DATASHEET Two-Stage Filters FN 2070 Multi-stage Performance AC/DC EMI Filter Rated currents from 1 to 36 A Approvals & Compliances High differential and common-mode attenuation High frequency attenuation Optional medical versions (B type) Optional safety versions (A type) Features and benefits FN 2070 two-stage filters are designed for easy and fast chassis mounting FN 2070 B versions without capacitors to earth comply to 1MOP for ME (medical equipment) acc. Technical specifications IEC 60601-1 Fn 2070 A version with low capacitance to earth for 250 VAC, 50/60 Hz 250 VDC Rated voltage* safety critical applications with necessity for low Operating frequency DC to 400 Hz leakage currents Rated currents 1 to 36 A 40C max. All filters provide a high conducted attenuation High potential test voltage P > PE 2000 VAC for 2 sec performance, based on chokes with high saturation P > PE 2500 VAC for 2 sec (B types) resistance and excellent thermal behavior P > N 1100 VDC for 2 sec Temperature range (operation and storage) -25C to +100C (25/100/21)** FN 2070 two-stage filters are designed for high frequency attenuation UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to Certified to AC and DC applications) FN 2070 filters are also available as single- stage Flammability corresponding to Terminal plastic for -06/-08 version: UL 94 V-0 filters (FN 2030 series) Laces for -07 version: UL 94 VW-1 FN 2070 filters are also available with differential Grommet for -07 version: UL 94V-0 mode choke (FN 2080 series) Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Various terminal options allow you to select the Overvoltage category II acc. IEC 60664-1 desired connection style Pollution degree 2 acc. IEC 60664-1 Altitude 2000m (above derating applies)** Typical applications 1,550,000 hours MTBF 40C/230 V (Mil-HB-217F) 1,600,000 hours (B types) Electrical and electronic equipment Consumer goods * maximum RMS operating voltage at rated frequency or the maximum DC operating voltage ** for dedicated requests exceeding this specification (e.g. -40 C or higher altitude) please contact your local Household equipment Schaffner Sales office Building automation Industrial applications Machinery Medical equipment Electronic data processing equipment Office automation and datacom equipment Various noisy applications requiering good filter performance Single Phase Motor Drives Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 02 Feb 2021 Filter selection table Filter* Buy Rated current Leakage current** Power Loss Inductance*** Capacitance*** Resistance*** Input/Output Weight 40C (25C) 250 VAC/50 Hz 25C/DC L Cx Cy R connections ( 120 VAC/60 Hz) A mA W mH F nF k g FN2070-1-.. 1 (1.2) 0.66 (0.38) 2.4 22 0.33 4.7 1000 -06 -07 190 FN2070-3-.. 3 (3.5) 0.66 (0.38) 2.2 9.8 0.47 4.7 470 -06 -07 250 FN2070-6-.. 6 (6.9) 0.66 (0.38) 3.2 7.8 1 4.7 220 -06 -07 450 FN2070-10-.. 10 (11.5) 0.66 (0.38) 9.1 4.5 1 4.7 220 -06 -07 -08 670 FN2070-12-.. 12 (13.8) 0.66 (0.38) 13.1 3.25 1 4.7 220 -06 -07 -08 670 FN2070-16-.. 16 (18.4) 0.66 (0.38) 9.6 2.8 1 4.7 220 -06 -07 -08 1000 FN2070-25-08 25 (28.8) 0.66 (0.38) 11.6 2 2.2 4.7 220 -08 760 FN2070-36-08 36 (41.4) 0.66 (0.38) 13.1 1.23 2.2 4.7 220 -08 790 FN2070A-1-.. 1 (1.2) 0.07 (0.04) 2.4 22 0.33 0.47 1000 -06 -07 190 FN2070A-3-.. 3 (3.5) 0.07 (0.04) 2.2 9.8 0.47 0.47 470 -06 -07 250 FN2070A-6-.. 6 (6.9) 0.07 (0.04) 3.2 7.8 1 0.47 220 -06 -07 450 FN2070A-10-.. 10 (11.5) 0.07 (0.04) 9.1 4.5 1 0.47 220 -06 -07 -08 670 FN2070A-12-.. 12 (13.8) 0.07 (0.04) 13.1 3.25 1 0.47 220 -06 -07 -08 670 FN2070A-16-.. 16 (18.4) 0.07 (0.04) 9.6 2.8 1 0.47 220 -06 -07 -08 1000 FN2070A-25-08 25 (28.8) 0.07 (0.04) 11.6 2 2.2 0.47 220 -08 760 FN2070A-36-08 36 (41.4) 0.07 (0.04) 13.1 1.23 2.2 0.47 220 -08 790 FN2070B-1-.. 1 (1.2) 0.00 2.4 22 0.33 1000 -06 -07 190 FN2070B-3-.. 3 (3.5) 0.00 2.2 9.8 0.47 470 -06 -07 250 FN2070B-6-.. 6 (6.9) 0.00 3.2 7.8 1 220 -06 -07 450 FN2070B-10-.. 10 (11.5) 0.00 9.1 4.5 1 220 -06 -07 -08 670 FN2070B-12-.. 12 (13.8) 0.00 13.1 3.25 1 220 -06 -07 -08 670 FN2070B-16-.. 16 (18.4) 0.00 9.6 2.8 1 220 -06 -07 -08 1000 FN2070B-25-08 25 (28.8) 0.00 11.6 2 2.2 220 -08 760 FN2070B-36-08 36 (41.4) 0.00 13.1 1.23 2.2 220 -08 790 Enhanced performance FN2070M-1-06 1 (1.2) 3.69 (2.13) 2.4 22 0.33 47 1000 -06 170 FN2070M-3-06 3 (3.5) 3.69 (2.13) 2.2 9.8 0.47 47 470 -06 250 FN2070M-6-06 6 (6.9) 3.69 (2.13) 3.2 7.8 1 47 220 -06 450 FN2070M-10-.. 10 (11.5) 3.69 (2.13) 9.1 4.5 1 47 220 -06 -08 670 FN2070M-12-.. 12 (13.8) 3.69 (2.13) 13.1 3.25 1 47 220 -06 -08 670 FN2070M-16-.. 16 (18.4) 3.69 (2.13) 9.6 2.8 1 47 220 -06 -08 1000 FN2070M-25-08 25 (28.8) 3.69 (2.13) 11.6 2 2.2 47 220 -08 750 FN2070L-36-08 36 (41.4) 2.59 (1.49) 13.1 1.23 2.2 33 220 -08 790 * To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2070-25-08, FN 2070B-10-06). ** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. *** Tolerances apply: Inductance: -30/+50%, Capacitance: 20%, Resistance: 10%