DATASHEET Two-Stage Filters FN 2080 Multi-stage High Performance AC/DC EMI Filter Rated currents from 1 to 16 A Approvals High differential and common-mode attenuation Good low frequency attenuation Optional medical versions (B type) Optional safety versions (A type) Features and benefits FN 2080 two-stage filters are designed for easy and Performance indicators fast chassis mounting FN 2080 filters are also available as B versions without Y-capacitors for medical applications as well as A version with low capacitance for safety critical applications with necessity for low leakage currents All filters provide a high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior FN 2080 two-stage filters are designed with good low frequency attenuation FN 2080 filters are also available as single- stage filters FN 2080 filters are also available with two common Technical specifications mode choke configuration (FN 2070 series) Various terminal options allow you to select the Rated voltage* 250 VAC, 50/60 Hz 250 VDC desired connection style Operating frequency DC to 400 Hz 1 to 16 A 40C max. Rated currents High potential test voltage P > PE 2000 VAC for 2 sec P > PE 2500 VAC for 2 sec (B types) Typical applications P > N 1100 VDC for 2 sec Electrical and electronic equipment Temperature range (operation and storage) -25C to +100C (25/100/21) Consumer goods Certified to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to AC and DC applications) Household equipment Flammability corresponding to UL 94 V-2 or better Building automation Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Industrial applications 1,650,000 hours MTBF 40C/230 V (Mil-HB-217F) Machinery 1,700,000 hours (B types) Medical equipment *maximum RMS operating voltage at rated frequency or the maximum DC operating voltage Electronic data processing equipment Office automation and datacom equipment Various noisy applications requiering good filter performance Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 11 Oct 2018 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40C (25C) 250 VAC/50 Hz L L1 Cx Cy R connections ( 120 VAC/60 Hz ) A mA mH H F nF k g FN 2080-1-.. 1 (1.2) 0.66 (0.38) 22 490 0.33 4.7 1000 -06 -07 200 FN 2080-3-.. 3 (3.5) 0.66 (0.38) 9.8 160 0.47 4.7 470 -06 -07 270 FN 2080-6-.. 6 (6.9) 0.66 (0.38) 7.8 110 1 4.7 220 -06 -07 470 FN 2080-10-.. 10 (11.5) 0.66 (0.38) 4.5 60 1 4.7 220 -06 -07 750 FN 2080-12-.. 12 (13.8) 0.66 (0.38) 3.25 50 1 4.7 220 -06 -07 750 FN 2080-16-.. 16 (18.4) 0.66 (0.38) 2.8 43 1 4.7 220 -06 -07 -08 1020 FN 2080A-1-.. 1 (1.2) 0.07 (0.04) 22 490 0.33 0.47 1000 -06 -07 200 FN 2080A-3-.. 3 (3.5) 0.07 (0.04) 9.8 160 0.47 0.47 470 -06 -07 270 FN 2080A-6-.. 6 (6.9) 0.07 (0.04) 7.8 110 1 0.47 220 -06 -07 470 FN 2080A-10-.. 10 (11.5) 0.07 (0.04) 4.5 60 1 0.47 220 -06 -07 750 FN 2080A-12-.. 12 (13.8) 0.07 (0.04) 3.25 50 1 0.47 220 -06 -07 750 FN 2080A-16-.. 16 (18.4) 0.07 (0.04) 2.8 43 1 0.47 220 -06 -07 -08 1020 FN 2080B-1-.. 1 (1.2) 0.00 22 490 0.33 1000 -06 -07 200 FN 2080B-3-.. 3 (3.5) 0.00 9.8 160 0.47 470 -06 -07 270 FN 2080B-6-.. 6 (6.9) 0.00 7.8 110 1 220 -06 -07 470 FN 2080B-10-.. 10 (11.5) 0.00 4.5 60 1 220 -06 -07 750 FN 2080B-12-.. 12 (13.8) 0.00 3.25 50 1 220 -06 -07 750 FN 2080B-16-.. 16 (18.4) 0.00 2.8 43 1 220 -06 -07 -08 1020 * To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2080-16-08, FN 2080B-10-06). ** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Leakage current for DC application is 0 mA Typical filter attenuation Per CISPR 17 A=50 /50 sym B=50 /50 asym C=0.1 /100 sym D=100 /0.1 sym 1 to 6 A types 10 and 12 A types 16 A types