+ Data Sheet Data Sheet 100VAC Input/12VDC (300mA) Output 100VAC Input/12VDC (500mA) Output Non-Isolated AC/DC Converter Non-Isolated AC/DC Converter BP5061 BP5062A Absolute Maximum Ratings Dimensions (Unit : mm) Absolute Maximum Ratings Dimensions (Unit : mm) 9.1MAX. Parameter Symbol Limits Unit 35.0MAX. Parameter Symbol Limits Unit 9.9MAX. 34.5MAX. Input voltage Vi 170 V Input voltage Vi 190 V Output current Io 300 mApk Output current Io 500 mA ESD endurance Vsurge 2 kV ESD endurance Vsurge 2 kV 1 3 5 7 10 1 1 3 5 7 8 10 12 Operating temperature range Topr 25 to +80 C Operating temperature range Topr 20 to +80 C 0.250.0 5 + 0.25 0.05 0.50.1 Storage temperature range Tstg 25 to +105 C 1.30.2 Storage temperature range Tstg 25 to +105 C + 0.5 0.1 + 1.3 0.2 5.080.2 7.620.3 4.85MAX. + 3.6MAX P=5.08 0.2 5.05MAX. 3.3MAX 2.5411=27.94 4.25MAX. 2.54 11=27.94 4.85MAX. Electrical Characteristics Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Conditions Parameter Symbol Min. Typ. Max. Conditions Derating Curve Unit Derating Curve V DC (80 to 127VAC) Input voltage range Vi 113 141 170 DC (80 to 120VAC) Input voltage range Vi 113 141 180 V Derating Curve 350 V Vi= 141V, Io=300mA Output voltage Vo 11.0 12.0 13.0 Vi=141V, Io=200mA Output voltage Vo 11.0 13.0 V Derating Curve 300 12.0 600 250 mA Output current Io 0 300 Vi=141V 1 Output current Io 0 500 mA Vi= 141V 1 500 200 V 400 Line regulation Vr 0.04 0.15 Vi=113V to 170V, Io=200mA 150 Line regulation Vr 0.15 V Vi= 113V to 170V, Io=300mA 0.05 Operation Range 100 300 V Operation Range Load regulation Vl 0.05 0.15 Vi=141V, Io=0 to 200mA Load regulation Vl 0.20 V Vi= 141V, Io=0 to 300mA 0.07 50 200 Vp-p 0 Output ripple voltage Vp 0.07 0.15 Vi=141V, Io=200mA Output ripple voltage Vp 0.15 Vp-p 2 0.05 Vi= 141V, Io=300mA 2 100 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 % Ambient Temperature Ta(C) 0 Power conversion efficiency 70 78 Vi=141V, Io=300mA Power conversion efficiency % 75 83 Vi= 141V, Io=500mA -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta( C) 1 Maximum output current varies depending on ambient temperature please refer to derating curve. 1 Maximum output current varies depending on ambient temperature please refer to derating curve. 2 Spike noise is not included in output ripple voltage. 2 Spike noise is not included in output ripple voltage. Conversion Efficiency Conversion Efficiency Conversion Efficiency (Ta=25C, Vi=141V) 100 Conversion Efficiency Application Circuit 90 Application Circuit (Ta=25 C, Vi= 141V) 100 80 Pin No. Function Pin No. Function 90 70 1 Output terminal Vo(12V) 1 Output terminal Vo( 12V) 80 BP5061 60 2 Not used BP5062A 2 Not used 70 50 3 Coil connect 3 Coil connect 40 60 4 Not used Not used 4 50 Please note that pin No.12 30 5 Coil connect Please note that pin No.12 5 Coil connect 40 20 Not used side is input. 6 Not used 6 side is input. 30 10 7 COMMON 7 COMMON 20 0 8 Not used COMMON 0 50 100 150 200 250 300 8 10 9 Not used 9 Not used Output Current Io(mA) 0 10 N.C. 12 10 7 5 3 1 0 100 200 300 400 500 10 N.C. 12 10 8 7 5 3 1 11 Not used Output Current Io(mA) 11 Not used FUSE FUSE R1 12 Input voltage Vi(141VDC) Output 12 Input terminal Vi( 141VDC) 1A R1 2A Output D1 101/4W D1 Load Regulation 12V 10 1/4W 12V L1 L1 Load Regulation Load Regulation Input C2 C3 1mH Input ZNR C2 470H C3 C1 (Ta=25C, Vi=141V) ZNR C1 13.0 AC100V + + AC100V 220V Load Regulation 0.1F + + 220V 33F/200V 100F/50V 47F/200V 0.1F 220F/50V (Ta=25C, Vi=141V) 50Hz/60Hz 50Hz/60Hz 14 12.5 12 Be sure to use fuse for safety. Be sure to use fuse for safety. 