Data Sheet Data Sheet 100VAC Input/5VDC (30mA) Output 100VAC Input/5VDC (200mA) Output Non-Isolated AC/DC Converter Non-Isolated AC/DC Converter BP5038A1 BP5063-5 Absolute Maximum Ratings Absolute Maximum Ratings Dimensions (Unit : mm) Dimensions (Unit : mm) 9.1MAX. 28.2MAX. Unit Parameter Symbol Limits Unit Parameter Symbol Limits 18.0MAX. 9.1MAX. Input voltage Input voltage Vi V Vi 170 V 170 Output current Io 30 mApk Maximum Output current Iomax 200 mApk ESD endurance ESD endurance Vsurge 2 kV Vsurge 2 kV 10 7 5 3 2 1 1 4 5 6 Operating temperature range Operating temperature range Topr 20 to +80 C Topr 25 to +80 C 0.25 0.05 0.250.05 P=2.540.2 0.5 1.4 Storage temperature range Tstg 20 to +85 C Storage temperature range Tstg 25 to +105 C 1.30.2 3.0MAX. 2.54 4.85MAX. 3.3MAX. 0.50.1 3.3MAX Maximum surface temperature Tcmax C 2.549=22.86 4.25MAX. 105 2.545=12.7 6.1MAX. Electrical Characteristics Electrical Characteristics Derating Curve Derating Curve Parameter Symbol Min. Typ. Max. Conditions Unit Parameter Symbol Min. Typ. Max. Unit Conditions Derating Curve Derating Curve 240 40 V Input voltage range Vi 113 141 170 DC(80 to 120VAC) 35 Input voltage range Vi 113 141 170 V DC(80 to 120VAC) 200 30 V Output voltage Vo 4.7 5.0 5.3 Vi=141V, Io=15mA 160 Output voltage Vo 4.7 5.0 5.3 V Vi=141V, Io=100mA 25 120 20 mA Output current Io 0 30 Vi=141V 1 Operation Range Output current Io 0 200 mA Vi=141V Operation Range 1 15 80 V 10 Line regulation Vr 0.1 0.3 Vi=113 to 170V, Io=15mA Line regulation Vr 0.05 0.15 V Vi=113 to 170V, Io=100mA 40 5 V Load regulation Vl 0.15 0.3 Vi=141V, Io=0 to 15mA 0 2 0 Load regulation Vl 0.07 0.20 V Vi=141V, Io=0 to 100mA -30 -20 -10 0 10 20 30 40 50 60 70 80 90 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Vp-p Output ripple voltage Vp 0.05 0.15 Vi=141V, Io=15mA Ambient Temperature Ta(C) Ambient Temperature Ta(C) Output ripple voltage Vp 0.05 0.15 Vp-p Vi=141V, Io=100mA 2 % Power conversion efficiency 25 33 Vi=141V, Io=30mA 2 Power conversion efficiency 50 62 % Vi=141V, Io=200mA Switching Frequency 1 Maximum output current varies depending on ambient temperature please refer to derating curve. Switching Frequency 1 Maximum output current varies depending on ambient temperature please refer to derating curve. 2 Please refer to Load regulation, Conversion efficiency. 2 Spike noise is not included in output ripple voltage. Switching Frequency Switching Frequency (Ta=25C, Vi=141V) 40 60 35 50 30 Application Circuit Application Circuit 40 25 Pin No. Function Pin No. Function 20 30 1 Input terminal Vi(141VDC) 1 Output terminal Vo(5V) BP5038A1 BP5063-5 15 2 N.C. 2 Skip 20 10 3 Skip 3 Choke coil connect 10 5 Please note that pin No.10 4 Not used 4 COMMON 0 0 5 COMMON 5 Choke coil connect side is input. 0 50 100 150 200 0 5 10 15 20 25 30 6 Not used 6 Output terminal Vo(5V) Output Current(mA) Output Current Io(mA) 7 COMMON 8 Not used 10 7 5 3 1 1 4 5 6 9 Not used Conversion Efficiency Conversion Efficiency FUSE FUSE R1 10 Input terminal Vi(141VDC) R1 Output 1A D1 0.5A D1 101/4W Conversion Efficiency Conversion Efficiency 1SR35400A +5V 101/4W (Ta=25C, Vi=141V) (Ta=25C, Vi=141V) L1 100 40 Input C2 C3 Input C2 C3 + + 90 + + ZNR ZNR 820H 35 AC100V C1 C1 80 AC100V 330F/25V 100F/50V 30 0.1F 220V 0.1F 50Hz/60Hz 220V 22F/200V 70 10F/200V 50Hz/60Hz 25 60 25% MinLine 50 20 Be sure to use fuse for safety. 40 Be sure to use fuse for safety. 