C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r IEC60601-1 for medical applications Features UL/CSA/IEC/EN safety certified and CB report 6.4kVDC/1s or 8kVDC/1s reinforced isolation DC/DC Converter Optional continuous short circuit protection Unregulated Efficiency up to 88% Space saving package Converters RV/R Very low isolation capacitance Description 2 Watt Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal 3 DIP24 for highly sophisticated industrial, test and measurement and medical designs where board space is at a premium. miniature Single and Dual Selection Guide Part nom. Input Output Output Efficiency max. Capacitive Output (1) (2) Number Voltage Voltage Current typ. Load VDC VDC mA % F (3,4) RV-xx3.3S 3.3, 5, 12, 15, 24 3.3 600 70-78 3300 (3,4) RV-xx05S 3.3, 5, 12, 15, 24 5 400 76-80 1200 (3,4) RV-xx09S 3.3, 5, 12, 15, 24 9 222 78-85 1200 (3,4) RV-xx12S 3.3, 5, 12, 15, 24 12 167 78-85 680 (3,4) RV-xx15S 3.3, 5, 12, 15, 24 15 132 78-88 680 (3,4) RV-xx3.3D 3.3, 5, 12, 15, 24 3.3 300 70-78 1500 (3,4) RV-xx05D 3.3, 5, 12, 15, 24 5 200 75-82 470 (3,4) RV-xx09D 3.3, 5, 12, 15, 24 9 111 76-84 470 (3,4) RV-xx12D 3.3, 5, 12, 15, 24 12 85 78-86 220 22++ RoHSRoHS REACHREACH compliantcompliant compliantcompliant (3,4) 10 from 1010 from 10 RV-xx15D 3.3, 5, 12, 15, 24 15 66 78-86 220 E314885 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max Cap Load is tested at nominal input and full resistive load UL60950-1 certified Model Numbering CAN/CSA-C22.2 No. 60950-1 certified IEC/EN60950-1 certified ANSI/AAMI ES60601-1 certified RV- S R (3) CAN/CSA-C22.2 No. 60601-1 certified Input Voltage Reinforced Isolation IEC/EN60601-1 certified (4) Output Voltage Protection IEC/EN61010 certified CB report Single or Dual Notes: Note3: add suffix /R6.4 for 6.4kVDC/1second isolation or /R8 for 8kVDC/1second isolation Note4: standard part is without continuous short circuit protection add suffix /P for continuous short circuit protection Ordering Examples RV-1212D/R6.4 = 12V Input, 12V Output, Dual, 6.4kVDC/1s isolation RV-053.3S/P/R8 = 5V Input, 3.3V Output, Single, short circuit protection,8kVDC/1s isolation www.recom-power.com REV.: 6/2020 ECO-1 O O P P E a C C R R O O Y M M n D D O O U U t C C C C E E y T T R R S STypical Load Line RV/R DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 10% Minimum Load 0% Internal Operating Frequency 20kHz 50kHz 85kHz Output Ripple and Noise 20MHz BW 200mVp-p Efficiency vs. Load RV-xx05S/R6.4 and RV-xx05S/R8 RV-xx05D/R6.4 and RV-xx05D/R8 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 0505 0505 20 20 1205 1205 10 10 2405 2405 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % REGULATIONS Parameter Condition Value Output Accuracy 5.0% max. Line Regulation low line to high line 1.2% of 1.0% Vin typ. 3.3Vout 20.0% max. (5) Load Regulation 10% to 100% load 5Vout 15.0% max. 9, 12, 15Vout 10.0% max. Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Tolerance Envelope 9, 12, 15, 24Vout +10% +6% +5% Vnom -2.5% -5% 10 50 100 Output Load % continued on next page www.recom-power.com REV.: 6/2020 ECO-2 Efficiency % Output Voltage % Efficiency %