DATASHEET 3-Phase Filters FN 3268 EMC/EMI Filter for Installations with Residual Current Device (RCD) Full functionality with RCDs according to IEC Approvals 61008 and new VDE 0664-110* Compatible with 30 mA RCDs up to 30 m motor cable for electric shock protection according to IEC 61008 Compatible with 300 mA RCDs up to 100 m motor cable for fire protection according to IEC 60364-4-42 (VDE 0100-482) Features and benefits Innovative low-leakage current filter with same smallest dimensions as FN 3258 Performance indicators Significant reduction of leakage and ground currents caused by long motor cables Prevents unwanted fault shut-downs from RCDs in machines and process automation equipment Patented filter design avoiding early saturation and ringing effects Excellent attenuation compliant with: C1 limits EN 61800-3 with 30 meter motor cable and 30 mA RCD (electric shock protection)** C2 limits EN 61800-3 with 100 meter motor cable and 300 mA RCD (fire protection) Typical applications Technical specifications Three-phase variable speed drives (VSD), servo Maximum continuous operating voltage 3x 520/300 VAC drives, and inverters Operating frequency DC to 60 Hz Machinery and process automation equipment Rated currents 7 to 180 A 50C Building automation, HVAC equipment, pumps, High potential test voltage P > E 2750 VDC for 2 sec ventilation, and elevators P > P 2250 VDC for 2 sec Conveyors, handling and storage systems, and Protection category IP 20 cranes Overload capability 4x rated current at switch on, Machine tools, wood working machines, and 1.5x rated current for 1 minute, once per hour printing machines Temperature range (operation and storage) -25C to +100C (25/100/21) Flammability corresponding to UL 94 V-2 or better UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Design corresponding to Typical electrical schematic MTBF 50C/400 V (Mil-HB-217F) >300,000 hours ** If supply voltage is contaminated with harmonics according to IEC 61000-2-4, class 2, where odd-numbered multiplies of three are limited to 30%. ** Filter types 7 A up to 42 A: C1, 30 m, 30 mA 55 A: C2, 30 m, 30 mA 75 A up to 180 A: C2, 100 m, 300 mA2 EMC/EMI Products Schaffner Group Datasheets 11 Oct 2018 Filter selection table Filter Rated current Typical drive Leakage current Power loss Input/Output Weight 50C (40C) power rating* 520 VAC/50 Hz 25C/50 Hz connections A kW mA ** W kg FN 3268-7-44 7 (7.7) 4 2.5 4.5 -44 0.5 FN 3268-16-44 16 (17.5) 7.5 2.6 6.1 -44 0.8 FN 3268-30-33 30 (32.9) 18.5 2.6 13.5 -33 1.2 FN 3268-42-33 42 (46.0) 22 2.6 17.4 -33 1.4 FN 3268-55-34 55 (60.2) 37 2.6 18.1 -34 2.2 FN 3268-75-34 75 (82.2) 45 10.8 25.3 -34 2.9 FN 3268-100-35 100 (109.5) 55 9.6 30.0 -35 4.1 FN 3268-130-35 130 (142.4) 75 14.2 38.0 -35 4.6 FN 3268-180-40 180 (197.1) 110 17.4 48.6 -40 6.0 * Calculated at rated current, 440 VAC and cos phi=0.8. The exact value depends upon the efficiency of the drive, the motor and the entire application. ** Standardized calculated leakage current acc. IEC60939 under normal operating conditions. Typical filter attenuation Per CISPR 17 A=50 /50 sym B=50 /50 asym C=0.1 /100 sym D=100 /0.1 sym 7 to 42 A types 55 to 100 A types 130 and 180 A types Installation EMC/EMI filter FN 3268 Motor cable length Filter types from 7 to 55 A are designed to be Motor cable length should not exceed 30 meters for compatible with 30 mA RCDs according to IEC 7 up to 55 A filter types to fulfill class C1 of 61008 and new VDE 0664-110 standards. Filters recommended standard EN 61800-3. For 75 up to from 75 up to 180 A are designed to be 180 A filters, cable length should not exceed 100 compatible with 300 mA RCDs. Install the filter as meters to fulfill class C2. close as possible at line side of the motor drive. Internal EMC/EMI components Regarding correct EMC installation, please refer to Please disconnect all internal Y-capacitors (internal the EMC installation guide in the manual from EMC/EMI filters) in the motor drive, because these motor drive supplier. capacitors cause additional leakage currents. Motor drive Harmonics on line voltage Please set the PWM pulse pattern of the variable High voltage harmonics can create additional speed motor drive fixed to 4 kHz. Other pulse system leakage currents. FN 3268 filters are tested patterns cause higher leakage currents. Filter under following conditions: Supply voltage is designs with other pulse pattern than 4 kHz are contaminated with harmonics according to IEC possible upon request. 61000-2-4, class 2, where odd-numbered multiplies of three are limited to 30%. Typical installation with RCD, EMC/EMI filter and motor drive system RCD Please note that for electrical devices with 6-pulse rectifiers at line input, like three-phase motor drives, a RCD type B or B+ is required. RCD with time delay are needed to prevent unwanted fault trip at switch on or voltage spikes. These RCD types B with time delay have often an added letter S or K, please ask the supplier for correct type. Caution: Please validate system with chosen RCD to guarantee functionality.