Plug-in sockets and accessories Dimensions Connection diagrams GZT80 For RM84, RM85, NC RM85 inrush, RM85 105 C sensitive, COM RMB841, RMB851, NO RM87L, RM87L sensitive, RM87P, RM87P sensitive Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount COIL acc. to PN-EN 60715 RM84 RMB841 RM85 RM85 inrush RM87L RM87P or on panel mounting RM85 105 C sensitive 75,3 x 15,5 x 61(67) mm RMB851 Two poles, 5 mm pinout 12 A, 300 V AC GZT80-0040 GZT80-0035 Module type M... Accessories ZGGZ80 GZM80-0041 Dimensions Connection diagrams GZM80 For RM84, RM85, COM RM85 inrush, RM85 105 C sensitive, NO RMB841, RMB851, NC RM87L, RM87L sensitive, RM87P, RM87P sensitive Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount COIL acc. to PN-EN 60715 RM84 RMB841 RM85 RM85 inrush RM87L RM87P or on panel mounting RM85 105 C sensitive 78,1 x 15,9 x 61(66,5) mm RMB851 Two poles, 5 mm pinout 12 A, 300 V AC GZT80-0040 GZT80-0035 Module type M... Accessories ZGGZ80 GZM80-0041 Dimensions Connection diagrams GZS80 For RM84, RM85, COM RM85 inrush, RM85 105 C sensitive, NO RMB841, RMB851, RM87L, RM87L sensitive, RM87P, RM87P sensitive Screw terminals Max. tightening moment COIL for the terminal: 0,5 Nm 35 mm rail mount NC acc. to PN-EN 60715 RM84 RMB841 RM85 RM85 inrush RM87L RM87P or on panel mounting RM85 105 C sensitive 76,8 x 15,8 x 42,5(57,1) mm RMB851 Two poles, 5 mm pinout 10 A, 300 V AC GZS-0040 TR Module type M... ZGGZ80 GZM80-0041 Accessories Mounting and sub-assemblies of accessories in the socket - see page 9. Signalling / protecting modules type M... - see page 20. In the bracket the height of 1 socket with retainer / retractor clip is shown. For RM85, RM85 inrush, RM85 105 C sensitive, RMB851: loads above 12 A (GZT80, GZM80) or 10 A (GZS80, GZMB80) require bridging pairs of terminals: 11 with 21, 12 with 22, 14 with 24 - see www.relpol.com.pl For RMB841, RMB851 - see www.relpol.com.pl (energizing of bistable relays) www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014Plug-in sockets and accessories Dimensions Connection diagrams GZMB80 For RM84, RM85, NC RM85 inrush, RM85 105 C sensitive, COM 69 RMB841, RMB851, NO 45,2 RM87L, RM87L sensitive, RM87P, RM87P sensitive 16 36 Spring terminals Max. cross section of the cables: 2 1 x 0,2...1,5 mm COIL (1 x 24...16 AWG) RM84 RMB841 RM85 RM85 inrush RM87L RM87P Length of the cable RM85 105 C sensitive deinsulation: 9...11 mm RMB851 35 mm rail mount acc. to PN-EN 60715 97 x 16 x 45,2(69) mm Two poles, 5 mm pinout 10 A, 300 V AC 7,6 27 The drawings present the sequence of operations in course of inserting wires to the spring terminal, and the recommended screwdriver to be used for opening of case springs, comply with the DIN 5264 FORM A. GZMB80-0040 TR Module type M... GZM80-0041 Accessories Wire connection Pinout Dimensions EC 50 For RM84, RM85, RM85 inrush, RM85 105 C sensitive, RMB841, RMB851, RM87L, RM87L sensitive, RM87P, RM87P sensitive, RM83, RM94 For PCB 31,3 x 12,7 x 9 mm Two poles, 5 mm pinout 8 A, 300 V AC MP25-2 MH25-2 RM81-0001 Accessories MP16-2 MH16-2 GD-0025 Pinout Dimensions PW80 For RM84, RM85, RM85 inrush, RM85 105 C sensitive, RMB841, RMB851, RM87L, RM87L sensitive, RM87P, RM87P sensitive, RM83, RM94 For PCB 34,6 x 12,9 x 6,6 mm Two poles, 5 mm pinout 8 A, 250 V AC MH25-2 RM81-0001 Accessories MH16-2 GD-0025 Mounting and sub-assemblies of accessories in the socket - see page 9. Signalling / protecting modules type M... - see page 20. In the bracket the height of 2 socket with retainer / retractor clip is shown. For RM85, RM85 inrush, RM85 105 C sensitive, RMB851: loads above 12 A (GZT80, GZM80) or 10 A (GZS80, GZMB80) require bridging pairs of terminals: 11 with 21, 12 with 22, 14 with 24 - see www.relpol.com.pl For RMB841, RMB851 - see www.relpol.com.pl (energizing of bistable relays) www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 20,3 5,1 5,1 6 25,9 30,2 97 14.07.2014