DC Fan 80 80 25 mm San Ace 80 9S type Silent Fan Model 9S0812H401 is not TV certified. General Specifications Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black Yellow Mass 75 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append1 to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 9S0812H401 5.0 to 13.2 0.23 2.76 3400 1.12 39.5 52.15 0.2 31 9S0812F401 0.11 1.32 2800 0.93 32.8 35.5 0.143 24 12 5.0 to 13.8 9S0812M401 0.08 0.96 2500 0.83 29.3 27.5 0.11 22 -10 to +70 40000/60C 9S0812L401 6.0 to 13.8 0.05 0.6 2000 0.66 23.3 18.1 0.073 16 9S0824M401 0.06 1.44 2500 0.83 29.3 27.5 0.11 22 24 10 to 26.4 9S0824L401 0.04 0.96 2000 0.66 23.3 18.1 0.073 16 The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 577. Without sensor PWM control Airflow - Static Pressure Characteristics 9S0812H401 With pulse sensor 9S0812F401 With pulse sensor 9S0812M401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 2 (inch H O) (Pa) (inch H O) (Pa) (inch H2O) (Pa) 0.20 0.20 70 50 50 0.25 60 40 40 0.15 0.15 13.8 V 50 13.8 V 0.20 13.2 V 30 30 40 12 V 12 V 0.15 0.10 12 V 0.10 30 20 20 0.10 5 V 20 0.05 0.05 10 10 5 V 0.05 10 5 V 0 0 0 0 0 0 3 3 3 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0.2 0.4 0.6 0.8 1.0 1.2 (m /min) 0.2 0.4 0.6 0.8 1.0 (m /min) (m /min) (CFM) 0 10 20 30 40 50 0 5 10 15 20 25 30 35 40 (CFM) 0 5 10 15 20 25 30 35 (CFM) Airflow Airflow Airflow 121 Static pressure Static pressure Static pressure DC Fan 80 mm sq. DC Airflow - Static Pressure Characteristics 9S0812L401 With pulse sensor 9S0824M401 With pulse sensor 9S0824L401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.20 0.20 0.20 50 50 50 40 40 40 0.15 0.15 0.15 26.4 V 13.8 V 26.4 V 30 30 30 0.10 24 V 0.10 0.10 12 V 24 V 20 20 20 6 V 0.05 10 V 0.05 0.05 10 10 10 10 V 0 0 0 0 0 0 3 3 3 (m /min) (m /min) 0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0 (m /min) 0.2 0.4 0.6 0.8 1.0 0 5 10 15 20 25 30 35 (CFM) 0 5 10 15 20 25 30 35 (CFM) 0 5 10 15 20 25 30 35 (CFM) Airflow Airflow Airflow Dimensions (unit: mm) (With ribs) 250.5 4-4.30.3 (4) (4) Mounting hole Lead wire AWG24 UL 1007 +50 300 0 (10) 71.50.3 800.5 Airflow direction Rotating direction Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 4-4.5 71.50.3 78.5 Options Finger guards page: p. 532 Resin finger guards page: p. 539 Model no.: 109-049E, 109-049H, 109-049C Model no.: 109-1002G page: p. 540 Resin filter kits Model no.: 109-1002F13 (13PPI), 109-1002F20 (20PPI), 109-1002F30 (30PPI), 109-1002F40 (40PPI) 122 90 78.5 Static pressure 800.5 71.50.3 71.50.3 Static pressure Static pressure