Mini control relays K control relays Control circuit : a.c. or d.c. ccc cc or References aaa aa Mini control relays - Mounted on 35 mm rail or 4 mm screw fixing. - Screws in open ready-to-tighten position. Control circuit Type of Auxiliary Basic reference. Weight 1 connection contacts Complete with code indicating control circuit voltage (2) Supply Consumption N/O N/C kg a.c. 4.5 VA Screw clamp 4 CA2-KN40ii 0.180 31 CA2-KN31ii 0.180 22 CA2-KN22ii 0.180 Faston 4 CA2-KN407ii 0.180 1 x 6.35 3 1 CA2-KN317ii 0.180 or 2 x 2.8 2 2 CA2-KN227ii 0.180 Solder pins 4 CA2-KN405ii 0.210 for printed 3 1 CA2-KN315ii 0.210 circuit board 2 2 CA2-KN225ii 0.210 d.c. 2.4 W Screw clamp 4 CA3-KN40ii 0.225 31 CA3-KN31ii 0.225 22 CA3-KN22ii 0.225 CA2-KN40ii Faston 4 CA3-KN407ii 0.225 1 x 6.35 3 1 CA3-KN317ii 0.225 or 2 x 2.8 2 2 CA3-KN227ii 0.225 Solder pins 4 CA3-KN405ii 0.255 for printed 3 1 CA3-KN315ii 0.255 circuit board 2 2 CA3-KN225ii 0.255 Low consumption mini control relays - Compatible with PLC outputs. - LED operation indicator incorporated. - Wide range coil (0.7...1.30 Uc), suppressor fitted as standard. - Mounting on 35 mm rail or 4 mm screw fixing. - Screws in open ready-to-tighten position. d.c. 1.5 W Screw clamp 4 CA4-KN40iii 0.235 CA3-KN407ii 31 CA4-KN31iii 0.235 22 CA4-KN22iii 0.235 Faston 4 CA4-KN407iii 0.235 1 x 6.35 3 1 CA4-KN317iii 0.235 or 2 x 2.8 2 2 CA4-KN227iii 0.235 Solder pins for 4 CA4-KN405iii 0.265 printed circuit 3 1 CA4-KN315iii 0.265 board 2 2 CA4-KN225iii 0.265 (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). CA2-K mini control relays (0.8...1.15 Uc) (0.85...1.1 Uc) Volts c 12 24 36 42 48 110 127 220/ 230 230/ 380/ 400 400/ 440 500 660/ 50/60 Hz 230 240 400 415 690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 CA3-K mini control relays (0.8...1.15 Uc) Volts a 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3. CA4-K, low consumption mini control relays (wide range coil: 0.7...1.3 Uc) Volts a 12 24 48 72 Code JW3 BW3 EW3 SW3 Mini control relays CA2-K, CA3-K, CA4-K On panel On printed circuit board LA1-K 4x4 8,65 == = A1 = 35 = 10x1,3 45 A2 31 57 45 1/170 Te 58 ==50 58 50 53Mini control relays K control relays Instantaneous and time delay auxiliary contact blocks References Instantaneous auxiliary contact blocks Clip-on front mounting, 1 block per mini control relay Type of connection Composition Reference Weight 1 N/O N/C kg Screw clamp 2 LA1-KN20 0.045 2 LA1-KN02 (1) 0.045 11 LA1-KN11 (2) 0.045 4 LA1-KN40 (3) 0.045 31 LA1-KN31 (3) 0.045 22 LA1-KN22 (3) 0.045 13 LA1-KN13 (4) 0.045 LA1-KN40 4 LA1-KN04 (5) 0.045 Faston 2 LA1-KN207 0.045 1 x 6.35 2 LA1-KN027 0.045 or 2 x 2.8 1 1 LA1-KN117 0.045 4 LA1-KN407 (3) 0.045 31 LA1-KN317 (3) 0.045 22 LA1-KN227 (3) 0.045 13 LA1-KN137 (3) 0.045 4 LA1-KN047 (3) 0.045 (1) Cannot be used on control relays : CA4-KN22, CA4-KN31. (2) Cannot be used on control relays : CA4-KN22. (3) Cannot be used on control relays : CA4-KNiiiii. (4) Cannot be used on control relays : CA3-KN22, CA4-KNiiiii. (5) Cannot be used on control relays : CA3-KN22, CA3-KN31, CA4-KNiiiii. Electronic time delay contact blocks - Relay output with common point changeover contact, 2 A maximum - Control voltage : c or a 24...48 V, c 110...240 V, 0.85...1.1 Uc - Maximum switching capacity : 250 VA or 150 W - Operating temperature : - 10...+ 60 C - Reset time : 1.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, 1 block per mini control relay Voltage Type Timing Composition Reference Weight range V S C/O kg c or a 24...48 On-delay 1...30 1 LA2-KT2E 0.040 c 110...240 On-delay 1...30 1 LA2-KT2U 0.040 Electronic time delay blocks LA2-KT On mini control relays LA2-KT 34 38 34 57 1/171 Te 27 58