300 Series Power Relays/Two Pole 30 Amp Rating (DC and AC) Solderable Quick-Connect 2mm contact gaps and 8mm Terminals creepage and clearance meets international requirements Wide spacing between stationary contacts for fully booted Q.C. terminals A Variety of Covers for custom installations Square Base Optional Blowout Magnet for UL Recognized Improved dielectric strength between contacts File No. E43641 high voltage DC switching allows for 4000Vrms between mutually isolated conductive elements and frame General Specifications (UL 508) Contact Characteristics Units Standard SPST, SPDT, SPST-NO-DM Number and type of Contacts DPST, DPDT Contact materials Silver Alloy Silver Alloy Thermal (Carrying) Current A 30 30 Maximum Switching Voltage V 600V 600V Switching current voltage ~ Resistive 30A 300V 50/60Hz 30A 300V 50/60Hz Resistive 30A 28V 30A 28V HP 2 208-600 VAC 2 208-600 VAC HP 1 120 VAC 1 120 VAC Pilot Duty 5.5 A 120 VAC 5.5 A 120 VAC Current rating with magnetic blowout A 3 150V (69 Suffix) 10 150V (69 Suffix) Minimum Switching Requirement mA 500 12 VAC/VDC 500 12 VAC/VDC Minimum Coil Characteristics Voltage Range ~ V 6.240 6.240 V 6.125 6.125 Operating Range 85% to 110% 85% to 110% ~ % of Nominal 80% to 110% 80% to 110% Average consumption ~ VA 3.4 3.4 W 1.5 1.5 Drop-out voltage threshold 30% 30% ~ 10% 10% Performance Characteristics Electrical Life (UL 508) (Resistive) 30,000 30,000 Mechanical Life Operations Rated Current 5,000,000 5,000,000 Operating time (response time) Unpowered ms 20 20 ~ Dielectric V 2500 2500 Between coil and contact ~ V 4000 4000 Between poles V 2500 2500 ~ Between contacts Environment Product certifications UL, CSA UL, CSA Ambient air temperature Standard version C -40+85 -40+85 around the device Storage C -40+55 -40+55 Weight Operation grams 85 85 Part Number Builder 300 XBX Series Configuration DC Switching Option 300 = Standard XAX = SPDT 69 = Magnetic Blowouts near contacts F300 = Class F Coil BXX = DPST-NO XBX = DPDT XXB = DPST-NC HXX = SPST-NO-DM 6/16 Magnecraft Solution Guide 105A Magnecraft Solution Guide 105A SECTION 6www.magnecraft.com 847-441-2540 Available DIN rail mountable cover 300XBXC1 300XBXC4 Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED Nominal Input Voltage Coil Resistance (OHMS) Part Number Contact Configuration 220/240 VAC, 50/60 Hz 5400 300XBXC1-240A DPDT 110/120 VAC, 50/60 Hz 1270 300XBXC1-120A DPDT 24 VAC, 50/60 Hz 54 300XBXC1-24A DPDT 12 VAC, 50/60 Hz 13.5 300XBXC1-12A DPDT 110/125 VDC 6300 300XBXC1-110D DPDT 24 VDC 300 300XBXC1-24D DPDT 12 VDC 75 300XBXC1-12D DPDT 110/125 VDC 6300 300XBX69C1-110D DPDT 24 VDC 300 300XBX69C4-24D DPDT 12 VDC 75 300XBX69C1-12D DPDT WIRING DIAGRAM (BOTTOM VIEW) WIRING DIAGRAMS 1 2 1 2 1 2 3 4 3 4 3 4 3 4 5 6 5 6 5 6 5 6 A LED B A B A B A B XHX SPDT-N.C.-N.O. BXX DPST-N.O. XBX DPDT XBX DPDT (DB-DM) OBSERVE POLARITY ON DC COILS WIRING OF DIODE WIRING OF DIODE (SUFFIX OPTION) (SUFFIXV2 OPTION) 2 1 3 4 + + A B A B A B A BV2 COIL CONSTRUCTION COIL CONSTRUCTION XXH SPST-N.C.-DB HXX SPST-N.O.-DM DIODE FORV & V2 CONSTRUCTION DIODE 1N4007 OR 1N4005 C1 -12 D Cover Options* Coil Voltage Current Type C = Clear polycarbonate cover (To be used with PC Terminals) M = Manual Operator Coil Voltage A = AC C1 = Side flange mount cover L = Lamp across contacts D = DC C2 = Cover with anti=rotation tabs and thread mounting hole in frame T = Printed wiring terminals C3 = Top flanged cover C4 = Top DIN mount cover *Multiple Codes May be Used 6/17 Magnecraft Solution Guide 105A Magnecraft Solution Guide 105A SECTION 6