2017 ROHM Co., Ltd. No. 60AP001E Rev.001 2017.4 User s Guide Switching Regulator Series Step-Down DC/DC Converter BD9E100FJ-LB Evaluation Board BD9E100FJ-EVK-001 BD9E100FJ-EVK-001 Evaluation board delivers an output 5.0 volts from an input 7.2 to 33 volts using BD9E100FJ-LB, a synchronous rectification step-down DC/DC converter integrated circuit, with output current rating of maximum 1A. The output voltage can be set by changing the external parts of circuit and the loop-response characteristics also can be adjusted by the phase compensation circuit. Performance specification These are representative values, and it is not a guaranteed against the characteristics. VIN = 24V, VOUT = 5.0V, Unless otherwise specified. Parameter Min Typ Max Units Conditions (NOTE1) (NOTE2) Input Voltage Range 7.0 36 V Output Voltage 5.0 V R1=12k, R2=3k (NOTE3) Output Voltage Setting Range V 0.15 V 0.7 V IN IN Output Current Range 0 1 A Loop Band Width 44.7 kHz Phase Margin 68.9 degrees Input Ripple Voltage 60 mVpp I = 1A O Output Ripple Voltage 40 mVpp IO = 1A Output Rising Time 3 ms Operating Frequency 1.0 MHz Maximum Efficiency 83.5 % I = 0.6A O (NOTE1) When the output voltage is 5.0V, it is 7.2V by limiting ratio of the maximum duty. (NOTE2) When the output voltage is 5.0V, it is 33V by limiting ratio of the minimum duty. (NOTE3) However, (V 0.15) 1.0V IN 2014 ROHM Co., Ltd. No. 60UG010E Rev.003 1/10 APR.2017 BD9E100FJ-EVK-001 User s Guide Operation Procedures 1. Necessary equipments (1) DC power-supply of 7.2V to 33V/1A (2) Maximum 1A load (3) DC voltmeter 2. Connecting the equipments (1) DC power-supply presets to 24V and then the power output turns off. (2) The maximum load should be set at 1A and over it will be disabled. (3) Check Jumper pin of SW1 is short, between intermediate-terminal and OFF-side terminal. (4) Connect positive-terminal of power-supply to VIN+ terminal and negative-terminal to GND-terminal with a pair of wires. (5) Connect loads positive-terminal to VOUT+ terminal and negative-terminal to GND-terminal with a pair of wires. (6) Connect positive-terminal of DC voltmeter 1 to TP1 and negative-terminal to TP2 for input-voltage measurement. (7) Connect positive-terminal of DC voltmeter 2 to TP3 and negative-terminal to TP4 for output-voltage measurement. (8) DC power-supply output is turned ON. (9) IC is enable (EN) by shorting Jumper-pin of SW1 between intermediate-terminal and ON-side terminal. (10) Check DC voltmeter 2 displays 5.0V. (11) The load is enabled. (12) Check at DC voltmeter 1 whether the voltage-drop (loss) is not caused by the wires resistance. + Load - + DC Voltmeter 1 V + - V DC Voltmeter 2 - - DC Power + Figure 1. Connection Diagram Enable-Pin To minimize current consumption during standby-mode and normal operation, Enable-mode can be switched by controlling EN pin (3pin) of the IC. Standby-mode is enabled by shorting Jumper-pin of SW1 between intermediate-terminal and OFF-side terminal and normal-mode operation by shorting between intermediate-terminal and ON-side terminal. It also can be switched between standby-mode and normal-mode operation by removing Jumper-pin and controlling the voltage between EN and GND-terminal. Standby-mode is enabled when the voltage of EN is under 0.8V, and normal-mode operation when it is over 2.5V. 2014 ROHM Co., Ltd. No. 60UG010E Rev.003 2/10 APR.2017