Product data sheet RE8RA31FUTQ Characteristics Optimum industrial timing relay, Zelio Time, 0.3...30 s, type C, 110...240 V AC, 1 C/O Main Range of Product Zelio Time Product or Component Optimum industrial timing relay Type Component name RE8 Time delay type C Time delay range 0.3...30 s Sale per indivisible 10 quantity Complementary Discrete output type Relay Contacts material 90/10 silver nickel contacts Width pitch dimension 0.89in (22.5mm) Us rated supply voltage 110...240 V AC 50/60 Hz Voltage range 0.9...1.1 Us Connections - terminals Screw terminals, 2 x 1.5 mm flexible with cable end Screw terminals, 2 x 2.5 mm flexible without cable end Tightening torque 5.319.74lbf.in (0.61.1N.m) Setting accuracy of time delay +/- 20 % of full scale Repeat accuracy < 1 % Voltage drift < 2.5 %/V Temperature drift < 0.2 %/C Minimum pulse duration 26ms Reset time 50ms Maximum switching voltage 250V Mechanical durability 20000000cycles Ith conventional free air thermal current 8A Maximum Ie rated operational current 2A DC-13 24 V 158F (70C) IEC 60947-5-1/1991 2A DC-13 24 V 158F (70C) VDE 0660 3A AC-15 24 V 158F (70C) IEC 60947-5-1/1991 3A AC-15 24 V 158F (70C) VDE 0660 0.1A DC-13 250 V 158F (70C) IEC 60947-5-1/1991 0.1A DC-13 250 V 158F (70C) VDE 0660 0.2A DC-13 115 V 158F (70C) IEC 60947-5-1/1991 0.2A DC-13 115 V 158F (70C) VDE 0660 Minimum switching capacity 10mA 12 V Input voltage 110...240 V Y1 Maximum switching current 10mA Y1) Input compatibility 2-wire sensors DC with leakage current < 1 mA <164.04ft (50m) Y1 Marking CE Overvoltage category III IEC 60664-1 Ui rated insulation voltage 250V IEC 300V CSA Supply disconnection value > 0.1 Uc Operating position Any position without derating Surge withstand 2kV IEC 61000-4-5 level 3 Power consumption in VA 1.8VA 110 V 8.5VA 240 V Jan 19, 2022 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Terminal description (15-16-18)OC ON (A1-A2)CO (Y1)UNUSED Height 3.07in (78mm) Width 0.89in (22.5mm) Depth 3.15in (80mm) Net Weight 0.24lb(US) (0.11kg) Environment Immunity to microbreaks 3ms Standards EN/IEC 61812-1 Product Certifications UL CSA GL Ambient Air Temperature for Storage -40185F (-4085C) Ambient air temperature for operation -4140F (-2060C) Relative humidity 1585% 3K3 IEC 60721-3-3 Vibration resistance 0.35 mm 1055Hz)IEC 60068-2-6 IP degree of protection IP20 terminals) IP50 casing) Pollution degree 3 IEC 60664-1 Dielectric test voltage 2.5kV Non-dissipating shock wave 4.8kV Resistance to electromagnetic fields 9.14V/m (10V/m) IEC 61000-4-3 level 3 Resistance to fast transients 2kV IEC 61000-4-4 level 3 Disturbance radiated/conducted CISPR 11 group 1 - class A CISPR 22 - class A Ordering and shipping details Category 22376-RELAYS-MEASUREMENT(RM4) Discount Schedule CP2 GTIN 00785901466550 Package weight(Lbs) 0.20lb(US) (0.091kg) Returnability No Country of origin ID Packing Units Package 1 Height 2.300dm Package 1 width 0.820dm Package 1 Length 0.850dm Contractual warranty Warranty 18 months 2