Product data sheet ATV320U04M3C Characteristics Variable speed drive, Altivar Machine ATV320, 0.37 kW, 200...240 V, 3 phases, compact Main Range of Product Altivar Machine ATV320 Product or Component Variable speed drive Type Product Specific Complex machines Application Variant Standard version Format of the drive Compact Mounting Mode Wall mount Communication Port Modbus serial Protocol CANopen Option card Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, Profinet Communication module, Ethernet Powerlink Communication module, EtherNet/IP Communication module, DeviceNet Us rated supply 200...240 V - 15...10 % voltage Nominal output current 3.3A Motor power kW 0.37kW heavy duty EMC filter Without EMC filter IP degree of protection IP20 Complementary Discrete input number 7 Discrete input type STO safe torque off, 24 V DC1.5 kOhm DI1...DI6 logic inputs, 24 V DC 30 V) DI5 programmable as pulse input 030kHz, 24 V DC 30 V) Discrete input logic Positive logic (source) Negative logic (sink) Discrete output number 3 Discrete output type Open collector DQ+ 01kHz 30 V DC 100mA Open collector DQ- 01kHz 30 V DC 100mA Analogue input number 3 Analogue input type AI1 voltage 0...10 V DC 30 kOhm 10 bits AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits Analogue output number 1 Analogue output type Software-configurable current AQ1 0...20 mA 800Ohm 10 bits Software-configurable voltage AQ1 0...10 V DC 470Ohm 10 bits Relay output type Configurable relay logic R1A 1 NO 100000cycles Configurable relay logic R1B 1 NC 100000cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO 100000cycles Configurable relay logic R2C Maximum switching current Relay output R1A, R1B, R1C resistive, cos phi = 1 3A 250 V AC Relay output R1A, R1B, R1C resistive, cos phi = 1 3A 30 V DC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7ms 2A 250 V AC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7ms 2A 30 V DC Relay output R2A, R2C resistive, cos phi = 1 5A 250 V AC Relay output R2A, R2C resistive, cos phi = 1 5A 30 V DC Jan 18, 2022 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C 5mA 24 V DC Method of access Slave CANopen 4 quadrant operation possible True Asynchronous motor control profile Voltage/Frequency ratio, 5 points Flux vector control without sensor, standard Voltage/Frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points Synchronous motor control profile Vector control without sensor Maximum output frequency 0.599kHz Transient overtorque 170200% of nominal motor torque Acceleration and deceleration ramps Linear U S CUS Ramp switching Acceleration/Deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Motor slip compensation Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points) Switching frequency 2...16 kHz adjustable 4...16 kHz with derating factor Nominal switching frequency 4 kHz Braking to standstill By DC injection Brake chopper integrated True Line current 3.6A 200 V heavy duty) 3.0A 240 V heavy duty) Maximum Input Current per Phase 3.6A Maximum output voltage 240V Apparent power 1.2kVA 240 V heavy duty) Network Frequency 50-60 Hz Relative symmetric network frequency tolerance 5% Prospective line Isc 5kA Base load current at high overload 8.0A Power dissipation in W Self-cooled 27.0W 200 V 4 kHz With safety function Safely Limited Speed (SLS) True With safety function Safe brake management (SBC/ False SBT) With safety function Safe Operating Stop (SOS) False With safety function Safe Position (SP) False With safety function Safe programmable logic False With safety function Safe Speed Monitor (SSM) False With safety function Safe Stop 1 (SS1) True With sft fct Safe Stop 2 (SS2) False With safety function Safe torque off (STO) True With safety function Safely Limited Position (SLP) False With safety function Safe Direction (SDI) False Protection type Input phase breaks drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection drive Width 2.83in (72.0mm) Height 5.63in (143.0mm) Depth 5.04in (128.0mm) Net Weight 1.98lb(US) (0.9kg) 2