2:1 Wide Range Voltage Input ECONOLINE Features 1kVDC, 2kVDC and 3kVDC Isolation DC/DC-Converter Approved for Medical Applications Continuous Short Circuit Protection Regulated with 3 year Warranty Low Ripple and Noise Converters DIP16, mini DIP16 and SMD Cases Styles Efficiency to 83 % High power-density, 2:1 input voltage range and a wide temperature range of -40C to +85C Description are just some of the characteristics of this versatile DIP16 converter, ideal for highly 2 Watt sophisticated industrial and medical designs where a regulated converter is required but space is at a premium. Three different case styles and isolation options are available. DIP16, Mini Selection Guide DIP16 & SMD Part Number Input Rated Output Output Current Efficiency Max Voltage Range Voltage Full Load typ./nom Vin Capacitive Single & Dual (1) DIP16 (Mini & SMD) (VDC) (VDC) (mA) (%) Load RW2-053.3S (H2/H3) 4.5 - 9 3.3 500 68 4700F Output RW2-0505S (H2/H3) 4.5 - 9 5 400 73 1000F RW2-0512S (H2/H3) 4.5 - 9 12 166 75 1000F RW2-0515S (H2/H3) 4.5 - 9 15 134 75 1000F RW2-123.3S (H2/H3) 9 - 18 3.3 500 69 4700F RW2-1205S (H2/H3) 9 - 18 5 400 75 1000F RW2-1212S (H2/H3) 9 - 18 12 166 80 1000F RW2-1215S (H2/H3) 9 - 18 15 134 80 1000F RoHS RW2-243.3S (H2/H3) 18 - 36 3.3 500 70 4700F 2011/65/EU 6/6 RW2-2405S (H2/H3) 18 - 36 5 400 78 1000F RW2-2412S (H2/H3) 18 - 36 12 166 83 1000F EN-60950-1 Certified RW2-2415S (H2/H3) 18 - 36 15 134 83 1000F (All Suffixes) RW2-483.3S (H2/H3) 36 - 72 3.3 500 73 4700F EN-60601-1 Certified* RW2-4805S (H2/H3) 36 - 72 5 400 76 1000F (*/H suffix) RW2-4812S (H2/H3) 36 - 72 12 166 81 1000F RW2-4815S (H2/H3) 36 - 72 15 134 81 1000F RW2-0505D (H2/H3) 4.5 - 9 5 200 73 680F RW2 RW2-0509D (H2/H3) 4.5 - 9 9 111 74 680F RW2-0512D (H2/H3) 4.5 - 9 12 83 75 680F RW2-0515D (H2/H3) 4.5 - 9 15 67 75 680F RW2-1205D (H2/H3) 9 - 18 5 200 75 680F RW2-1209D (H2/H3) 9 - 18 9 111 78 680F Derating-Graph RW2-1212D (H2/H3) 9 - 18 12 83 80 680F RW2-1215D (H2/H3) 9 - 18 15 67 80 680F (Ambient Temperature) RW2-2405D (H2/H3) 18 - 36 5 200 78 680F RW2-2409D (H2/H3) 18 - 36 9 111 81 680F RW2-2412D (H2/H3) 18 - 36 12 83 83 680F RW2-2415D (H2/H3) 18 - 36 15 67 83 680F RW2-4805D (H2/H3) 36 - 72 5 200 78 680F RW2-4809D (H2/H3) 36 - 72 9 111 81 680F RW2-4812D (H2/H3) 36 - 72 12 83 83 680F RW2-4815D (H2/H3) 36 - 72 15 67 83 680F Standard Isolation is 1kVDC. Add suffix /H2 for 2kVDC Isolation, /H3 for 3kVDC Isolation. Add no suffix for standard case style, /SMD for SMD package or /B for smaller case size e.g. RW2-0505S/H3, RW2-0505D/H2/SMD or RW2-0505S/B Notes / Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1second without damage to the converter Note 2: The RW2 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions will not damage these devices however, they may not meet all listed specifications. Refer to Application Notes www.recom-power.com REV: 0/2015 E-129 RW2 ECONOLINE DC/DC-Converter Series Electrical Specifications (measured at T = 25C, at nominal input voltage and rated output current unless otherwise specified) A Input Voltage Range 2:1 Output Accuracy 2% typ. Line Voltage Regulation 0.5% max. Load Voltage Regulation (20% to 100% full load) 0.5% typ. (2) Minimum Load 10% Output Ripple and Noise (20MHz limited) 50mVp-p max. Switching Frequency (at full Load) 100kHz min. / 700kHz max. Efficiency at Full Load 70% min. / 80% typ. Isolation Voltage (tested for 1 second) 1000VDC (rated for 1 minute*) 500VAC / 60Hz H2-Suffix (tested for 1 second) 2000VDC (rated for 1 minute*) 1000VAC / 60Hz H3-Suffix (tested for 1 second) 3000VDC (rated for 1 minute*) 1500VAC / 60Hz Isolation Capacitance 30pF max. Isolation Resistance 1G min. Short Circuit Protection Continuous Operating Temperature Range 40C to +85C (see Graph) Storage Temperature Range 55C to +125C Case Temperature 100C max. Relative Humidity 95% RH Package Weight 6.4g Packing Quantity Case Style A, SMD 20 pcs per tube Case Style B 22 pcs per Tube MTBF (+25C) using MIL-HDBK 217F 4366 x10 hours For Detailed Information see Application Notes chapterMTB (+85C) using MIL-HDBK 217F 658 x10 hours **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. Package Style and Pinning (mm) ( ( ( ( ( ( ( /(. ( ( ( ( ( (/ 5 ( ( ( Case Style B Case Style A ( ( ( ( ( - , ( ( - , ( ( / ( / . 5 ( , . 5 ( , Recommended Footprint Details 16 Pin DIP Package Recommended Footprint Details 16 Pin Mini-DIP Package Pin Connections (All Case Styles) ( ( Pin Single Dual ( /(. 1 Vin Vin 7 NC NC ( ( 8 NC Com SMD Case Style 9 +Vout +Vout ( ( ( ( 5 ( 10 Vout Vout ( XX.X 0.5 mm 16 +Vin +Vin . XX.XX 0.35 mm , - , /( . ( Certifications .( / EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + A12:2011 . 5 ( .(. EN Medical Safety Report: MDD1205098-3 + RM1205098-3 16 Pin SMD Package Recommended Pad Details IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOMs explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-130 REV: 0/2015 www.recom-power.com RW2