15 30 10 20 Please verify operation and characteristics in the customer s circuit before actual usage. Please verify operation and characteristics in the customer s circuit before actual usage. 5 10 Ensure that the load current does not exceed the maximum rating. Ensure that the load current does not exceed the maximum rating. 0 0 0 50 100 150 200 0 5 10 15 20 25 30 Output Current Io(mA) Output Current Io(mA) External Component Specifications External Component Specifications FUSE: Fuse Use a quick-acting fuse (0.5A) Load Regulation Load Regulation FUSE: Fuse Use a quick-acting fuse 1A C1: Input capacitor Above 200V, 3.3 to 22F Load Regulation Load Regulation C1: Input smoothing Capacitance : 22 to 100F Rated voltage : 200V or higher (Ta=25C, Vi=141V) (Ta=25C, Vi=141V) Ripple current 0.13Arms or above. 5.3 5.3 capacitor Ripple current is 0.13Arms above. 5.2 5.2 C2: Noise removal capacitor Above 200V, 0.1 to 0.22F Capacitance : 0.1 to 0.22F Rated voltage : 200V or higher C2: Noise reduction 5.1 5.1 Film or ceramic capacitor capacitor Use a film or ceramic capacitor to reduce voltage noise. 5.0 5.0 Reduce the noise terminal voltage. Evaluate under actual conditions before use. 4.9 4.9 The value should be verified under actual conditions. C3: Output smoothing Capacitance : 100 to 470F Rated voltage : 16V or higher, 4.8 4.8 C3: Output capacitor Above 25V, 100 to 470F, low impedance capacitor ESR is 0.25 max. Ripple current is 0.25Arms or above. 4.7 4.7 ESR : 0.39 Max. 0 5 10 15 20 25 30 0 50 100 150 200 Evaluate performance in actual set. Output Current Io(mA) Output Current Io(mA) Ripple current 0.1Arms or above D1: Rectifier diode In the absolute maximum ratings, the reverse peak voltage should be Capacitor impedance affects the output ripple voltage. 400V or higher, the average rectifying current should be 0.5A or higher, Surface Temperature Increase Surface Temperature Increase R1: Noise removal resistor Resistance : 10 to 22, Power : More than 1/4 and the peak surge current 20A or higher. Surface Temperature Increase Surface Temperature Increase (Full-wave rectification can be used.) D1: Rectifier diode Use a rectifying diode with a peak reverse voltage of 400V or higher, (Ta=25C, Vi=141V) (Ta=25C, Vi=141V) 40 50 Coil for switching regulator. The inductance should be 820H, an average rectification current of 0.5A or larger and a large capacity input L1: Choke coil 35 40 the rated direct current should be 0.42A or above in order to capacitor, peak surge current of 20A or larger. When using a large capacity 30 prevent abnormal heating or oscillation. 25 input capacitor, choose a component that is strong against inrush current 30 20 10 to 22 1/4W during startup. R1: Noise reduction 20 15 resistor Optional for voltage noise reduction. Determine the ideal value through This product is compatible with full-wave rectification. 10 10 actual evaluation. 5 ZNR: Varistor A varistor must be used to protect against lightning surges and static 0 0 ZNR: Varistor A varistor must be used to protect the part from lightning surges and 0 20 40 60 80 100 120 140 160 180 200 electricity. 0 5 10 15 20 25 30 static electricity. Output Current Io(mA) Output Current Io(mA) www.rohm.com 2010.01 - Rev.A 2010 ROHM Co., Ltd. All rights reserved. 1/1 Output Current Io(mA) Output Voltage Vo(V) Temperature Rising T(C) Conversion Efficiency (%) Switching Frequency fsw(kHz) 41.0 16.8MAX. Mark Side Output Current Io(mA) Temperature Rising T(C) Switching Frequency tsw(kHz) Output Voltage Vo(V) Conversion Efficiency (%) 41.0 17.9MAX. Mark Side