Product Data Sheet HU362 Safety Switch , 60A, 600V, Non-Fusible, Heavy Duty, 3-Pole List Price 325.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Technical Characteristics Depth 6.38 Inches Height 17.50 Inches Width 9.00 Inches Action Single Throw Ampere Rating 60A Approvals UL Listed Catalog Reference Number 3100CT9801 Electrical Interlock None Enclosure Material Steel Enclosure Rating NEMA 1 Enclosure Type General Purpose (Indoor) Factory Installed Neutral No Disconnect Type Non-Fusible Terminal Type Lugs Mounting Type Surface Wire Size 12 to 2 AWG(Al) or 14 to 2 AWG(Cu) Type of Duty Heavy Duty Short Circuit Current Rating 200kA(max) Number of Poles 3-Pole Maximum Voltage Rating 600V Shipping and Ordering Category 00008 - Safety Switch, Heavy Duty, 2 & 3 Pole, 30-200 Amp, Indoor Discount Schedule DE1 Article Number 785901505808 Package Quantity 1 Weight 14.8 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/17/2009 08:05:13 2009 Schneider Electric. All rights reserved. 1SAFETY SWITCHES 3 Heavy Duty Safety Switches www.schneider-electric.us Table 3.10: 600 VoltSingle Throw Non-Fusible NEMA 4, 4X, 5 a Horsepower Ratings 304 Stainless Steel NEMA 12K NEMA 12, 3Rb (Max.) c NEMA 3R (for 316 stainless, see With Without NEMA 1 Volts ac Rainproof page 3-7) Knockouts Knockouts Rating Indoor System (Bolt-on Hubs, page 3-11) Dust tight, Watertight (Watertight Hubs, (Watertight Hubs, (A) dcd Corrosion Resistant page 3-11) page 3-11) 240 480 600 (Watertight Hubs, page 3-11) Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 1 3 1 3 1 3 250 600 2-Wire (2 Blades)600 Vac, 600 Vdc 30 60 Use three-wire devices for two-wire applications. 100 200 400 HU265 2750.00 HU265R 3764.00 HU265DS 12812.00 HU265AWK 3212.00 50 50 600 HU266 4896.00 HU266R 7533.00 HU266DS 18455.00 HU266AWK 5408.00 50 50 800 HU267 7467.00 HU267Re 12884.00 HU267AWK 12957.00 50 50 50 50 1200 HU268 10226.00 HU268Re 17393.00 HU268AWK 17522.00 50 50 50 50 3-Wire (3 Blades)600 Vac, 600 Vdc 30 HU361 279.00 HU361RB 488.00 HU361DS 2520.00 HU361A 689.00 HU361AWK 647.00 5 10 7-1/2 20 10 30 5 15 30 HU361EIf 638.00 HU361RBEIf 846.00 HU361DSEIf 2480.00 HU361AEIf 1047.00 HU361AWKEIf 1007.00 5 10 7-1/2 20 10 30 5 15 30 HU3612g 369.00 HU3612RBg 638.00 HU3612Ag 710.00 HU3612AWKg 666.00 5 10 7-1/2 20 10 30 5 15 60 HU362 488.00 HU362RB 876.00 HU362DS 2520.00 HU362A 875.00 HU362AWK 833.00 10 20 25 50 30 60 10 30 60 HU362DSEIf 2972.00 10 20 25 50 30 60 10 30 100 HU363 783.00 HU363RB 1226.00 HU363DS 5102.00 HU363A 1265.00 HU363AWK 1194.00 20 40 40 75 40 100 20 50 200 HU364 1209.00 HU364RB 1485.00 HU364DS 6960.00 HU364A 1697.00 HU364AWK 1604.00 15 60 50 125 50 150 40 50 400 HU365 2804.00 HU365R 3840.00 HU365DS 14294.00 HU365AWK 4023.00 125 250 350 50 50 600 HU366 4992.00 HU366R 7683.00 HU366DS 19062.00 HU366AWK 6711.00 200 400 500 50 50 800 HU367 9978.00 HU367Re 13050.00 HU367AWK 13097.00 50 250 50 500 50 500 50 50 1200 HU368 13421.00 HU368Re 17867.00 HU368AWK 17940.00 50 250 50 500 50 500 50 50 4-Wire (4 Blades)600 Vac, 600 Vdck 2 3 2 3 2 3 30 HU461h 827.00 