RUC industrial relays of small dimensions Power relays of general application AC and DC coils Mounting: in sockets 35 mm rail mount acc. to PN-EN 60715 on panel PCB Versions: faston 187 (4,8 x 0,5 mm) faston 250 (6,3 x 0,8 mm) 3 mm con- tact gap (option - only in versions with normally open contacts) Additional features: K - test button L - light indicator (LED) Applications: control of electromagnets systems of heating, cooling, ventillation, air conditioning control with single-phase and three-phase motors catering industry machines and equipment automation systems photoelectric systems etc. with adaptor (V) with adaptor (H) Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts 2 CO, 3 CO, 2 NO, 3 NO 2 NO, 3 NO with contact gap 3 mm Contact material AgCdO, AgNi Rated / max. switching voltage AC 400 V / 440 V 230 V / 250 V Min. switching voltage 5 V AgNi, 10 V AgCdO Rated load AC1 16 A / 250 V AC or 10 A / 400 V AC 16 A / 250 V AC DC1 16 A / 24 V DC (see Fig. 3) Min. switching current 5 mA AgNi, 10 mA AgCdO Max. inrush current 40 A Rated current 16 A Max. breaking capacity AC1 4 000 VA Min. breaking capacity 0,3 W AgNi, 1 W AgCdO Contact resistance 100 m Max. operating frequency at rated load AC1 1 200 cykli/h no load 12 000 cykli/h Coil data Rated voltage AC 6 ... 240 V 50/60 Hz 400 V 50 Hz DC 6 ... 220 V Must release voltage AC: 0,15 Un DC: 0,1 Un Operating range of supply voltage see Tables 1, 2, 3, 4 Rated power consumption AC 2,8 VA 50 Hz 2,5 VA 60 Hz DC 1,5 W 1,7 W with contact gap 3 mm Insulation according to PN-EN 60664-1 Insulation rated voltage 400 V AC Rated surge voltage 4 000 V 1,2 / 50 s Overvoltage category III Insulation pollution degree 2 Dielectric strength between coil and 2 500 V AC type of insulation: basic contacts 1 500 V AC type of clearance: micro-disconnection contact clearance 2 500 V AC with contact gap 3 mm, type of clearance: full-disconnection pole - pole 2 500 V AC type of insulation: basic Contact - coil distance clearance 5 mm 2 CO, 2 NO 4 mm 3 CO, 3 NO creepage 8 mm 2 CO, 2 NO 5 mm 3 CO, 3 NO General data Operating / release time (typical values) 20 ms / 15 ms 5 5 Electrical life resistive AC1 > 10 16 A, 250 V AC > 10 10 A, 400 V AC cos see Fig. 2 7 Mechanical life (cycles) > 10 Motor load according to UL 508 2 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor 3 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor 3 CO: 0,5 HP 240 V AC, three-phase motor Dimensions (L x W x H) RUC faston 4,8 x 0,5 RUC faston 6,3 x 0,8 Weight 80 g 85 g o Ambient temperature storage -40...+85 C o o operating AC: -40...+55 C 3 CO, 3 NO / 16 A (+70 C 2 CO, 2 NO / 16 A) o o DC: -40...+55 C 3 CO, 3 NO / 16 A (+70 C 3 CO, 3 NO / 10 A 2 CO, 2 NO / 16 A) Cover protection category IP 00 PN-EN 60529 Shock / vibration resistance 10 g / 5 g 10...150 Hz o Solder bath temperature max. 270 C Soldering time max. 5 s The data in bold type pertain to the standard versions of the relays. For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC / DC. For plug-in sockets version: 36,1 x 38,6 x 45,5 mm. For version: with (V) adaptor: 58,75 x 38,6 x 45,9 mm with (H) adaptor: 46,8 x 38,6 x 62,45 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. For PCB version: 36,1 x 38,6 x 52,5 mm. For version: with (V) adaptor: 62,4 x 38,6 x 45,9 mm with (H) adaptor: 46,8 x 38,6 x 66,1 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. Weight of plug-in sockets version and PCB version (RUC faston 4,8 x 0,5). Weight of version with (V) or (H) 1 adaptor, and version with mounting flange. www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014RUC industrial relays of small dimensions Coil data - DC voltage version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 55 C) 1006 6 28 10% 4,8 6,6 1012 12 110 10% 9,6 13,2 1024 24 430 10% 19,2 26,4 1042 42 1 340 10% 33,6 46,2 1048 48 1 750 10% 38,4 52,8 1060 60 2 700 10% 48,0 66,0 1110 110 9 200 10% 88,0 121,0 1120 120 11 000 10% 96,0 132,0 1220 220 37 000 10% 176,0 242,0 The data in bold type pertain to the standard versions of the relays. Coil data - DC voltage version, reinforced Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 55 C) W012 12 85 10% 9,6 13,2 W024 24 345 10% 19,2 26,4 W048 48 1 370 10% 38,4 52,8 W110 110 7 300 10% 88,0 121,0 W220 220 30 000 10% 176,0 242,0 For version with contact gap 3 mm. Coil data - AC 50/60 Hz voltage version Table 3 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC V AC resistance min. (at 20 C) max. (at 55 C) 5006 6 4,3 10% 4,8 6,6 5012 12 18,5 10% 9,6 13,2 5024 24 75 10% 19,2 26,4 5115 115 1 840 10% 92,0 126,5 5120 120 1 910 10% 96,0 132,0 5220 220 6 980 10% 176,0 242,0 5230 230 7 080 10% 184,0 253,0 5240 240 7 760 10% 192,0 264,0 Coil data - AC 50 Hz voltage version Table 4 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC V AC resistance min. (at 20 C) max. (at 55 C) 3400 400 21 500 10% 320,0 440,0 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014