Product datasheet XALD101H29H7 Characteristics dark grey station - 1 green flush pushbutton 22 spring return 1NOStar Main Range of product Harmony XALD Product or component type Complete control station Device short name XALD Product destination For XB5 22 mm control and signalling units Control station application Start function Colour of base of enclosure Light grey RAL 7035 Colour of cover Dark grey RAL 7016 Material Polycarbonate Operator profile 1 flush push-button Operators description Green START 1 NO Control station composition 1 flush push-button green 1 NO START marking Marking location Marking on legend holder Contacts operation Slow-break Complementary Cable entry 1 knock-out for cable entry, clamping capacity: <= 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: <= 12 mm Product weight 0.157 kg Resistance to high pressure washer 7000000 Pa at 55 C, distance: 0.1 m Positive opening Without Operating travel 2.6 mm (NO changing electrical state) 4.3 mm (total travel) Operating force 3.8 N (NO changing electrical state) Mechanical durability 5000000 cycles Connections - terminals Screw clamp terminals : <= 2 x 1.5 mm with cable end conforming to EN/IEC 60947-1 Screw clamp terminals : >= 1 x 0.22 mm without cable end conforming to EN/IEC 60947-1 Tightening torque 0.8...1.2 N.m conforming to EN/IEC 60947-1 Shape of screw head Cross, Philips no 1 Cross, pozidriv No 1 Mar 09, 2017 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsSlotted, flat 4 mm Slotted, flat 5.5 mm Contacts material Silver alloy (Ag/Ni) Short circuit protection 10 A by gG cartridge fuse conforming to EN/IEC 60947-5-1 Ith conventional free air thermal 10 A conforming to EN/IEC 60947-5-1 current Ui rated insulation voltage 600 V (degree of pollution: 3) conforming to EN/IEC 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1 Ie rated operational current AC-15, A600: Ue = 120 V Ie = 6 A conforming to EN/IEC 60947-5-1 AC-15, A600: Ue = 240 V Ie = 3 A conforming to EN/IEC 60947-5-1 AC-15, A600: Ue = 600 V Ie = 1.2 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 125 V Ie = 0.55 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 250 V Ie = 0.27 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 600 V Ie = 0.1 A conforming to EN/IEC 60947-5-1 Electrical durability 1000000 cycles AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C Electrical reliability IEC 60947-5-4 < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4 < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4 Environment Protective treatment TH Ambient air temperature for storage -40...70 C Ambient air temperature for operation -40...70 C Overvoltage category Class II conforming to IEC 60536 IP degree of protection IP69 IP67 IP66 conforming to IEC 60529 IP69K NEMA degree of protection NEMA 13 NEMA 4X IK degree of protection IK03 conforming to EN 50102 Standards UL 508 EN/IEC 60947-5-1 JIS C 4520 CSA C22.2 No 14 EN/IEC 60947-1 EN/IEC 60947-5-4 EN/IEC 60947-5-5 Product certifications UL listed CSA Vibration resistance 5 gn (12...500 Hz) conforming to IEC 60068-2-6 Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 Offer Sustainability Sustainable offer status Not Green Premium product 2