PI85 with socket GZM80 interface relays RM85 + GZM80 Interface relay PI85 with socket GZM80 consists of: electromagnetic relay RM85, grey plug-in socket GZM80, signalling / protecting module: version LD - M41G or M43G (L - LED green, D - diode, polarization N: +A1/-A2) version LV - M91G or M93G (L - LED green, V - varistor), retainer / retractor clip GZT80-0040 (plastic), white description plate GZT80-0035 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with one M3 screw May be linked with interconnection strip type ZGGZ80 Recognitions, certifications, directives: recognitions RM85, RoHS, Contact data Number and type of contacts 1 CO Contact material AgNi Rated / max. switching voltage AC 250 V / 440 V Min. switching voltage 5 V Rated load (capacity) AC1 16 A / 250 V AC AC15 3 A / 120 V 1,5 A / 240 V (B300) AC3 750 W (single-phase motor) DC1 16 A / 24 V DC (see Fig. 3) DC13 0,22 A / 120 V 0,1 A / 250 V (R300) Min. switching current 5 mA Max. inrush current 30 A Rated current 16 A Max. breaking capacity AC1 4 000 VA Min. breaking capacity 0,3 W Contact resistance 100 m Max. operating frequency at rated load AC1 600 cycles/hour no load 72 000 cycles/hour Coil data Rated voltage 50/60 Hz AC 12 ... 230 V DC 12 ... 110 V Must release voltage AC: 0,15 Un DC: 0,1 Un Operating range of supply voltage see Tables 1, 2 and Fig. 4, 5 Rated power consumption AC 0,75 VA DC 0,4 ... 0,48 W Insulation according to PN-EN 60664-1 Insulation rated voltage 300 V AC Rated surge voltage 4 000 V 1,2 / 50 s Overvoltage category III Insulation pollution degree 3 Dielectric strength between coil and contacts 5 000 V AC type of insulation: reinforced contact clearance 1 000 V AC type of clearance: micro-disconnection Contact - coil distance clearance 10 mm creepage 10 mm General data Operating / release time (typical values) 7 ms / 3 ms Electrical life 5 resistive AC1 > 0,7 x 10 16 A, 250 V AC cos see Fig. 2 5 DC L/R=40 ms > 10 0,12 A, 220 V DC 7 Mechanical life (cycles) > 3 x 10 Dimensions (L x W x H) 78,1 x 15,9 x 66,5 mm Weight 59 g o Ambient temperature storage -40...+85 C o o operating AC: -40...+70 C DC: -40...+85 C Cover protection category IP 20 PN-EN 60529 Environmental protection RM85: RTII GZM80: RT0 PN-EN 116000-3 Shock resistance 30 g Vibration resistance 10 g 10...150 Hz The data in bold type pertain to the standard versions of the relays. Loads above 12 A require bridging pairs of terminals: 11 with 21, 12 with 22, 14 with 24 - see page 2. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014PI85 with socket GZM80 interface relays Coil data - DC voltage version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) 012DC 12 360 10% 8,4 30,6 024DC 24 1 440 10% 16,8 61,2 110DC 110 25 200 10% 77,0 280,0 The data in bold type pertain to the standard versions of the relays. Coil data - AC 50/60 Hz voltage version Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC 50 Hz V AC resistance min. (at 20 C) max. (at 20 C) 012AC 12 100 10% 9,6 13,2 024AC 24 400 10% 19,2 26,4 120AC 120 10 200 10% 96,0 144,0 230AC 230 38 500 10% 184,0 253,0 The data in bold type pertain to the standard versions of the relays. Dimensions Connection diagrams (screw terminals side view) Description Retainer / plate Socket Relay retractor clip GZT80-0035 GZM80 RM85 GZT80-0040 COM Module type M... NO NC COIL DC version AC version Connection of GZM80 socket Clamp bridge Cu wire 12 A, 300 V AC 2 min. 1,5 mm Inter con nection strip type ZGGZ80 Note: Loads above 12 A require bridging pairs of terminals: 11 with 21, 12 with 22, 14 with 24. Loads up to 12 A do not require bridging of common terminals (such bridges may be fixed, however). 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014