Description Magnecraft General Purpose Relays 792 Control Series DPDT 12 A 4PDT 6 A and 3 A Description The 792 Plug-in Control relays offer clear or full-feature covers with multiple mounting options and accessories 4PDT models save valuable space while adding increased UL listed when used with proper Magnecraft sockets functionality . Feature Benefit 12 A / 6 A / 3 A switching Ideal for various automation panels and controls current Clear or full-feature Full-feature covers include LED indicator and locking test button cover options to facilitate maintenance and expedite commissioning DPDT and 4PDT Simultaneously control 2 or 4 separate circuits contact options Socket mount option Simplifies installation and maintenance while also allowing the use of protection modules, hold-down clips and other accessories Gold-flashed contacts Reduces contact oxidation and increases shelf life 792 Clear Cover 792 Full-Feature Cover Mechanical flag indicator Standard feature that displays relay status during testing or operation without having to power the relay Contact Contact Nominal Coil Coil Part Number: Part Number: Part Number: Contacts Rating Configuration Voltage Resistance () Clear Cover Clear Cover with LED Full-Feature Cover 12 Vac 44 792XDX3C-12A 792XDX3CL-12A 792XDX3M4L-12A 24 Vac 177 792XDX3C-24A 792XDX3CL-24A 792XDX3M4L-24A 48 Vac 708 792XDX3C-48A 792XDX3CL-48A 792XDX3M4L-48A 120 Vac 3630 792XDX3C-120A 792XDX3CL-120A 792XDX3M4L-120A Low Level 3 A 4PDT 240 Vac 17720 792XDX3C-240A 792XDX3CL-240A 792XDX3M4L-240A Bifurcated 12 Vdc 160 792XDX3C-12D 792XDX3CL-12D 792XDX3M4L-12D 24 Vdc 640 792XDX3C-24D 792XDX3CL-24D 792XDX3M4L-24D 48 Vdc 2560 792XDX3C-48D 792XDX3CL-48D 792XDX3M4L-48D 110 Vdc 13440 792XDX3C-110D 792XDX3CL-110D 792XDX3M4L-110D 12 Vac 44 792XBXC-12A 792XBXM4L-12A 24 Vac 177 792XBXC-24A 792XBXM4L-24A 48 Vac 708 792XBXC-48A 792XBXM4L-48A 120 Vac 3630 792XBXC-120A 792XBXM4L-120A 12 A DPDT 240 Vac 17720 792XBXC-240A 792XBXM4L-240A 12 Vdc 160 792XBXC-12D 792XBXM4L-12D 24 Vdc 640 792XBXC-24D 792XBXM4L-24D 48 Vdc 2560 792XBXC-48D 792XBXM4L-48D 110 Vdc 13440 792XBXC-110D 792XBXM4L-110D Standard 12 Vac 44 792XDXC-12A 792XDXCL-12A 792XDXM4L-12A 24 Vac 177 792XDXC-24A 792XDXCL-24A 792XDXM4L-24A 48 Vac 708 792XDXC-48A 792XDXCL-48A 792XDXM4L-48A 120 Vac 3630 792XDXC-120A 792XDXCL-120A 792XDXM4L-120A 6 A 4PDT 240 Vac 17720 792XDXC-240A 792XDXCL-240A 792XDXM4L-240A 12 Vdc 160 792XDXC-12D 792XDXCL-12D 792XDXM4L-12D 24 Vdc 640 792XDXC-24D 792XDXCL-24D 792XDXM4L-24D 48 Vdc 2560 792XDXC-48D 792XDXCL-48D 792XDXM4L-48D 110 Vdc 13440 792XDXC-110D 792XDXCL-110D 792XDXM4L-110D Part Number Explanation Series: Coil Voltages: 792 = 792 Series 12240A = 12240 VAC Control Relay Cover Options: 12110D = 12110 VDC Contact Conguration: C = Clear Cover XBX = DPDT CL = Clear Cover and LED M4L = Locking Push Button XDX = 4PDT Contact Code: and LED None = Standard 612 A *Please contact Customer Service Silver Alloy Contacts for more information (847-441-2540). 3 = 3 A Bifurcated Contacts 4Specifications Magnecraft General Purpose Relays 792 Control Series DPDT 12 A 4PDT 6 A and 3 A Specifications Part Number 792XBX Contact Characteristics Terminal Style Blade Contact Material Silver Alloy Contact Configuration DPDT Maximum Switching Current 12 A Maximum Switching Voltage IEC: 250 Vac / 28 Vdc UL/CSA: 300 Vac / 30 Vdc Rated Operational Current NO: 12 A at 250 Vac, NC: 6 A at 250 Vac (Conforming to IEC AC-1 and DC-1) NO: 12 A at 28 Vdc, NC: 6 A at 28 Vdc Rated Operational Current Resistive: 12 A at 277 Vac,100k cycles (Conforming to UL) Resistive: 12 A at 120 Vac, 200k cycles Resistive: 12 A at 30 Vdc,100k cycles Motor: 1/2 HP at 120 Vac, 6k cycles Motor: 1 HP at 277 Vac, 6k cycles B300 PILOT DUTY, 6k cycles Minimum Switching Requirement 10 mA at 17 Vdc Coil Characteristics Maximum Operating Voltage 110% (AC / DC) Maximum Pickup Voltage 80% (AC) 80% (DC) Drop-out Voltage Threshold 15% (AC) 10% (DC) Average Consumption 091 . 2 V . A (AC) 0 .81 .1 W (DC) General Characteristics Electrical Life at Rated Load 200,000 operations (where stated) Mechanical Life (Unpowered) 10,000,000 operations Operating Time 25 ms max . at 80% rated coil voltage 20 ms max . at 100% rated coil voltage Release time 20 ms max . (DC) 35 ms max . (AC) Impulse Withstand Voltage 4 kV (12 / 50 . ms) Dielectric Strength - Between Coil and 2000 V(rms) Contact (AC) Dielectric Strength - Between Poles (AC) 2000 V(rms) Dielectric Strength - Between Contacts (AC) 1300 V(rms) Ambient Air Temperature around the Device -40 to +85 C (-40 to +185 F) - Storage Ambient Air Temperature around the Device -40 to +55 C (-40 to +131 F) - Operation Vibration Resistance - In Operation 3 g-n at 35150 Hz Vibration Resistance - Not Operating 5 g-n at 35150 Hz Shock Resistance - In Operation 10 g-n Shock Resistance - Not Operating 30 g-n Degree of Protection (Housing Only) IP 40 Weight 37 g (131 oz) . Agency Approvals UL with socket, UR (E164862), CE, CSA (225619), RoHS Note: Actual product performance may vary depending on application and environmental conditions. 5