Product data sheet LUB12 Characteristics TeSys U, power base, 12 A, screw clamps control Product availability: Stock - Normally stocked in distribution facility Main Range TeSys Product name TeSys U Device short name LUB Product or component Non reversing power base type Device application Motor Poles description 3P Suitability for isolation Yes Ith conventional free 12 A air thermal current Utilisation category AC-41 AC-44 AC-43 Uc control circuit volt- 110...220 V DC age 110...240 V AC 50/60 Hz 24 V AC 50/60 Hz 24 V DC 48 V AC 50/60 Hz 48...72 V DC Complementary Auxiliary contact composition 1 NO + 1 NC Auxiliary contacts type Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1 System Voltage 230 V 440 V 500 V 690 V Network frequency 40...60 Hz Ie rated operational current 12 A at <= 440 V 12 A at 500 V 9 A at 690 V Ics rated service breaking capacity 10 kA 500 V 4 kA 690 V 50 kA 230 V 50 kA 440 V Typical current consumption 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 150 mA at 24 V DC I maximum while closing with LUCM 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 70 mA at 24 V DC I rms sealed with LUCM Safety reliability level B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Operating time 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit 75 ms closing with LUCM control circuit Mechanical durability 15000000 cycles Operating rate 60 cyc/mn Ui rated insulation voltage 600 V conforming to CSA C22.2 No 14 600 V conforming to UL 508 690 V conforming to IEC 60947-1 3 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-6-2 Safe separation of circuit 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conform- ing to IEC 60947-1 appendix N Connections - terminals Power circuit: screw clamp terminals 2 cable 0...0.01 in (1.5...6 mm) - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 1 cable 0...0 in (0.34...1.5 mm) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable 0...0 in (0.75...1.5 mm) - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 1 cable 0...0 in (0.75...1.5 mm) - cable stiffness: rigid - without cable end Control circuit: screw clamp terminals 2 cable 0...0 in (0.34...1.5 mm) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 2 cable 0...0 in (0.75...1.5 mm) - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 2 cable 0...0 in (0.75...1.5 mm) - cable stiffness: rigid - without cable end Power circuit: screw clamp terminals 1 cable 0...0.02 in (1...10 mm) - cable stiff- ness: rigid - without cable end Power circuit: screw clamp terminals 1 cable 0...0.01 in (1...6 mm) - cable stiff- ness: flexible - with cable end Power circuit: screw clamp terminals 1 cable 0...0.02 in (2.5...10 mm) - cable stiffness: flexible - without cable end Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiff- ness: flexible - with cable end Power circuit: screw clamp terminals 2 cable 0...0.01 in (1...6 mm) - cable stiff- ness: rigid - without cable end Tightening torque Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flat Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1 Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flat Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2 Width 1.77 in (45 mm) Height 5.71 in (145 mm) Depth 4.96 in (126 mm) Product weight 1.98 lb(US) (0.9 kg) Environment Heat dissipation 2 W control circuit with LUCA, LUCB, LUCC, LUCD 1.7 W control circuit with LUCM Immunity to microbreaks 3 ms Immunity to voltage dips 70 % 500 ms conforming to IEC 61000-4-11 Product certifications CCC CSA DNV BV ATEX ASEFA GL ABS GOST UL LROS (Lloyds register of shipping) Standards CSA C22.2 No 14 type E EN 60947-6-2 IEC 60947-6-2 UL 508 type E with phase barrier 2