Product datasheet
XB4BW35G5
Characteristics
Main
Range of product Harmony XB4
Product or component type Illuminated push-button
Device short name XB4
Bezel material Chromium plated metal
Fixing collar material Zamak
Mounting diameter 0.87 in (22 mm)
Sale per indivisible quantity 1
Head type Standard
Shape of signaling unit head Round
Type of operator Spring return
Operator profile Orange flush
Operator additional information With plain lens
Contacts type and composition 1 NO + 1 NC
Contact operation Slow-break
Connections - terminals Screw clamp terminals: <= 2 x 1.5 mm with cable
end conforming to EN/IEC 60947-1
Screw clamp terminals: 1 x 0.22...2 x 2.5 mm
without cable end conforming to EN/IEC 60947-1
Light source Protected LED
Bulb base Integral LED
[Us] rated supply voltage 110...120 V AC 50/60 Hz
Complementary
Height 1.85 in (47 mm)
Width 1.18 in (30 mm)
Depth 3.98 in (101 mm)
Terminals description ISO n1 (13-14)NO
(21-22)NC
Product weight 0.21 lb(US) (0.097 kg)
Resistance to high pressure washer 1015.26 psi (7000000 Pa) at 131 F (55 C),distance: 0.1 m
Contacts usage Standard contacts
Positive opening With positive opening conforming to EN/IEC 60947-5-1 appendix K
Operating travel 0.06 in (1.5 mm) (NC changing electrical state)
0.1 in (2.6 mm) (NO changing electrical state)
0.17 in (4.3 mm) (total travel)
Operating force 3.5 N (NC changing electrical state)
3.8 N
Mechanical durability 10000000 cycles
Tightening torque 7.08...10.62 lbf.in (0.8...1.2 N.m) conforming to EN 60947-1
Shape of screw head Cross head compatible with Philips no 1 screwdriver
Cross head compatible with pozidriv No 1 screwdriver
Slotted head compatible with flat 4 mm screwdriver
Slotted head compatible with flat 5.5 mm screwdriver
Contacts material Silver alloy (Ag/Ni)
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1 / 3
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate: <= 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate: <= 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: <= 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
Electrical reliability < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
< 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4
Signalling type Steady
Supply voltage limits 100...132 V AC
Current consumption 14 mA
Service life 100000 h at rated voltage and 25 C
Surge withstand 1 kV conforming to IEC 61000-4-5
Device presentation Complete product
Environment
protective treatment TH
ambient air temperature for storage -40...158 F (-40...70 C)
ambient air temperature for operation -40...158 F (-40...70 C)
electrical shock protection class Class I conforming to IEC 60536
IP degree of protection IP67
IP66 conforming to IEC 60529
IP69K
IP69
NEMA degree of protection NEMA 13
NEMA 4X
IK degree of protection IK06 conforming to IEC 50102
standards EN/IEC 60947-1
EN/IEC 60947-5-1
EN/IEC 60947-5-4
EN/IEC 60947-5-5
JIS C 4520
UL 508
CSA C22.2 No 14
product certifications BV
CSA
DNV
GL
LROS (Lloyds register of shipping)
RINA
UL listed
vibration resistance 5 gn (f = 2...500 Hz) conforming to IEC 60068-2-6
shock resistance 30 gn (duration = 18 ms) half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) half sine wave acceleration conforming to IEC 60068-2-27
resistance to fast transients 2 kV conforming to IEC 61000-4-4
resistance to electromagnetic fields 9.14 V/yd (10 V/m) conforming to IEC 61000-4-3
resistance to electrostatic discharge 6 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
electromagnetic emission Class B conforming to IEC 55011
Offer Sustainability
WARNING: This product can expose you to chemicals WARNING: This product can expose you to chemicals including:
including:
Lead and lead compounds, which is known to the State Lead and lead compounds, which is known to the State of California to cause cancer
of California to cause cancer and birth defects or other and birth defects or other reproductive harm.
reproductive harm.
For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov
2 / 3