DATASHEET Two-Stage Filters FN 2060 Multi-stage General Purpose AC/DC EMI Filter Rated currents from 1 to 30 A Approvals High differential and common-mode attenuation Optional medical versions (B type) Optional safety versions (A type) Features and benefits Performance indicators FN 2060 two-stage filters are designed for easy and fast chassis mounting FN 2060 filters are also available as B versions without Y-capacitors for medical applications as well as A version with low capacitance for safety critical applications with necessity for low leakage currents All filters provide a high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior FN 2060 two-stage filters are designed for noisy applications requiering good differential and common-mode attenuation FN 2060 filters are also available as single-stage Technical specifications filters (FN 2010 series) Various terminal options allow you to select the 250 VAC, 50/60 Hz 250 VDC Rated voltage* desired connection style Operating frequency DC to 400 Hz Rated currents 1 to 30 A 40C max. Typical applications High potential test voltage P > PE 2000 VAC for 2 sec P > PE 2500 VAC for 2 sec (B types) Electrical and electronic equipment P > N 1100 VDC for 2 sec Consumer goods -25C to +100C (25/100/21) Temperature range (operation and storage) Certified to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to Household equipment AC and DC applications) Building automation UL 94 V-2 or better Flammability corresponding to Industrial applications Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Machinery MTBF 40C/230 V (Mil-HB-217F) 1,650,000 hours (B types) Medical equipment 950,000 hours Electronic data processing equipment *maximum RMS operating voltage at rated frequency or the maximum DC operating voltage Office automation and datacom equipment Various noisy applications requiering good filter performance Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 2017 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40C (25C) 250 VAC/50 Hz L Cx Cy R connections ( 120 VAC/60 Hz) A mA mH F nF k g FN 2060-1-.. 1 (1.2) 0.66 (0.38) 12 0.22 4.7 1000 -06 -07 120 FN 2060-3-.. 3 (3.5) 0.66 (0.38) 2.5 0.22 4.7 1000 -06 -07 120 FN 2060-6-.. 6 (6.9) 0.66 (0.38) 0.97 0.22 4.7 1000 -06 -07 120 FN 2060-10-.. 10 (11.5) 0.66 (0.38) 0.8 0.47 4.7 470 -06 -07 190 FN 2060-12-.. 12 (13.8) 0.66 (0.38) 0.58 0.47 4.7 470 -06 -07 190 FN 2060-16-.. 16 (18.4) 0.66 (0.38) 0.65 0.33 4.7 1000 -06 -07 -08 260 FN 2060-20-.. 20 (23) 0.66 (0.38) 0.6 1 4.7 220 -06 -08 480 FN 2060-30-08 30 (34.5) 0.79 (0.45) 0.6 1 10 220 -08 950 FN 2060A-1-.. 1 (1.2) 0.07 (0.04) 12 0.22 0.47 1000 -06 -07 120 FN 2060A-3-.. 3 (3.5) 0.07 (0.04) 2.5 0.22 0.47 1000 -06 -07 120 FN 2060A-6-.. 6 (6.9) 0.07 (0.04) 0.97 0.22 0.47 1000 -06 -07 120 FN 2060A-10-.. 10 (11.5) 0.07 (0.04) 0.8 0.47 0.47 470 -06 -07 190 FN 2060A-12-.. 12 (13.8) 0.07 (0.04) 0.58 0.47 0.47 470 -06 -07 190 FN 2060A-16-.. 16 (18.4) 0.07 (0.04) 0.65 0.33 0.47 1000 -06 -07 -08 260 FN 2060A-20-.. 20 (23) 0.07 (0.04) 0.6 1 0.47 220 -06 -08 480 FN 2060A-30-08 30 (34.5) 0.07 (0.04) 0.6 1 0.47 220 -08 950 FN 2060B-1-.. 1 (1.2) 0.00 12 0.22 1000 -06 -07 120 FN 2060B-3-.. 3 (3.5) 0.00 2.5 0.22 1000 -06 -07 120 FN 2060B-6-.. 6 (6.9) 0.00 0.97 0.22 1000 -06 -07 120 FN 2060B-10-.. 10 (11.5) 0.00 0.8 0.47 470 -06 -07 190 FN 2060B-12-.. 12 (13.8) 0.00 0.58 0.47 470 -06 -07 190 FN 2060B-16-.. 16 (18.4) 0.00 0.65 0.33 1000 -06 -07 -08 260 FN 2060B-20-.. 20 (23) 0.00 0.6 1 220 -06 -08 480 FN 2060B-30-08 30 (34.5) 0.00 0.6 1 220 -08 950 ** To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2060-30-08, FN 2060B-10-06). ** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Leakage current for DC application is 0 mA Typical filter attenuation dPer CISPR 17 A=50 /50 sym B=50 /50 asym C=0.1 /100 sym D=100 /0.1 sym 1 A types 3 to 12 A types 16 A types 20 and 30 A types