Bulletin No. CUB5T-D Drawing No. LP0628 Released 07/12 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL CUB5T - MINIATURE ELECTRONIC PRESET TIMER AND CYCLE COUNTER LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING 0.46 (11.7 mm) HIGH DIGITS 7-DIGIT BI-DIRECTIONAL TIMING CAPABILITY 6-DIGIT CYCLE COUNTING CAPABILITY OPTIONAL RELAY OUTPUT MODULE OPTIONAL SERIAL COMMUNICATIONS MODULE (RS232 or RS485) SELECTABLE TIMER RANGES AND OPERATING MODES ELAPSED TIMER AND PRESET TIMER FUNCTIONALITY DISPLAY COLOR CHANGE CAPABILITY AT PRESET OUTPUT U R CC L US LISTEDUS LISTED IND. CONT. EQ. OPERATES FROM 9 TO 28 VDC POWER SOURCE 51EB NEMA 4X/IP65 SEALED FRONT BEZEL GENERAL DESCRIPTION The CUB5T provides the ultimate in timer flexibility, from its complete user The CUB5T can be powered from an optional Red Lion Micro-Line/Sensor programming to the optional relay output and serial communications capability. Power Supply (MLPS), which attaches directly to the back of a CUB5T. The The meter functions as an Elapsed Timer or Preset Timer. It also has a built-in MLPS is powered from an 85 to 250 VAC source and provides up to 400 mA to Cycle Counter. The display can be toggled either manually or automatically drive the meter and sensors. between the Timer and Cycle Counter values. With eight different input operating modes and 18 selectable timer ranges, the meter can be programmed SAFETY SUMMARY for a wide variety of timing applications. All safety related regulations, local codes and instructions that appear in this The CUB5T has an LCD display with 0.46 (11.7 mm) high digits. The LCD literature or on equipment must be observed to ensure personal safety and to is available in two versions, reflective (CUB5TR00) and backlight (CUB5TB00). prevent damage to either the instrument or equipment connected to it. If The backlight version is user selectable for red or green backlighting with equipment is used in a manner not specified by the manufacturer, the protection variable display intensity. provided by the equipment may be impaired. The Timer has two signal inputs and eight input operating modes. These Do not use this meter to directly command motors, valves, or other actuators modes provide level active or edge triggered start/stop operation. A Display not equipped with safeguards. To do so can be potentially harmful to persons or Hold mode will display the elapsed time for one cycle, while the next cycle equipment in the event of a fault to the meter. continues timing internally. The Timer Reset modes will automatically reset the timer value when a time start edge is applied to the input. This allows sequential timing cycles without having to manually reset the Timer. In addition to the Timer inputs, a programmable User Input is available to perform a variety of meter functions. All inputs are current sinking (active low) and accept a variety of logic and open-collector output signal sources. Relay and CAUTION: Risk of Danger. CAUTION: Risk of electric shock. Read complete instructions prior to switch contacts can also be used as signal sources, when the software input installation and operation of the unit. debounce filter is enabled. The capability of the CUB5T can be easily expanded with the addition of a field installable option module. When the CUB5RLY0 relay output module is added, the meter becomes a Preset Timer. The Setpoint Output can be assigned to the Timer or Cycle Counter values, and configured to suit a variety of control and alarm requirements. Serial communications capability for RS232 or RS485 is added with a serial option module (CUB5COM). DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15 (54.6) H x 3.00 (76.2) W13 (3.3) ON ECE +.024 1.30 1 2 34 -.000 1.54 (39.1) 1.29 (32.8) +6 (33 ) -0 SEL RST +.025 2.95 (74.9) 1.71 2.68 .15 (3.8) -.000 (43.4) +8 (68 ) -0 1ORDERING INFORMATION TYPE MODEL NO. DESCRIPTION PART NUMBER CUB5TR Preset Timer and Cycle Counter with Reflective Display CUB5TR00 CUB5 CUB5TB Preset Timer and Cycle Counter with Backlight Display CUB5TB00 CUB5RLY Single Relay Option Card CUB5RLY0 Optional Plug-in Cards RS485 Serial Communications Card CUB5COM1 CUB5COM RS232 Serial Communications Card CUB5COM2 +12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out MLPS1000 MLPS +24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out MLPS2000 Accessories CBLPROG Programming Cable RS232 (RJ11-DB9) CBLPROG0 CBPRO Programming Cable RS485 (RJ11-DB9) CBPRO007 GENERAL METER SPECIFICATIONS 1. DISPLAY: 8 digit LCD 0.46 (11.7 mm) high digits and intensity level as per below: CUB5TR00: Reflective LCD with full viewing angle INTENSITY LEVEL TEMPERATURE CUB5TB00: Selectable transmissive red or green backlight LED with Red Display 1 & 2 -35 to 75C viewing angle optimized. Display color change capability at preset when 3 -35 to 70C using a relay module. 