F-219 (Rev 11NOV19) IDMD24D12.00G (2.54 mm) .100 SLIM BODY FLAT RIBBON IDC CABLES Mates with: SPECIFICATIONS TSW, MTSW, TSM, EJH, TYPE ROW NO. PINS END PHT, HMTSW, HTSW, STRIP OPTION PER ROW ASSEMBLY For complete specifications see www.samtec.com IDSS, HW, DW, EW, ZW, www.samtec.com IDSD, MTLW www.samtec.com IDMS or www.samtec.com IDMD IDSD Mates with: Single S = S TST, HTST, ZST, End Insulator Material: = Single Black Glass Filled Polyester BST, EJH Plating: Au over 50 (1.27 m) Ni or D Sn over 100 (2.54 m) Cu = Double or 50 (1.27 m) Ni (Color coded Wire: IDM 28 AWG 7/36 stranded cable N/A for = Standard Tail Male Plug Tinned Copper 31 thru 36 Temperature Range: pins/row. Socket or Male Plug on one end -20 C to +105 C See G IDS (Rainbow Cable) option.) = Socket -40 C to +105 C Double = D (Gray Cable) End Voltage Rating: 425 VAC/600 VDC Contact (IDSS/IDSD): BeCu Terminal (IDMS/IDMD): 02 thru 32 Phosphor Bronze Current Rating (IDSD/TST): 3.4 A per pin DOUBLE (2 pins powered) Full size (64 positions): IDMD IDMS Current Rating (IDMD): (82.55) 3.250 Less than 64 positions: 3 A per pin (Double) (Single) No. Positions/row X (2.54) .100 + (1.68) .066 (2 pins powered) Socket or Male Plug on each end Lead Size Range: SINGLE Full size (32 positions): (0.56 mm) .022 SQ to (81.53) 3.210 (0.71 mm) .028 SQ Less than 32 positions: (2.54) (5.08) Transfer = Lead Insertion Depth: No. Positions/row X (2.54) .100 + (0.71) .028 .100 .200 T End (5.59 mm) .220 to (6.22 mm) .245 (6.10) RoHS Compliant: .240 MAX Yes (0.48) (3.18) RECOGNITIONS .019 .125 (0.46) (2.54) Male Plug on one end with socket on For complete scope (2.54) .100 .018 .100 other. Begin part number with IDM. of recognitions see x www.samtec.com/quality (0.48) .019 (For square or long tail see HCMX Series) OTHER SOLUTIONS FILE NO. E111594 02 thru 36 Molded-To-Position IDC Assemblies Low profile DOUBLE Full size (72 positions): Skinny side locks (92.71) 3.650 Less than 72 positions: Dual beam contacts IDSD IDSS No. Positions/row x (2.54) .100 + (1.50) .059 Single and double row (Double) (Single) SINGLE (3.05 mm) .120 Full size (36 positions): (91.69) 3.610 and (5.84 mm) .230 Less than 36 positions: (5.08) No. Positions/row x (2.54) .100 + (0.48) .019 .200 length tail available (9.27) .365 REF (0.76) (2.54) (2.54) .030 .100 .100 SQ Note: This Series is non-standard, non-returnable. Due to technical progress, all designs, specifications and components are subject to change without notice. WWW.SAMTEC.COM All parts within this catalog are built to Samtecs specifications. Customer specific requirements must be approved by Samtec and identified in a Samtec customer-specific drawing to apply.IDSD05D04.25S02 IDSD24S05.00 IDSS, IDSD, IDMS, IDMD SERIES SLIM BODY FLAT RIBBON IDC CABLES EJECTOR HEADERS ASSEMBLED OPTION & LOCKING CLIPS LENGTH IDSS or IDSD STRIP ASSEMBLY Ejector headers Locking clips XX.XX POLARIZING KEY LOCKING = Assembled Length CLIP .025 SQ (0.64) .025 Optional polarizing key for TERMINAL SQ PC use with IDSS & IDSD STRIP (TSW) Assembled Length in BOARD 1 (5.84) INCHES ( /8 ) Series. Also polarizes .230 (2 inches minimum) SSW, SSQ, ESW & ESQ Series. Black High See TSW Series. Temperature Thermoplastic Order: Part Number PK-01-06 See EJH Series. (Available in wheels of six each) Tin Plating = T (Both ends) ST X S XX RR = Stripped & Tinned = Daisy Chain Single = Re= Reverversedsed Tin IDM Specify Suffix from table. 2 10 (0.25 m) Gold IDS 1 C = XX 8 min. All dimensions are 1/16 . Single Row (-T End Assembly Required) Not available in 28 positions and higher. Connectors (IDSS) 10 (0.25 m) Gold IDM A = Tin IDS (-T End Assembly Required) Outer Most Standard plating is selective 4 minimum gold over BeCu contact for IDS When mating double row Selective gold over phosphor 8 connector with two single row bronze for IDM. 1 1/8 (3.18) ST8 connectors, the outer most 1/4 (6.35) ST4 single will be connected to M 1/2 (12.70) = Middle Reversed P XX ST2 Conductor 1 and the inside =Polarized 3/8 (9.53) ST3 single to Conductor 2. 4 7 72 04 02 D XX B XX = Daisy Chain, Double = Breakout 71 03 01 Specify XX as number of 2 1 XX 8 conductors to be broken out. Specify XX as position. For min. Requires SXX, WXX or DXX Double Row Double the same position will Connectors (IDSD or be polarized on both ends. 8 IDMD) (Not available on IDM unless transfer, then only the socket O Outer Most is polarized.) 2 XX = Outside Reversed 4 minimum G 5 max. 7 = Gray Cable 2 min. Breakout starts with Number 1 lead indicated Specify G for Gray cable. Gray W XX by brown wire or red stripe. cable has one red edge. IDSS = Wiring Reversed Shown on top side. 5 and IDMS uses .100 centerline Daisy Chain, Single cable. IDSD and IDMD uses .050 centerline cable. Cable is RW Same as S XX except outer = Reversed Wiring 28 AWG 7/36 copper wire. Requires SXX, WXX or DXX strip connected to Conductor Standard cable is same as 2 and inside strip connected above except color coded. 1 wire opposite position 1. to Conductor 1. 3 6 7 8 Due to technical progress, all designs, specifications and components are subject to change without notice. WWW.SAMTEC.COM All parts within this catalog are built to Samtecs specifications. Customer specific requirements must be approved by Samtec and identified in a Samtec customer-specific drawing to apply.