On/Off Pin Features ECONOLINE 1kVDC Isolation DC/DC-Converter UL94V-0 Package Material Regulated with 3 year Warranty Optional Continuous Short Circuit Protected Converters Internal linear regulator Efficiency to 70 % The RY series DC/DC converter is a low cost general purpose isolated converter with a Description built-in linear regulator to give a regulated, load-independent output. It is available with single or dual outputs. A useful feature is the CTRL pin on the single output version which allows to controll the converter with an external enable signal. 1 Watt Selection Guide SIP7 Part Input Output Output Efficiency Max Number Voltage Voltage Current Capacitive (1) SIP 7 (VDC) (VDC) (mA) (%) Load Single & Dual RY-xx05S 5, 9, 12, 15, 24 5 200 58-60 1200F Output RY-xx09S 5, 9, 12, 15, 24 9 111 56-62 1200F RY-xx12S 5, 9, 12, 15, 24 12 84 60-66 680F RY-xx15S 5, 9, 12, 15, 24 15 66 60-66 680F RY-xx24S 5, 9, 12, 15, 24 24 42 60-68 220F RY-xx05D 5, 9, 12, 15, 24 5 100 50-58 470F RY-xx09D 5, 9, 12, 15, 24 9 55 52-60 470F RY-xx12D 5, 9, 12, 15, 24 12 42 58-68 330F RY-xx15D 5, 9, 12, 15, 24 15 33 62-68 330F RY-xx24D 5, 9, 12, 15, 24 24 21 64-70 100F RoHS 2011/65/EU xx = Input Voltage. Other input and output voltage combinations available on request. 6/6 * add Suffix P for Continuous Short Circuit Protection, e.g. RY-0505S/P, RY-0505D/P Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up) EN-60950-1 Certified A Input Voltage Range 5% Output Voltage Accuracy 5% Line Voltage Regulation 1% max. RY Load Voltage Regulation (10% to 100% full load) 1% max. (2) Minimum Load 10% Output Ripple and Noise (20MHz limited) 100mVp-p max. Operating Frequency 30kHz min. / 50kHz typ. / 88kHz max. Derating-Graph Efficiency at Full Load 54% min. / 60% typ. Isolation Voltage (tested for 1 second) 1000VDC (Ambient Temperature) (rated for 1 minute**) 500VAC / 60Hz Isolation Capacitance Single output types 30pF min. / 150pF max. Dual output types 40pF min. / 72pF max. Isolation Resistance 10 GW min. Short Circuit Protection 1 Second P-Suffix Continuous Operating Temperature Range (free air convection) -40C to +70C (see Graph) Storage Temperature Range -55C to +125C Relative Humidity 95% RH Package Weight RY Single & Dual output types 2.8g . Packing Quantity 25 pcs per Tube 3 MTBF (+25C) Detailed Information see using MIL-HDBK 217F 924 x 10 hours Application Notes chapterMTB 3 (+70C) using MIL-HDBK 217F 135 x 10 hours **Any data referred to in this datasheet are of indicative nature Certifications and based on our practical experience only. For further details, please refer to our Application Notes. EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12:2011 continued on next page www.recom-power.com REV: 3/2018 E-121 RY ECONOLINE Series DC/DC-Converter Specifications (measured at T = 25C, nominal input voltage, full load and after warm-up) A Notes Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter Note 2: The RY series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions will not damage these devices however, they may not meet all listed specifications. Typical Characteristics RY-xx05S RY-xx12S RY-xx15S 3 + +4 % & 3 + +4 % & 3 + +4 % & * + * + * + RY-xx05D RY-xx12D RY-xx15D 3 + +4 % & 3 + +4 % & 3 + +4 % & * + * + * + Package Style and Pinning (mm) SIP7 Package .( * * > ( > > ( 4 ( ( 4 ( ( Pin Connections Pin Single Dual Recommended Footprint Details 1 +Vin +Vin 0 ( 1 ( %2 2 Vin Vin /( 4 Vout Vout ( ( ( . 5 CTRL Com - , 6 +Vout +Vout XX.X 0.5 mm ( 5 ( XX.XX 0.25 mm , ( The product information and specifications may be subject to changes even without prior written notice. The product has been designed for various applications its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOMs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-122 REV: 3/2018 www.recom-power.com RY 3 + +4 3 + +4 3 + +4 3 + +4 3 + +4 3 + +4