Characteristics Control stations and enclosures Control station enclosures: insulated, metal and flush mounting Insulated enclosures XAP-A Material and colour Glass-reinforced polyester, coloured grey throughout Approvals Special version: CSA ENCLOSURE 4 and 5 Protective treatment Standard version: TC and TH Ambient air temperature Operation: - 25+ 70 C. Storage: - 40+ 70 C Degree of protection IP 65 conforming to IEC 529 and IP 657 conforming to NF C 20-010 Electric shock protection Class II conforming to IEC 536 and NF C 20-030 Flame resistance CSTB: M3, NF C 20-455: 850 C, IEC 92: 960 C, UL 94: VO Chemical resistance Highly resistant to acids, bases, sea water, mineral salts, all solvents, petrol, diesel, oils and greases Cable entry Undrilled, drill to suit Diecast metal enclosures XAP-M Material and colour Zinc alloy (XAP-M1, M2, M3, M4), aluminium alloy (XAP-M5). Blue paint nish Approvals Special version: CSA ENCLOSURE 4 and 5, UL ENCLOSURE 1, 3, 4 and 12K Protective treatment Standard version: TC. Special version: TH Ambient air temperature Operation: - 25+ 70 C. Storage: - 40+ 70 C Degree of protection IP 65 conforming to IEC 529 and IP 657 conforming to NF C 20-010 Electric shock protection Class I conforming to IEC 536 and NF C 20-030 Chemical resistance Special treatments on request Cable entry Tapped entries for addition of cable glands (see dimensions, page 6/14) Metal enclosures XB2-S 6 Material and colour Aluminium alloy or sheet steel. Blue paint nish Protective treatment Standard version: TC. Special version: TH Ambient air temperature Operation: - 25+ 70 C. Storage: - 40+ 70 C Degree of protection IP 54 conforming to IEC 529 and IP 547 conforming to NF C 20-010 Electric shock protection Class I conforming to IEC 536 and NF C 20-030 Chemical resistance Special treatments on request Cable entry XB2-S in aluminium alloy: tapped entries for addition of cable glands (see dimensions, page 6/14) XB2-S in sheet steel: undrilled, drill to suit Flush mounting enclosures XAP-E Material and colour Anodised aluminium front plate. Insulated protective rear cover Protective treatment Standard version: TC and TH Ambient air temperature Operation: - 25+ 70 C. Storage: - 40+ 70 C Degree of protection IP 65 conforming to IEC 529 and IP 657 conforming to NF C 20-010 Electric shock protection Class I conforming to IEC 536 and NF C 20-030 Chemical resistance High degree of resistance to organic acids, diluted mineral acids, salts, alcohol, acetone, chloride and uoride solvents, oils and petrol Cable entry Through rear cover: knock-out cable entries References: Dimensions: pages 6/11 to 6/13 pages 6/14 and 6/15 Schneider Electric 6/10 References Control stations and enclosures Control station enclosures: insulated, metal and flush mounting With cut-outs for 22 mm control and signalling units Insulated enclosures, glass-reinforced polyester (usable depth 83 mm) Description Front face Number Number of rows Reference Weight dimensions of vertical horizontal mm cut-outs kg Without 85 x 146 1 1 1 XAP-A1110 0.470 hinges XAP-A1104 21 2 XAP-A1120 0.450 42 2 XAP-A1104 0.460 85 x 226 8 2 4 XAP-A2108 0.580 151 x 241 16 4 4 XAP-A3116 0.820 XAP-A2108 With 151 x 241 16 4 4 XAP-A4116 0.850 hinges Earthing For XAP-A1110 XAP-Z110 0.080 plates Sheet steel with earth screw For XAP-A1120 XAP-Z120 0.070 For XAP-A1104 XAP-Z104 0.070 6 For XAP-A2108 XAP-Z208 0.110 XAP-A3116 For XAP-A3116 and A4116 XAP-Z316 0.160 Elbowed metal enclosures for mounting on vertical support Description Number of Reference Weight cut-outs kg Elbowed enclosure 1 DWG-1 0.465 DWG-p metal Lid: light grey (RAL 7035) 2 DWG-2 0.545 Base: dark grey (RAL 7016) 3 DWG-3 0.725 4 DWG-4 0.725 5 DWG-5 0.790 6 DWG-6 0.990 7 DWG-7 0.990 Other versions Insulated and metal control station enclosures with cut-outs for 30 mm control and signalling units. Protective guards and xing lugs for diecast metal enclosures. Insulated and metal control station enclosures pre-tted with 22 units. Adjustable oor mounting pedestal (790 to 1143 mm) for sheet steel enclosures. Please call our Customer information centre on 0870 608 8 608. Characteristics: Dimensions: page 6/10 page 6/14 Schneider Electric 6/11