10 12.0 Please verify operation and characteristics in the customer s circuit before actual usage. Please verify operation and characteristics in the customer s circuit before actual usage. 8 11.5 Ensure that the load current does not exceed the maximum rating. 6 Ensure that the load current does not exceed the maximum rating. 4 11.0 2 0 50 100 150 200 250 300 Output Current Io(mA) 0 External Component Specifications 0 100 200 300 400 500 600 700 800 900 External Component Specifications Output Current Io(mA) FUSE: Fuse Use a quick-acting fuse of 1A FUSE: Fuse Use a quick-acting fuse of 2A Surface Temperature Increase C1: Input smoothing Capacitance : 22 to 100F Rated voltage : 200V or higher C1: Input smoothing Capacitance : 22 to 47F Rated voltage : 200V or higher Surface Temperature Increase Surface Temperature Increase capacitor Ripple current is 0.13Arms or greater. (Ta=25C, Vi=141V) capacitor Ripple current is 0.22Arms or greater. 50 Surface Temperature Increase 45 (Ta=25C, Vi=141V) Capacitance : 0.1 to 0.22F Rated voltage : 200V or higher C2: Noise reduction 40 C2: Noise reduction Capacitance : 0.1F to 0.22F Rated voltage : 200V or higher 50 Use a film or ceramic capacitor. Evaluate under actual 35 45 capacitor capacitor Use a film or ceramic capacitor. Evaluate under actual 40 30 conditions. 35 25 operating conditions. 20 30 C3: Output smoothing Capacitance : 100 to 470F Rated voltage : 25V or higher, 25 15 C3: Output smoothing Capacitance : 220F to 820F Rated voltage : 25V or higher, 20 10 capacitor ECR is 0.4 max. Ripple current is 0.25Arms or higher. capacitor ESR is 0.15 max. Ripple current is 1.0Arms or greater. 5 15 Evaluate under actual operating conditions. 0 10 Evaluate under actual operating conditions. 0 50 100 150 200 250 300 350 5 D1: Rectifier diode In the absolute maximum ratings, the reverse peak voltage should be Output Current Io(mA) 0 D1: Rectifier diode In the absolute maximum ratings, the reverse peak voltage should be 0 50 100 150 200 250 300 350 400 450 500 400V or higher, the average rectifying current should be 1A or higher, Output Current Io(mA) 400V or higher, the average rectifying current should be 1A or higher, and the peak surge current should be 20A or higher. and the peak surge current should be 40A or higher. (Full-wave rectification can be used.) (Full-wave rectification can be used.) Coil for switching regulator. The inductance should be 1mH, L1: Choke coil Coil for switching regulator. The inductance should be 470H, L1: Choke coil the rated direct current should be 0.6A or greater in order to prevent the rated direct current should be 1.0A or greater in order to prevent overheating or abnormal oscillation. overheating or abnormal oscillation. 10 to 22 1/4W R1: Noise reduction 10 to 22 1/4W R1: Noise reduction resistor Determine the ideal value through actual testing. Determine the ideal value through actual testing. resistor A varistor is required to protect against lightning surges and ZNR: Varistor A varistor is required to protect against lightning surges and static ZNR: Varistor static electricity. electricity. www.rohm.com 2010.01 - Rev.A 2010 ROHM Co., Ltd. All rights reserved. 1/1 Output Current Io(mA) Temperature Rising T(C) Output Voltage Vo(V) Conversion Efficiency (%) 41.0 19.5MAX. Mark Side Output Current Io(mA) Temperature Rising T(C) Output Voltage Vo(V) Conversion Efficiency (%) 4 1.0+ 21.5MAX. Mark Side