HU461DS 2586.00 HU461AWKi 915.00 10 10 20 20 25 30 10j 15j 60 HU462h 914.00 HU462DS 3027.00 HU462AWK 1008.00 20 20 40 50 50 60 10 30 100 HU463h 1647.00 HU463DS 7401.00 HU463AWK 1791.00 30 40 50 75 50 75 20 30 200 HU464h 2399.00 HU464DS 11244.00 HU464AWK 2832.00 50 60 50 125 50 150 40 50 400 HU465 5201.00 HU465AWK 5672.00 125 250 350 50 50 600 HU466 9072.00 200 400 500 50 50 6-Wire (6 Blades)600 Vack 3 3 3 30 HU661DS 11903.00 HU661AWKl 3357.00 10 20 30 60 HU662DS 13254.00 HU662AWKl 3884.00 20 50 60 100 HU663DS 20643.00 HU663AWKl 4793.00 40 75 75 200 HU664DS 28316.00 HU664AWKl 10538.00 60 125 150 a Complete rating is NEMA 3, 3R, 4, 4X, 5 and 12. b Also suitable for NEMA 3R application by removing drain screw from bottom endwall. c Refer to page 7-32 for additional motor application data. d For switching dc, use two switching poles. e Suitable for NEMA 5 applications with drain screw installed. f Switches with EI suffix are stocked with factory-installed electrical interlocks with one normally-open and one normally-closed contact. g Use 60 A enclosure accessories, including electrical interlocks. h No knockouts are provided. i Check series number on switch for correct accessory. See page 3-15. j HU461AWK (Series E1) is rated 5 hp 250 Vdc, 10 hp 600 Vdc. k Not suitable for use as service equipment. l One enclosure for NEMA 1, 3, 3R or 12 applications. UL Listed. UL Listed Maximum Short Circuit Current RatingsAC only Non-Fusible Safety Switches NOTE: Consult the wiring diagram of the switch to verify the Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used in conjunction with an non-fusible safety switch when UL Listed short circuit current rating. there is up to 10 kA short circuit current available (see table below). Above 10 kAWhen applied on systems with greater than 10 kA short circuit current available, the UL Listed short circuit current rating for Table 3.11: Fusible Safety Switches Square D non-fusible switches is based upon the switch being used in For the short circuit current rating, refer to the table below. conjunction with fuses or Square D circuit breakers or Mag-Gard motor Heavy Duty UL Listed UL Listed Short Circuit circuit protectors. Safety Switch Type Fuse Class Current Ratings H, K 10 kA Table 3.12: Non-Fusible Safety Switches Fusible R, J, L 200 kAm 3-Phase Heavy Duty Switch Rating Fuse or Circuit m On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when protected by Safety Switch Type (A) n Breaker Typeo Class J or R fuses. 240 Vac 480 Vac 600 Vac Any brand circuit breaker Up to 10 kA All H, K R,T,J.L 200 kA 200 kA 200 kA 30100 H p 65 kA 35 kA 25 kA 30100 FA 14 kA 14 kA 14 kA Non-Fusible 30100 FH 18 kA 18 kA 18 kA Switches 200 H, J p 65 kA 35 kA 25 kA 200 KA 400 LA 22 kA 22 kA 22 kA 600 MA 200 KH 400 LH 25 kA 25 kA 25 kA 600 MH n Applies to NEMA 1, 3R, 4X stainless, 12 switches. o Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. p All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Ratings. 2009 Schneider Electric 3-6 Discount DE1 Schedule All Rights Reserved