RM92 miniature relays RM92 RM92-...-01 Miniature dimensions General purpose relays Protection category IP 40 or IP 67 For PCB and plug-in sockets DC coils - standard and sensitive Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts 1 CO, 1 NO, 1 NC Contact material AgCu/Au 0,2 m, AgCdO, AgCdO/Au 3 m Rated / max. switching voltage AC 250 V / 440 V Min. switching voltage 10 V AgCu/Au 0,2 m, 10 V AgCdO, 5 V AgCdO/Au 3 m Rated load AC1 8 A / 250 V AC DC1 8 A / 24 V DC Min. switching current 5 mA AgCu/Au 0,2 m, 5 mA AgCdO, 2 mA AgCdO/Au 3 m Rated current 8 A Max. breaking capacity AC1 2 000 VA Min. breaking capacity 0,5 W AgCu/Au 0,2 m, 0,5 W AgCdO, 0,05 W AgCdO/Au 3 m Contact resistance 100 m Max. operating frequency at rated load AC1 600 cycles/hour no load 72 000 cycles/hour Coil data Rated voltage DC 6 ... 80 V standard version 5 ... 60 V sensitive version Must release voltage DC: 0,1 Un Operating range of supply voltage see Tables 1, 2 Rated power consumption DC 0,8 W standard version 0,5 W sensitive version Insulation according to PN-EN 60664-1 Insulation rated voltage 400 V AC Dielectric strength between coil and contacts 4 000 V AC type of insulation: reinforced contact clearance 1 000 V AC type of clearance: micro-disconnection Contact - coil distance clearance 8 mm creepage 8 mm General data Operating / release time (typical values) 6 ms / 2 ms Electrical life (number of cycles) 5 resistive AC1 > 2 x 10 8 A, 250 V AC cos see Fig. 1 7 Mechanical life (cycles) > 3 x 10 Motor load according to UL 508 0,25 HP 120 V AC, single-phase motor Dimensions (L x W x H) IP 40: 28 x 11,5 x 26 mm IP 67: 28 x 11,5 x 26,5 mm Weight 17 g o Ambient temperature storage -40...+85 C o operating -40...+70 C Cover protection category IP 40 or IP 67 PN-EN 60529 Shock resistance 20 g Vibration resistance 10 g 10...150 Hz o Solder bath temperature max. 270 C Soldering time max. 5 s The data in bold type pertain to the standard versions of the relays. For special version - relays in transparent cover - see Ordering codes. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014RM92 miniature relays Coil data - DC voltage version, standard Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) 1006 6 58 10% 4,0 9,4 1012 12 170 10% 7,4 16,2 1024 24 740 10% 15,4 33,6 1036 36 1 600 10% 23,5 50,0 1048 48 3 200 10% 31,0 70,0 1060 60 5 000 10% 38,0 87,0 1080 80 10 000 10% 55,0 125,0 The data in bold type pertain to the standard versions of the relays. Coil data - DC voltage version, sensitive Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) S005 5 47 10% 3,2 8,5 S006 6 80 10% 4,2 11,0 S012 12 330 10% 8,3 22,5 S024 24 1 200 10% 16,8 43,0 S036 36 2 700 10% 25,0 64,0 S048 48 4 700 10% 32,8 85,0 S060 60 7 200 10% 42,0 105,0 Dimensions Connection diagrams (pin side view) 1 CO 1 NO 1 NC Terminal (pin) A1(1) 11(4) 12(3) 14(5) A2(2) mm 0,6 0,2 x 1 0,4 x 1 Drilling hole: for relays 1,3 + 0,1 mm for sockets 1,5 + 0,1 mm * - dimensions of version IP 67 Mounting Relays RM92 are designed for: direct PCB mounting plug-in sockets for PCB mounting EC 35 with clip MP25-2, MH25-2, GD-0025, RM81-0001 plug-in sockets GD35 with clip MP25-2, GD-0025, MH25-2, RM81-0001. 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014