Product data sheet 9013FSG2J21M4 Characteristics water pump switch 9013FS - adjustable diff. - 30-50 psi Main Range of product Square D Pumptrol Pressure sensor name 9013FS Pressure sensor size 65 psi (5...45 psi) Value of setting 30...50 psi Electrical circuit type Power circuit Product specific appli- Control electrically driven water pumps cation Quantity per set 1 Type of packing Individual Complementary Pressure sensor type Electromechanical pressure switch Controlled fluid Fresh water (-22...257 F) Adjustable range on rising pressure 20...65 psi Approximate adjustable differential 15...30 psi Destruction pressure 220 psi Pressure actuator Diaphragm Pressure switch type of operation Regulation between 2 thresholds Scale type Adjustable differential Setting Internal Local display Without Contacts type and composition 2 NC, snap action, DPST-DB, Form YY Cable entry number 2 0.88 in cable entries with 0.84 in across flats UL 508 Electrical connection Screw-clamp terminals, clamping capacity: 10 AWG Screw-clamp terminals, clamping capacity: 5.261 mm Fluid connection type 0.25 inch NPSF internal conforming to UL 508 Short-circuit protection 20 A by cartridge fuse, type gG Materials in contact with fluid Zinc plated steel or equivalent flange Nitrile (Buna-N) or equivalent rubber diaphragm Material Polypropylene cover Noryl thermoplastic resin or equivalent cover Operating position Any position Motor power kW 1.5 kW (2 hp) at 230 V AC, 1 phase 1.1 kW (1.5 hp) at 115 V AC, 1 phase 1.5 kW (2 hp) at 115 V AC, 3 phases 2.2 kW (3 hp) at 230 V AC, 3 phases 0.75 kW (1 hp) at 460 V AC, 3 phases 0.75 kW (1 hp) at 575 V AC, 3 phases 0.18 kW (0.25 hp) at 115 V DC 0.18 kW (0.25 hp) at 230 V DC Electrical durability 100000 cycles at 10 cyc/mn Mechanical durability 300000 cycles Terminal block type 4 terminals Operating rate 10 cyc/mn Ui rated insulation voltage 575 V conforming to UL 508 Product weight 1 lb(US) Repeat accuracy +/- 3 % Feb 5, 2018 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Terminals description ISO n1 L1-T1 L2-T2 Width 3.1 in Height 2.8 in Depth 3.76 in Factory modification Low pressure cut-off (AUTO-START-OFF) operates roughly 10 PSIG below cut- in Environment Standards CE UL 508 NSF ANSI 61 Annex G Ambient air temperature for operation -33...257 F Ambient air temperature for storage -33...257 F Protective treatment None NEMA degree of protection NEMA 1 conforming to UL 50 IP degree of protection IP20 conforming to IEC 60529 Product certifications UL listed file E12158 CSA file LR25490 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1150 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Download Product Environmental Product end of life instructions Available Download End Of Life Manual 2