Product data sheet
9012GDW4
Characteristics
pressure switch 9012G - fixed scale - 1
threshold - 1.5 to 75 psig
Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Range of product 9012G
Pressure sensor type Electromechanical pressure switch
Pressure sensor name 9012G
Pressure sensor size 75 psi
Maximum pressure 240 psi
Contacts type and com- NC-NO, SPDT-DB, Form Z, snap action, silver nickel
position contacts
Controlled fluid Air
Hydraulic oil (-40...250 F)
Non-corrosive liquids
Non-corrosive gas
Fluid connection type 0.25 inch 18 NPTF conforming to UL 508
Pressure switch type of Detection of 1 single threshold
operation
Scale type Fixed
Local display Without
Complementary
Range on decreasing pressure 1.5...75 psi
Approx fix differential at mid range 3 psi +/- 2.5 % full scale
Cable entry 0.5 inch NPT conduit entrance
Terminal block type 4 screw terminals
Electrical connection Screw-clamp terminals, AWG 22...AWG 12
Electrical circuit type Control circuit
Local signalling Without
[In] rated current 3 A (Ue = 240 V AC) contact code: A600 conforming to NEMA rating designation
6 A (Ue = 120 V AC) contact code: A600 conforming to NEMA rating designation
0.27 A (Ue = 250 V DC) contact code: R300 conforming to NEMA rating designa-
tion
0.22 A (Ue = 125 V DC) contact code: R300 conforming to NEMA rating designa-
tion
Setting Internal
Enclosure material Die cast aluminium alloy 380
Pressure actuator Diaphragm (nitrile (Buna-N))
Height 5.55 in
Depth 2.63 in
Width 3.5 in
Operating position Any position
Materials in contact with fluid Nitrile (Buna-N)
Zinc plated steel
Short-circuit protection 10 A by gL (cartridge) overload and short-circuit protection
Operating rate <= 120 cyc/mn
Mechanical durability 5000000 cycles
Repeat accuracy 4 %
Product weight 3 lb(US)
Aug 11, 2019
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Environment
Vibration resistance 2 gn conforming to IEC 68-2-6 (f = 40...150 Hz)
Shock resistance 50 gn conforming to IEC 58-2-27
Standards UL 508
CE
CSA C22.2 No 14
Product certifications CE
UL listed file E12158 CCN NKPZ and CCN NTHT
CSA LR25490 class 3211 03
NEMA degree of protection NEMA 4/4X/13 conforming to UL 50
Ambient air temperature for operation -10...185 F
Ordering and shipping details
Category 21522 - 9012 G INDUSTRIAL PRESSURE SWITCHES
Discount Schedule CP7G
GTIN 00785901025023
Nbr. of units in pkg. 1
Package weight(Lbs) 3
Returnability N
Country of origin MX
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW)
Compliant - since 1150 - Schneider Electric declaration of conformity Schnei-
der Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available
Product end of life instructions Available
California proposition 65 WARNING: This product can expose you to chemicals including:
- - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause
cancer, and
- - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause
birth defects or other reproductive harm.
- - - - - - - More information For more information go to www.p65warnings.ca.gov
Contractual warranty
Warranty period 18 months
2