Product data sheet RE17RLMU Characteristics asymmetrical flashing relay - 1 s..100 h - 24..240 V AC - 1 OC Product availability: Stock - Normally stocked in distribution facility Main Range of product Zelio Time Product or component Modular timing relay type Discrete output type Relay Width 0.69 in (17.5 mm) Device short name RE17R Time delay type L Li Time delay range 6...60 min 1...10 h 1...10 min 0.1...1 s 10...100 h 6...60 s 1...10 s Nominal output current 8 A Complementary Contacts type and composition 1 C/O Contacts material Cadmium free Control type Selector switch on front panel Us rated supply voltage 24...240 V AC at 50/60 Hz 24 V DC Voltage range 0.85...1.1 Us Supply frequency 50...60 Hz (+/- 5 %) Release of input voltage 10 V Connections - terminals Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm AWG 20...AWG 12 (solid) without cable end Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm AWG 20...AWG 14 (solid) without cable end Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm AWG 24...AWG 14 (flexible) with cable end Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm AWG 24...AWG 16 (flexible) with cable end Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift +/- 0.05 %/C Voltage drift +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 C conforming to IEC 61812-1 Control signal pulse width 100 ms with load in parallel typical 30 ms typical Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Reset time 120 ms on de-energisation typical On-load factor 100 % Power consumption in VA 0...32 VA at 240 V AC Power consumption in W <= 0.6 W at 24 V DC Minimum switching current 10 mA at 5 V DC Maximum switching current 8 A AC/DC Maximum switching voltage 250 V AC Breaking capacity <= 2000 VA Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Operating frequency 10 Hz Electrical durability 100000 cycles resistive load (8 A at 250 V AC maximum) Mechanical durability 10000000 cycles Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 Uimp rated impulse withstand voltage 5 kV (1.2/50 s) Power on delay < 100 ms Marking CE Creepage distance 4 kV/3 conforming to IEC 60664-1 Safety reliability data MTTFd = 296.8 years B10d = 270000 Mounting position Any position in relation to normal vertical mounting plane Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Local signalling LED indicator on steady: relay energised, no timing in progress LED indicator flashing: timing in progress (80 % ON and 20 % OFF) Product weight 0.15 lb(US) (0.07 kg) Environment Immunity to microbreaks <= 20 ms Standards EN 61000-6-4 IEC 61812-1 EN 61000-6-3 2004/108/EC EN 61000-6-1 2006/95/EC EN 61000-6-2 Product certifications GL CULus CSA Ambient air temperature for storage -22...140 F (-30...60 C) Ambient air temperature for operation -4...140 F (-20...60 C) IP degree of protection IP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 Vibration resistance 20 m/s (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 Relative humidity 93 % without condensation conforming to IEC 60068-2-30 Electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3 Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3 Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3 Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3 Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3 1.2/50 s shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3 1.2/50 s shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3 Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3 Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11 Conducted and radiated emissions conforming to EN 55022 class B Ordering and shipping details Category 22370 - RE, RM MISC TIMERS & COUNTERS Discount Schedule CP2 GTIN 00785901376361 Nbr. of units in pkg. 1 Package weight(Lbs) 0.17000000000000001 2