12/4/2017 Page 1 of 3 Schneider Electric Relays 200 N. Martingale Rd., Suite 1000 Schaumburg, IL 60173 Phone: 847-441-2540 Fax: 847-881-0741 E-Mail: relays schneider-electric.com Web site: www.serelays.com ITEM 781XAXRC-120A, 781 ICE CUBE RELAYS / SPDT, 15 AMP RATING SPECIFICATIONS COIL CHARACTERISTICS PERFORMANCE CHARACTERISTICS ENVIRONMENT PRODUCT CERTIFICATIONS Specifications Check Inventory Check Distributor Inventory Status Standard Legacy Part No. 781XAXC-120A Terminal Style Plug-in Contact Configuration SPDT Thermal (Carrying) Current 15 A Coil Resistance (Ohms) 4430 Ohm Load Type Standard Contact Materials Silver Alloy with Gold Flash IEC: 250 VAC Maximum Switching Voltages UL: 300 VAC IEC: 15 A at 150 VAC 50/60 Hz Switching Current at Voltage (AC, Resistive) UL: 15 A at 277 VAC 50/60 Hz12/4/2017 Page 2 of 3 IEC: 15 A at 28 VDC Switching Current at Voltage (DC, Resistive) UL: 15A at 28 VDC 1 at 277 VAC hp Switching Current at Voltage (HP) 1/2 at 120 VAC hp Pilot Duty B300 Minimum Switching Requirement 10 mA at 17 VDC Cover Options Plain Cover Features Mechanical flag indicator Coil Characteristics Coil Voltage 120 VAC 50/60 Hz Operating Range - % of Nominal (AC) 85 to 110 % Operating Range - % of Nominal (DC) 80 to 110 % Average Consumption (AC / VA) 1.60 VA Drop-out Voltage Threshold (AC) 15 % Drop-out Voltage Threshold (DC) 10 % Performance Characteristics Electrical Life (UL508), Operations at Rated 100000 Current (Resistive) Mechanical Life, Unpowered 10000000 Operating Time (Response Time) 20 ms Dielectric Strength - Between Coil and 2000 V(rms) Contact (AC) Dielectric Strength - Between Poles (AC) 2000 V(rms) Environment Vibration Resistance - Operational 3 g-n at 35-150 Hz Shock Resistance 15 g-n Degree of Protection IP 40 26 g Weight 0.92 oz