PI6-1P interface relays Width 6,2 mm Interface relay PI6-1P - with 1 CO contact output 35 mm rail mount acc. to PN-EN 60715 May be linked with interconnection strip type ZG20 Equipped in LED green Version for long control lines, with anti-interference filter (PI6-1P-230VAC/DC-10 ) Recognitions, certifications, directives: : RoHS, Contact data Number and type of contacts 1 CO Contact material AgSnO2 AgSnO2/Au 3 m Max. switching voltage 400 V AC / 250 V DC 30 V AC / 36 V DC Min. switching voltage AC / DC 10 V 5 V Rated load AC1 6 A / 250 V AC 0,05 A / 30 V AC DC1 6 A / 24 V DC 0,15 A / 250 V DC 0,05 A / 36 V DC Min. switching current 100 mA 10 mA Max. inrush current 10 A 20 ms 0,1 A 20 ms Rated current 6 A 0,05 A Max. breaking capacity AC1 1 500 VA 1,2 VA Min. breaking capacity 1 W 0,05 W Contact resistance 100 m 100 mA, 24 V 30 m 10 mA, 5 V Max. operating frequency at rated load AC1 360 cycles/hour no load 72 000 cycles/hour Input circuit Rated voltage DC 12 ... 36 V AC: 50/60 Hz AC/DC 24 ... 230 V Must release voltage AC: 0,2 Un AC: 0,35 Un DC: 0,1 Un Operating range of supply voltage see Table 1 Must operate voltage AC and DC: 0,8 Un AC: 0,6...0,85 Un DC: 0,8 Un Input polarization current AC: 8 mA < Ip < 10 mA 230 V AC Rated power consumption DC 0,3 ... 0,7 W AC/DC 0,3 ... 1,6 VA / 0,3 ... 1,6 W Max. length of control line 300 m AC control voltage Insulation according to PN-EN 60664-1 Insulation rated voltage 400 V AC Rated surge voltage 4 000 V 1,2 / 50 s Overvoltage category III Insulation pollution degree 3 Dielectric strength input - output 4 000 V AC 50/60 Hz, 1 min., type of insulation: reinforced input - output 6 000 V 1,2 / 50 s mass - input, output 2 500 V AC 50/60 Hz, 1 min. contact clearance 1 000 V AC 50/60 Hz, 1 min., type of clearance: micro-disconnection Input - output distance clearance / creepage 6 mm / 8 mm General data Operating time (typical value) AC: 7 ms DC: 6 ms Release time (typical value) AC: 15 ms DC: 10 ms 5 Electrical life resistive AC1 > 0,6 x 10 6 A, 250 V AC 5 cos = 0,4 > 2 x 10 2 A, 250 V AC 5 resistive DC1 10 6 A, 30 V DC 7 Mechanical life (cycles) > 2 x 10 Dimensions (L x W x H) 93,8 x 6,2 x 80 mm Weight 40 g o Ambient temperature storage -40...+70 C o o operating -40...+55 C -40...+60 C 12, 24 V DC o o -40...+40 C 230 V AC -40...+50 C 230 V DC Protection category IP 20 PN-EN 60529 Environmental protection RTI PN-EN 116000-3 Shock / vibration resistance 10 g / 5 g 10...500 Hz The data in bold type pertain to the standard versions of the relays. For gold-plated contacts - when the maximum values given have been exceeded, the gold layer is destroyed. Then, the advantages of gold-plating disappear and the values are as for AgSnO2 contacts (see beside), and electrical life of these contacts may be shorter than of normal contacts. Refers version for long control lines (max. 300 m) PI6-1P-230VAC/DC-10 1 - relay with integrated anti-interference filter (desigend on the basis of appropriately selected elements R and C, and Zener diode), resistant to occur rence of induced voltages in long distances of control wires. www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014PI6-1P interface relays Input data Table 1 Input - voltage range Rated input Power Interface relay code V voltage Un of input circuit min. (at 20 C) max. (at 55 C) PI6-1P-12VDC 12 V DC 0,3 W 9,6 14,4 PI6-1P-24VDC 24 V DC 0,4 W 19,2 28,0 PI6-1P-36VDC 36 V DC 0,7 W 28,8 40,0 PI6-1P-24VAC/DC 24 V AC/DC 0,5 VA / 0,5 W 19,2 26,4 PI6-1P-42VAC/DC 42 V AC/DC 0,3 VA / 0,3 W 33,6 50,0 PI6-1P-115VAC/DC 115 V AC/DC 0,8 VA / 0,8 W 92,0 130,0 PI6-1P-230VAC/DC 230 V AC/DC 0,8 VA / 0,8 W 184,0 253,0 PI6-1P-230VAC/DC-10 230 V AC/DC 1,6 VA / 1,6 W 196,0 253,0 PI6-1P-12VDC-01 12 V DC 0,3 W 9,6 14,4 PI6-1P-24VDC-01 24 V DC 0,4 W 19,2 28,0 PI6-1P-36VDC-01 36 V DC 0,7 W 28,8 40,0 PI6-1P-24VAC/DC-01 24 V AC/DC 0,5 VA / 0,5 W 19,2 26,4 PI6-1P-230VAC/DC-01 230 V AC/DC 0,8 VA / 0,8 W 184,0 253,0 The data in bold type pertain to the standard versions of the relays. Version with gold-plated contacts. Version for long control lines (max. 300 m), with anti-interference filter. Connection diagrams Dimensions PI6-1P-12VDC, PI6-1P-12VDC-01 PI6-1P-24VDC, PI6-1P-24VDC-01 PI6-1P-36VDC, PI6-1P-36VDC-01 PI6-1P-24VAC/DC, PI6-1P-24VAC/DC-01 PI6-1P-42VAC/DC PI6-1P-115VAC/DC PI6-1P-230VAC/DC, PI6-1P-230VAC/DC-01 Inter connection strip type ZG20 PI6-1P-230VAC/DC-10 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014