DATASHEET Single-Stage Filters FN 2030 General Purpose EMI Filter with High Attenuation Performance Rated currents from 1 to 30 A Approvals High performance filter attenuation High differential-mode attenuation Optional medical versions (B type) Optional safety versions (A type) Optional overvoltage protection (Z type) Features and benefits FN 2030 filters are designed for easy and fast chassis Performance indicators mounting The FN 2030 filters are also available as B versions with no Y-capacitors for medical applications as well as A versions with low capacitance for safety critical applications with a requirement for low leakage currents All filters provide an exceptional conducted attenuation performance, based on chokes with high permeable core material and excellent thermal behavior The higher inductivity versus amperage offers increased attenuation performance with same form factor compared to FN 2010 and FN 2020 filter series Technical specifications All FN 2030 filters can be delivered with optional surge pulse protection. FN 2030 filters are also available as two- stage filters (FN 2090 series) for Operating voltage 110/250 VAC, 50/60 Hz very noisy environment Operating frequency dc to 400 Hz Various terminal options allow you to select the Rated currents 1 to 30 A 40C max. desired connection style High potential test voltage P > PE 2000 VAC for 2 sec (standard types) P > PE 2500 VAC for 2 sec (B types) P > N 1100 VDC for 2 sec Typical application Temperature range (operation and storage) -25C to +100C (25/100/21) Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Electrical and electronic equipment Flammability corresponding to UL 94 V-2 or better Consumer goods Surge pulse protection (optional) 2 kV, IEC 61000-4-5 Household equipment MTBF 40C/230 V (Mil-HB-217F) 2,200,000 hours (1 to 10 A types) Medical equipment 1,200,000 hours (12 to 30 A types) Electronic data processing equipment Office automation and datacom equipment Various noisy applications requiring high filter performance Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 2016 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40C (25C) 230 VAC/50 Hz L Cx Cy R connections A mA mH F nF k g FN 2030-1-.. (1.1) 0.34 20 0.22 2.2 1000 -06 -07 58 FN 2030-3-.. 3 (3.4) 0.52 14 0.33 3.3 1000 -06 -07 87 FN 2030-4-.. 4 (4.5) 0.52 14 0.33 3.3 1000 -06 -07 92 FN 2030-6-.. 6 (6.7) 0.73 8 0.47 4.7 680 -06 -07 100 FN 2030-8-.. 8 (8.9) 0.73 8 0.47 4.7 680 -06 -07 170 FN 2030-10-.. 10 (11.2) 0.73 8 0.47 4.7 680 -06 -07 196 FN 2030-12-.. 12 (13.4) 0.87 4 1.0 10 330 -06 -07 185 FN 2030-16-.. 16 (17.9) 0.87 4 1.0 10 330 -06 -07 225 FN 2030-20-.. 20 (22.4) 0.87 4 1.0 10 330 -06 -08 285 FN 2030-30-08 30 (33.5) 0.87 2 1.0 10 330 -08 326 FN 2030 A-1-.. 1 (1.1) 0.074 20 0.22 0.47 1000 -06 -07 58 FN 2030 A-3-.. 3 (3.4) 0.074 14 0.33 0.47 1000 -06 -07 87 FN 2030 A-4-.. 4 (4.5) 0.074 14 0.33 0.47 1000 -06 -07 92 FN 2030 A-6-.. 6 (6.7) 0.074 8 0.47 0.47 680 -06 -07 100 FN 2030 A-8-.. 8 (8.9) 0.074 8 0.47 0.47 680 -06 -07 170 FN 2030 A-10-.. 10 (11.2) 0.074 8 0.47 0.47 680 -06 -07 196 FN 2030 A-12-.. 12 (13.4) 0.074 4 1.0 0.47 330 -06 -07 185 FN 2030 A-16-.. 16 (17.9) 0.074 4 1.0 0.47 330 -06 -07 225 FN 2030 A-20-.. 20 (22.4) 0.074 4 1.0 0.47 330 -06 -08 285 FN 2030 A-30-08 30 (33.5) 0.074 2 1.0 0.47 330 -08 326 FN 2030 B-1-.. 1 (1.1) 0.002 20 0.22 1000 -06 -07 58 FN 2030 B-3-.. 3 (3.4) 0.002 14 0.33 1000 -06 -07 87 FN 2030 B-4-.. 4 (4.5) 0.002 14 0.33 1000 -06 -07 92 FN 2030 B-6-.. 6 (6.7) 0.002 8 0.47 680 -06 -07 100 FN 2030 B-8-.. 8 (8.9) 0.002 8 0.47 680 -06 -07 170 FN 2030 B-10-.. 10 (11.2) 0.002 8.45 0.47 680 -06 -07 196 FN 2030 B-12-.. 12 (13.4) 0.002 4 1.0 330 -06 -07 185 FN 2030 B-16-.. 16 (17.9) 0.002 4 1.0 330 -06 -07 225 FN 2030 B-20-.. 20 (22.4) 0.002 4 1.0 330 -06 -08 285 FN 2030 B-30-08 30 (33.5) 0.002 2 1.0 330 -08 326 * To compile a complete part number, please replace the -.. with the required I/O connection style. For surge pulse protection, please add Z (e.g. FN 2030Z-10-06, FN 2030BZ-20-08). ** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation Per CISPR 17 A=50 /50 sym B=50 /50 asym C=0.1 /100 sym D=100 /0.1 sym 1 to 4 A types 6 to 10 A types 12 to 20 A types 30 A types