AC Fan 80 80 25 mm San Ace 80 General Specifications Material Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor structure Shaded coil motor Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 1500 VAC, for 1 minute (between input terminal and frame) Insulation resistance 10 M or more with a 500 VDC megger Sound pressure level (SPL) At 1 m away from the air inlet Operating voltage range Voltage of each model 10% Storage temperature -30 to +70C (Non-condensing) Mass 270 g Specifications Rated voltage Frequency Input Current Locked rotor current Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V Hz W A A min m/min CFM Pa inchH O dB (A) C h 109S050 100 0.12/0.1 0.13/0.11 109S053 115 0.1 /0.08 0.11/0.09 2650/3100 0.63/0.76 22.3/26.9 27.5/38.3 0.11 /0.154 30/33 109S051 200 0.06/0.05 0.06/0.05 109S054 230 0.05/0.04 0.05/0.04 50/60 9/7 -30 to +60 25000/60C 109S030 100 0.12/0.1 0.13/0.11 109S033 115 0.1 /0.08 0.11/0.09 2350/2700 0.55/0.63 19.4/22.3 21.6/28.4 0.087/0.114 28/30 109S031 200 0.06/0.05 0.06/0.05 109S034 230 0.05/0.04 0.05/0.04 Set Models Fan, finger guard, plug cord, screws, etc. can be purchased in one package. For details, please refer to p. 594. Set items Order no. Fan Voltage Low-speed sensor Plug cord* Finger guards Mounting screws ST1-109S050 109S050 100 V 489-016-L10 109-049E ST1-109S053 109S053 115 V 489-016-L10 109-049E ST1-109S051 109S051 200 V 489-016-L10 109-049E ST1-109S054 109S054 230 V 489-016-L10 109-049E M4 40 mm (4 screws)** ST1-109S030 109S030 100 V 489-016-L10 109-049E ST1-109S033 109S033 115 V 489-016-L10 109-049E ST1-109S031 109S031 200 V 489-016-L10 109-049E ST1-109S034 109S034 230 V 489-016-L10 109-049E * PSE compatible. ** Though these are 2-hole or 3-hole frame mount types, 4 screws are included for extra. Airflow - Static Pressure Characteristics 109S050, 109S053, 109S051, 109S054 109S030, 109S033, 109S031, 109S034 2 2 (inch H O) (Pa) (inch H O) (Pa) 0.20 50 0.20 50 40 40 0.15 0.15 60 Hz 100 V/115 V/200 V/230 V 60 Hz 100 V/115 V/200 V/230 V 30 30 50 Hz 100 V/115 V/200 V/230 V 50 Hz 100 V/115 V/200 V/230 V 0.10 0.10 20 20 0.05 0.05 10 10 0 0 0 0 3 3 0.2 0.4 0.6 0.8 (m /min) 0.25 0.50 0.75 (m /min) 0 5 10 15 20 25 30 (CFM) 0 10 20 30 (CFM) Airflow Airflow 490 Static pressure Static pressure(unit: mm) Dimensions 26 max. 26 800.5 250.5 6-4.3 71.50.3 Mounting hole (3.5) (3.5) M40.7, 6 mm deep M40.76 Earth ground tap AIRFLOW Rotating direction Airflow direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side Outlet side 71.50.3 3-4.5 71.50.3 3-4.5 78 Wiring Diagram A C FAN Options page: p. 532 page: p. 539 Finger guards Resin finger guards Model no.: 109-049E, 109-049H, 109-049C Model no.: 109-1002G Resin filter kits page: p. 540 Plug cord page: pp. 542 to 543 Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), Model no.: 489-016-L10, 489-016-L21, 489-047-L10, 109-1002F30 (30PPI), 109-1002F40 (40PPI) 489-047-L21 491 78 89.5 800.5 71.50.3 AC power supply 71.50.3 78 71.50.3 AC Fan 80 mm sq. AC