AC Fan 160 160 51 mm San Ace 160 Only standard fans (without sensors) have acquired CSA certification. General Specifications Material Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure Capacitor motor Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Dielectric strength (with sensor) 50/60 Hz 1500 VAC 1 minute (between AC input terminal and frame) 50/60 Hz 1000 VAC 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger Sound pressure level (SPL) At 1 m away from the air inlet Operating voltage range Voltage of each model 10% Storage temperature -30 to +70C (Non-condensing) Sensor Sensor-Purpose lead wire Brown Black Yellow Mass 1100 g Specifications Standard Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V Hz W A A min m/min CFM Pa inchH O dB (A) C h 109-601 100 0.43/0.35 0.72/0.7 109-604 115 0.39/0.31 0.62/0.61 50/60 37.5/33 2850/3350 7.2/8.5 254.4/300.4 156.8/166.6 0.63/0.669 56/60 -30 to +60 25000/60C 109-602 200 0.23/0.18 0.36/0.35 109-603 230 0.21/0.16 0.32/0.31 with Sensor For sensor specifications, please refer to p. 550. Sensor specification differs depending on the fan s speed specification. For a 5 V sensor power supply (ITEM-20), please append-20 to the end of model number. E.g. 109-641-20 For a 12 V sensor power supply (ITEM-30), please append-30 to the end of model number. E.g. 109-641-30 Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V Hz W A A min m/min CFM Pa inchH O dB (A) C h 109-641 100 0.43/0.35 0.72/0.7 109-644 115 0.39/0.31 0.62/0.61 50/60 37.5/33 2850/3350 7.2/8.5 254.4/300.4 156.8/166.6 0.63/0.669 56/60 -10 to +60 25000/60C 109-642 200 0.23/0.18 0.36/0.35 109-643 230 0.21/0.16 0.32/0.31 Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan Voltage Low-speed sensor Plug cord* Finger guards Mounting screws ST1-109-601 109-601 100 V 489-1618-L10 109-619E ST1-109-604 109-604 115 V 489-1618-L10 109-619E ST1-109-602 109-602 200 V 489-1618-L10 109-619E ST1-109-603 109-603 230 V 489-1618-L10 109-619E ST1-109-641-20 109-641-20 (5 V) 489-1618-L10 109-619E 100 V ST1-109-641-30 109-641-30 (12 V) 489-1618-L10 109-619E M520 mm (4 screws) ST1-109-644-20 109-644-20 (5 V) 489-1618-L10 109-619E 115 V ST1-109-644-30 109-644-30 (12 V) 489-1618-L10 109-619E ST1-109-642-20 109-642-20 (5 V) 489-1618-L10 109-619E 200 V ST1-109-642-30 109-642-30 (12 V) 489-1618-L10 109-619E ST1-109-643-20 109-643-20 (5 V) 489-1618-L10 109-619E 230 V ST1-109-643-30 109-643-30 (12 V) 489-1618-L10 109-619E * PSE compatible. 509 AC Fan 160 mm sq. AC175 Airflow - Static Pressure Characteristics Standard with Sensor 109-601, 109-604, 109-602, 109-603 109-641, 109-644, 109-642, 109-643 2 (inch H O) (Pa) (inch H2O) (Pa) 0.8 200 0.8 200 60 Hz 100 V/115 V/200 V/230 V 150 0.6 60 Hz 100 V/115 V/200 V/230 V 0.6 150 50 Hz 100 V/115 V/200 V/230 V 0.4 100 0.4 100 50 Hz 100 V/115 V/200 V/230 V 0.2 50 0.2 50 0 0 0 0 3 3 1 2 3 4 5 6 7 8 9 (m /min) 1 2 3 4 5 6 7 8 9 (m /min) 0 50 100 150 200 250 300 350 (CFM) (CFM) 0 50 100 150 200 250 300 350 Airflow Airflow Dimensions (unit: mm) Standard +1 +1 160 0 51 0 138.50.3 8-5.5 28 max.28 (4) (4) Mounting hole M40.7, 5 mm deepM40.75 Earth ground tap AIRFLOW Airflow direction Rotating direction with Sensor +1 +1 51 0 160 0 8-5.5 (4) (4) 138.50.3 28 max. 28 Mounting hole M40.7, 5 mm deepM40.75 Earth ground tap AIRFLOW Sensor-purpose lead wire Length 300L 300L AWG28 AWG28 UL 1007 UL 1007 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 157 4-5.7 138.50.3 510 Static pressure +1 160 0 +1 160 0 138.50.3 138.50.3 138.50.3 157 Static pressure ROTATION ROTATION