4 -35 to 60C 2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input 5 -35 to 50C polarity protection. Must use an RLC model MLPS or a Class 2 or SELV Green Display 1 & 2 -35 to 75C rated power supply. 3 -35 to 65C 4 -35 to 50C INPUT CURRENT INPUT CURRENT MODEL 5 -35 to 35C DISPLAY COLOR WITHOUT WITH NUMBER CUB5RLY0 CUB5RLY0 Storage Temperature: -35 to 85C Operating and Storage Humidity: 0 to 85% max. relative humidity (non- CUB5TR00 --- 10 mA 30 mA condensing) CUB5TB00 Red (max intensity) 85 mA 115 mA Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z CUB5TB00 Green (max intensity) 95 mA 125 mA direction for 1.5 hours, 5 g. 3. TIMER DISPLAY: 7-digits Shock According to IEC 68-2-27: Operational 40 g, 11 msec in 3 directions. Display Designator: t to the left side of the display Altitude: Up to 2000 meters Display Range: 0 to 9999999 10. CERTIFICATIONS AND COMPLIANCES: Overflow/Underflow Indication: Display flashes t OVEr SAFETY Minimum Digit Resolution: 0.001 Sec. UL Recognized Component, File E179259, UL61010A-1, CSA 22.2 No. 61010-1 Maximum Single Digit Resolution: 1 Hr. Recognized to U.S. and Canadian requirements under the Component Timing Accuracy: 0.01% Recognition Program of Underwriters Laboratories, Inc. 4. CYCLE COUNTER DISPLAY: 6-digits, may be disabled if not used UL Listed, File E137808, UL508, CSA C22.2 No. 14-M95 Display Designator: C to the left side of the display LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards Display Range: 0 to 999999 Type 4X Outdoor Enclosure rating (Face only), UL50 Overflow/Underflow Indication: Display flashes C OVEr IECEE CB Scheme Test Report E179259-V01-S02 Maximum Count Rate: Issued by Underwriters Laboratories, Inc. All Count Sources except Input B: 10 Hz IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment Input B Count Source: for measurement, control, and laboratory use, Part 1. With Timer Input Filter ON: 10 Hz IP65 Enclosure rating (Face only), IEC 529 With Timer Input Filter OFF: 500 Hz ELECTROMAGNETIC COMPATIBILITY 5. TIMER SIGNAL INPUTS (INP A and INP B) Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, Logic Inputs, Current Sinking (active low) Control and Laboratory use. Input A: Immunity to Industrial Locations: Internal 7.8K pull-up resistor to +9 to 28 VDC Electrostatic discharge EN 61000-4-2 Criterion A Trigger levels: V = 1.25 V max V = 2.75 V min V = 28 VDC IL IH MAX 4 kV contact discharge Input B: 8 kV air discharge Internal 10K pull-up resistor to +9 to 28 VDC Electromagnetic RF fields EN 61000-4-3 Criterion A Trigger levels: V = 0.7 V max V = 2.4 V min V = 28 VDC IL IH MAX 10 V/m Inputs A and B: Timer Input Pulse Width: 1 msec min. Fast transients (burst) EN 61000-4-4 Criterion A Timer Start/Stop Response Time: 1 msec max. 2 kV power Filter: Software filtering provided for relay or switch contact debounce. 1 kV signal Filter enabled or disabled through programming. If enabled, results in Surge EN 61000-4-5 Criterion A 50 msec start/stop response time for successive pulses applied to the 1 kV L-L, same input terminal. 2 kV L&N-E power 6. USER INPUT (USR): Programmable function input RF conducted interference EN 61000-4-6 Criterion A Logic Input, Current Sinking (active low) 3 V/rms Internal 10K pull-up resistor to +9 to 28 VDC Power frequency magnetic fields EN 61000-4-8 Criterion A Trigger levels: V = 0.7 V max V = 2.4 V min V = 28 VDC IL IH MAX 30 A/m Response Time: 5 msec typ. 50 msec debounce (activation and release) Emissions: 2 7. MEMORY: Nonvolatile E PROM memory retains all programming Emissions EN 55011 Class A parameters and timer/counter values when power is removed. Notes: 8. CONNECTIONS: Wire clamping screw terminals 1. Criterion A: Normal operation within specified limits. Wire Strip Length: 0.3 (7.5 mm) Refer to EMC Installation Guidelines for additional information. Wire Gage: 30-14 AWG copper wire 11. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for Torque: 5 inch-lbs (0.565 N-m) max. outdoor use. Installation Category I, Pollution Degree 2. High impact plastic 9. ENVIRONMENTAL CONDITIONS: case with clear viewing window. Panel gasket and mounting clip included. Operating Temperature Range for CUB5TR00: -35 to 75C 12. WEIGHT: 3.2 oz (100 g) Operating Temperature Range for CUB5TB00 depends on display color 2