RM699B miniature relays Version (V) Version (H) Cover width only 5,0 mm Sealed for soldering and cleaning Terminals arrangement: vertical version (V) and horizontal version (H) Applications: for PLCs, industrial machinery, time relays, counters, temperature adjusters, measurement instruments, office equipment, etc. Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts 1 CO Contact material AgSnO2 AgSnO2/Au 3 m Max. switching voltage 400 V AC / 250 V DC 30 V AC / 36 V DC Min. switching voltage 10 V 5 V Rated load AC1 6 A / 250 V AC 0,05 A / 30 V AC DC1 6 A / 24 V DC 0,15 A / 250 V DC 0,05 A / 36 V DC Min. switching current 100 mA 10 mA Max. inrush current 10 A 20 ms 0,1 A 20 ms Rated current 6 A 0,05 A Max. breaking capacity AC1 1 500 VA 1,2 VA Min. breaking capacity 1 W 0,05 W Contact resistance 100 m 100 mA, 24 V 30 m 10 mA, 5 V Max. operating frequency at rated load AC1 360 cycles/hour no load 72 000 cycles/hour Coil data Rated voltage DC 5 ... 60 V Must release voltage DC: 0,05 Un Operating range of supply voltage see Table 1 Rated power consumption DC 0,17 W 5 ... 24 V 0,217 W 48, 60 V Insulation according to PN-EN 60664-1 Insulation rated voltage 250 V AC Overvoltage category III Dielectric strength between coil and contacts 4 000 V AC type of insulation: reinforced contact clearance 1 000 V AC type of clearance: micro-disconnection Contact - coil distance clearance 6 mm creepage 8 mm General data Operating / release time (typical values) 8 ms / 4 ms Electrical life (number of cycles) resistive AC1 the NO and NC contact loaded (bilateral load): see Fig. 1 4 the NO contact loaded: > 3 x 10 6 A, 250 V AC 7 Mechanical life (cycles) > 10 Dimensions (L x W x H) 28 x 5 x 15 mm Weight 6 g o Ambient temperature storage -40...+85 C o operating -40...+85 C Cover protection category IP 64 PN-EN 60529 Environmental protection RTIII PN-EN 116000-3 Shock resistance 5 g Vibration resistance 5 g 10...55 Hz o Solder bath temperature max. 260 C Soldering time max. 5 s The data in bold type pertain to the standard versions of the relays. For gold-plated contacts - when the maximum values given have been exceeded, the gold layer is destroyed. Then, the advantages of gold-plating disappear and the values are as for AgSnO2 contacts (see beside), and electrical life of these contacts may be shorter than of normal contacts. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014RM699B miniature relays Coil data - DC voltage version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) 1005 5 147 10% 3,75 7,5 1006 6 212 10% 4,5 9,0 1009 9 476 10% 6,75 13,0 1012 12 848 10% 9,0 18,0 1024 24 3 390 15% 18,0 36,0 1048 48 10 600 15% 36,0 72,0 1060 60 20 500 15% 45,0 90,0 Dimensions vertical version (V) horizontal version (H) Connection diagrams (pin side view) vertical version (V) horizontal version (H) 1 CO 1 CO 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014