Additional Resources: Product Page date 08/21/2012 page 1 of 5 SERIES: EMSA 6W DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 6 W power interchangeable AC blades universal input (90~264 Vac) single regulated output from 5~15 V over voltage and short circuit protections UL/cUL, GS, RCM, CCC, PSE safety approvals level V efficiency custom designs available RoHS output output output ripple ef ciency MODEL 1 voltage current power and noise level max max max (Vdc) (A) (W) (mVp-p) EMSA050120 5 1.2 6 150 V EMSA090067 9 0.67 6 150 V EMSA120050 12 0.50 6 120 V EMSA150040 15 0.40 6 150 V Notes: 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 F aluminum electrolytic and 0.1 F ceramic capacitors. PART NUMBER KEY EMSA120050 X - XX - SZ - CXX Base Number Reserved for Custom example of 12 Vdc, 0.5 A Con gurations DC Plug Type Factory Designation Blades: blank = North American, European, United Kingdom, Australian, and China blades included N = North American blade included E = European blade included B = United Kingdom blade included A = Australian blade included C = China blade included K = No blades included cui.com DISCONTINUEDAdditional Resources: Product Page CUI Inc SERIES: EMSA 6W DESCRIPTION: AC-DC POWER SUPPLY date 08/21/2012 page 2 of 5 INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current 0.3 A RMS 9 V output at 115 V ac, cold start 15 A 9 V output at 230 V ac, cold start 30 A inrush current all other outputs: 115 V ac, cold start 30 A all other outputs: 230 V ac, cold start 60 A no load power consumption 0.3 W OUTPUT parameter conditions/description min typ max units line regulation 3 % load regulation 5 % PROTECTIONS parameter conditions/description over voltage protection protect through primary circuit IC short circuit protection output shut down and auto restart SAFETY & COMPLIANCE parameter conditions/description min typ max units 3,000 Vac isolation voltage input to output at 10 mA for 1 minute 4,242 Vdc isolation resistance input to output at 500 V dc 100 M safety approvals UL 60950-1, EN 60950-1/IEC 60950-1, RCM, CCC, PSE EMI/EMC FCC Part 15B, EN 55022B, CE 9 V output 0.25 mA leakage current all other outputs 0.1 mA RoHS compliant yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 040C storage temperature -10 70 C operating humidity 20 80 % storage humidity 10 90 % cui.com DISCONTINUED