* 2 5 5 400 79% 2200F Single Output RTM-1205S* 2 12 5 400 83% 2200F RTM-2405S* 2 24 5 400 84% 2200F * add Suffix /H for 3kVDC/1sec. Isolation e.g. RTM-0505S/H * add Suffix -R for tape&reel packing e.g. RTM-1205S-R or RTM-2405S/H-R Specifications (measured at T = 25C, nominal input voltage and rated output current unless otherwise specified) A Input Voltage Range 10% max. Output Voltage Accuracy -1% typ., 5% max. Line Voltage Regulation (low line to high line at max. load) 1.2% typ. RoHS 2011/65/EU Load Voltage Regulation (10% to 100% full load) 10% typ., 15% max. 6/6 Output Ripple and Noise (20MHz BW limited) 50mVp-p typ., 100mVp-p max. Operating Frequency (Vin=nominal input) 20kHz min. / 40kHz typ. / 80kHz max. Efficiency at Full Load see Selection Guide Minimum Load = 0% Specifications valid for 10% minimum load only EN-60601-1 Certified Isolation Voltage (tested for 1 second) 2000 VDC EN-60950-1 Certified (rated for 1 minute**) 1600VDC Isolation Voltage H-Suffix (tested for 1 second) 3000 VDC H-Suffix (rated for 1 minute**) 2400VDC RTM Isolation Capacitance 30pF typ., 50pF max. Isolation Resistance (Viso=500V) 15G min. Short-Circuit Protection 1 second Derating-Graph Operating Temperature Range with Derating -40C to +90C Storage Temperature -55C to +125C (Ambient Temperature) Reflow Temperature RoHS compliant 245C (30 sec.), Peak 255C (5sec.) max. Vapor Phase Process (for more details see Application Notes) 230C (90 sec.) max. Relative Humidity 95% RH Package Weight 1.4g Packing Quantity All Types 27 pcs per Tube All Types 500 pcs per Reel MTBF (+25C) using MIL-HDBK 217F 3907 x 10 hours Detailed Information see Application Notes chapterMTB MTBF (+85C) using MIL-HDBK 217F 313 x 10 hours Certifications / EN Medical Safety Report: MDD1112018 + RM1112018 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment EN General Safety Report: SPCLVD1112018 EN60950-1, 2nd Edition **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. Note: Note1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter Refer to Application Notes www.recom-power.com REV: 0/2015 E-83 4 + * & & RTM Series ECONOLINE DC/DC-Converter Typical Characteristics RTM-xx05S % & 3 + +4 % & * + * + Tolerance Envelope 1 1 1 , ) ( 2 2 & Pin Connections Pin Function + 3 1 +Vin 3 2 -Vin 12 -Vout 13 +Vout Recommended Footprint Details 14~17 NC 27,28 NC NC = No Connection ( ) Unit: mm = Tolerance: 0.25 mm > 4 EMC Filtering - Suggestion for EN55022 Class B . 8% 9, 8 7 Input Inductance/ Voltage Capacitance (C1) 5V 4.7F 12V 2.2F 24V 47F <) <) The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOMs explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-84 REV: 0/2015 www.recom-power.com Package Style and Pinning 3 + +4 , * ) * RTM